Callout 1 of 3
Roof windows and rooflights in a Longford loft
A loft that needs light starts with a hole in the roof, and a hole in the roof starts with the numbers. Under AD L 2021, Table 4.2 gives the figures for new fabric in an existing dwelling: a roof 0.15, a window at 1.4 or WER Band B (a Window Energy Rating), with rooflights at 2.2 W/(m²·K). The note to the window row reads "Including roof windows and curtain walling". The window row includes roof windows, so a roof window takes 1.4 or WER Band B, and 2.2 belongs to rooflights alone. From 24 March 2027 AD L 2026 takes over, with the same values in Table 3.2.
Windows are counted differently from roofs. The Planning Portal's envelope test, the one that decides whether a re-roof needs an application in England, counts "walls, floor, roof, windows, door, roof windows and roof-lights" in the total, and its limit is "Less than 25 per cent of the total 'building envelope'". A new roof window affects part of the roof and part of the envelope, so it counts towards both measures. Regulation 2 of the Building Regulations 2010 treats a roof as a thermal element and leaves glazing set into it outside the term, so each roof window carries a limit of its own.
A rooflight set into a flat roof is a different product from a roof window. Its 2.2 figure is the limit for glazing in a roof, and the kerb around it has to be formed in the roof deck and covered by the membrane, so the roof is opened first and the glass comes last. BS 6229:2025 is current for flat roofs with flexible coverings, and NFRC reports a minimum 1:80 finished fall across the rest of the surface, which the rooflight must not disturb.
Cutting the opening is the structural part. A roof window sits between rafters, and a wider opening means trimming a rafter and fixing a header across, with the timbers either side carrying the load. That is why the loft is surveyed before any window is ordered. Flashings follow: a kit made for the covering, whether tile, slate or stone, and lead dressed by hand where a kit does not fit. Our roof windows and skylights page covers fitting, and the planning guide for roof windows sets out the planning tests in England, so read it before you settle on a size or a position.
Windows and the roof's insulation
Does a roof window count as part of the roof's insulation?
No. In the Building Regulations 2010 a thermal element is a wall, floor or roof, and glazing in a roof falls outside it. A roof window has its own limit in AD L, and the roof around it has another.
Choosing the window is the easy part; the opening is where the work lies.















