In brief
The slate producer Cupa says BS 5534:2014+A2:2018 "also indicates that the minimum roof pitch for natural slate is 20 degrees in the case of a project situated in an area with moderate exposure and with a slate 500mm long and a 115mm overlap". So 20 degrees is a floor with three conditions, not a general rule. A flatter roof, a harsher site or a shorter slate each calls for a separate answer from the slate supplier.
The Cupa sentence and what each condition means
The figure of 20 degrees is quoted all over the internet without its conditions, which is how it gets misused. Cupa's own sentence has three, and they work together:
- Moderate exposure. How exposed a site is to wind-driven rain is judged for the particular site, by the supplier or designer, and it can change from one side of a hill to the other.
- A slate 500 mm long. A shorter slate gives a different result.
- A 115 mm overlap. The overlap is the stretch of each slate hidden beneath the course higher up.
When all three hold, Cupa says 20 degrees is the lowest pitch for natural slate. When one does not, the sentence says nothing, and the figure must come from the slate supplier for that slate on that roof. A gap in the conditions is a reason to ask, not to round the number down.
The sentence also depends on a standard. BS 5534 is the standard behind roof slating and tiling, and Marley, the tile maker, notes that installing to it is not required by law. We follow the manufacturer's data because it is specific to the product on your roof.
Why 20 degrees is not the whole answer
Pitch means the incline of a slope, read from level ground upward. A roof at exactly 20 degrees is already shallow, and one a little under it falls outside the sentence altogether. The table sets out what the sentence assumes, and it adds the hook limit that Cupa states separately, because the two can be read together.
| Condition | Value in the sentence |
|---|---|
| Exposure | Moderate |
| Slate length | 500 mm |
| Overlap | 115 mm |
| Fixing | No hooks below 25 degrees |
That last row comes from a different Cupa statement, which rules hooks out of any slope pitched under 25 degrees. So a slate roof between 20 and 25 degrees is possible on the figures, but it cannot rely on hooks. Our page on slate hooks on a low pitch deals with that, and slate pitch and headlap covers how the overlap is set.
On a survey we read each slope with a level, as a porch, a dormer cheek or an extension may sit at another angle from the main roof.
How slate compares with other coverings
Slate is not the shallowest covering, and it is not the steepest. Marley prints a lowest pitch against each of its products, and the spread is wide. These are Marley product names, not regions:
| Product | Minimum pitch |
|---|---|
| Canterbury clay tile | 40 degrees |
| Plain concrete tile | 35 degrees |
| Double Roman concrete tile (smooth) | 22.5 degrees |
| Lincoln clay pantile | 15 degrees |
| Mendip 12.5 concrete tile | 12.5 degrees |
Each tile has its own figure, so the table is no substitute for the data sheet of the product that is chosen. For stone tiles from Herefordshire quarries, ask the quarry what pitch it stands behind, since none of the figures above belongs to stone.
If a roof is too shallow for slate, the options come down to three: another covering, a membrane system for a flat or near-flat roof, or raising the pitch with new timbers, which is a structural job needing its own design and a check with building control. The comparison of products lives in our guide to roof pitch limits for tiles and slates.
Low-pitch slating and the two countries' rules
Cupa's pitch guidance is a manufacturer's, so it travels across the border unchanged. The paperwork around a change of covering or a new roof is another matter.
- England: the Planning Portal's re-roofing guidance says a covering 15 per cent heavier or more needs Building Regulations approval, and a re-roof that affects less than 25 per cent of the building envelope and less than 50 per cent of the roof normally does not need an application.
- Wales: for re-roofing the Welsh Government expects Building Regulations approval in most situations, so raise it with the council's building control team before work starts, whatever the pitch.
If your roof is close to the limit, a short list will help the conversation with a roofer:
- Ask for the measured pitch of every slope, and not an estimate made from the road.
- Ask which slate is proposed, and its length and overlap.
- Ask whether the site counts as moderate exposure, and who decides.
- Ask for the supplier's data sheet in writing.
We answer those four on every slate quote, and the written total names the slate. The wider subject lives under slate roofing.