Callout 1 of 3
Ridges over St Paul's church and The Vicarage
Anyone surveying roofs in Parkend meets three listed buildings by name. St Paul's church carries a Grade II listing (Historic England list entry 1186362, listed on 12 December 1953). The Vicarage is Grade II too (list entry 1288800), and Dean Field Studies Centre (list entry 1213931) shares that grade and the listing date of 24 September 1984. A ridge on a listed roof forms part of the building's character, so we give it more care than a routine patch would get, and the survey photographs show the caps from both sides.
The ridge is the row of capping tiles that sits along the apex of a pitched roof. Where those caps are bedded in mortar, a crack in the bed is the first sign of trouble: water gets under the cap, frost works at it, and the cap starts to rock. Marley, the tile maker, states that "Installing to BS 5534 isn't required by law" and adds that the 2015 amendments "made it clear that mortar could no longer be relied upon as the only means of securing the roof covering". For that reason a rebedded ridge gets mortar and a mechanical fixing under each cap. BS 8612 is the standard for dry-fix ridges, in which a full mortar bed gives way to clips and screws.
Consent is the first question on a listed roof. Section 7 of the Planning (Listed Buildings and Conservation Areas) Act 1990 asks for it where works "would affect its character as a building of special architectural or historic interest", and a different ridge material could do exactly that. For a listed house, the question goes to Forest of Dean District Council. St Paul's is a different case. It is an Anglican church that still holds weekday services, so work on its roof sits with the diocese's faculty system rather than with the council, and that would change only if it closed for worship. Pricing it therefore starts with a call to the parish.
An unlisted house nearby is simpler. We lift the caps one at a time, look at what lies beneath, and send a photograph of every cap that has lost its grip. Each picture is labelled with the cap's position, so the repair list and the pictures match. Where only the mortar has failed, rebedding is the answer and we recommend it. Our roof repairs page covers the small jobs that do not need a full scaffold.
What the ridge survey covers at Parkend
- Caps that rock under a hand
- Bed mortar cracked or fallen away
- A clip or screw under every cap
- The end cap at each gable
- The list entry, where the building is listed
On a listed roof, the consent question comes before the repair.