01432 610152 Get a quote Call 01432 610152

Roofers in Westfields

Chimney, slope and roof window work in Westfields, on the north-west side of Hereford.

Westfields lies 1.5 road miles out, north-west of the city centre. We start at the stack, photograph the lead and give one written price.

Get a free quoteCall 01432 610152

What goes wrong high up in Westfields

  • Older cottages with weathered clay tile roofs and brick chimneys behind a flint wall
    Stacks and their leadLead around a chimney can split, and the damp then reaches a ceiling.
  • Slate roofs and chimney stacks along a red brick Victorian terrace
    Underlay and battens below the tilesA split membrane or a rotted batten shows only once tiles are lifted.
  • Newer homes with grey concrete tile roofs along a curving estate road
    Roof windows in loft roomsA new window must meet the Part L figure with sound flashing.

Mapping Westfields

Westfields on a street map, with a dashed circle around the town and the nearest towns we cover. Tiles © Esri; map data © Esri, HERE, Garmin, OpenStreetMap contributors.

Stack, slope and window in Westfields

Westfields from the top of the stack to the roof window, in survey order

We open on the chimney stack and the lead around it, work down the slope to the underlay and battens, and finish at the roof window, where Part L sets the figures and the Huntington conservation area boundary gets a look on the council's map.

A drawn cut-away section through a Herefordshire border house: the front of the main roof is cut open to show the rafters, underlay, battens and slates, beside a black-and-white timber-framed gable. Numbered, from the ridge down: 1 Chimney lead; 2 Slope and underlay; 3 Roof window.

Fig. 1 House in section, with the three Westfields callouts numbered along the survey.

Callout 1 of 3

Stack, lead and chimney breast on a Westfields roof

The stack is the tallest thing on the roof, so the survey begins there. From the ladder we look at four things: the pots, the flaunching (a mortar fillet seating the pots and shedding water off them), the pointing on each face, and the lead flashings where the stack meets the slope. Pointing is the mortar between the courses of brick or stone. Where it has eroded, the open joints let moisture work into the masonry, and we photograph every face so that you can see the state of each one.

Three pieces of lead do the work round a stack: the flashings, chased into the masonry courses and laid down upon the tiles; the soakers, interleaved with the tiles up each side; and the back gutter, a trough above the stack that steers runoff to both sides. Royston Lead's table lists Code 4 for pitched valley gutters, flashings and soakers, while Code 5 and Code 6 suit flashings, valley gutters and dormers too. Which code goes where depends on the position on the stack. Lead expands and contracts, so a flashing fixed too stiffly will split along its fold and let the damp through.

Taking a stack down is more than roof work. According to the Planning Portal, building regulations approval applies without exception when a chimney breast is removed; the breast is structural. Should a Westfields breast be part of a party wall with next door, the Party Wall etc. Act 1996 comes in: the building owner serves the notice, which sets a wait of at least two months until removal, and a surveyor is called in only when next door disagrees or does not answer within 14 days. Questions about a party wall go to a party wall surveyor, not to building control.

Reaching a stack from the street may mean scaffold on the footway, and then section 169 of the Highways Act 1980 requires a licence. We arrange the licence with our scaffolder and fold the scaffold into the one written total price. Our chimney repairs page covers repointing, rebuilding and the lead in more detail.

What sits on a Westfields stack

Pots
Seated firmly and checked for cracks
Flaunching
Sloped mortar collar, re-formed where it has cracked
Flashings
Lead tucked into joints and dressed over the tiles
Soakers
Small lead sheets under each course beside the stack
Back gutter
Lead tray behind the stack that turns water round it

Lead has to be free to move, or it splits along the fold and the ceiling pays.

Fig. 2 Chimneys, drawn close

Callout 2 of 3

Underlay, battens and ventilation under a Westfields slope

Below the stack, the slope is where a repair and a re-cover part company. A single slipped tile is a patch. A slope whose battens have rotted or whose underlay has split is another question, because the covering has to come off to reach them. Underlay is the sheet membrane that goes over the rafters and under the battens. It catches what blows under the tiles and carries it to the gutter. We lift a few tiles, photograph the underlay and the battens, and show you what lies behind them before anyone proposes a strip.

Underlay comes in two families, and they ventilate differently. In Marley's guidance, an HR (high-resistance) underlay counts as not vapour-permeable, and for that reason a cold roof beneath it must be ventilated at the eaves, by a 25mm gap on pitches of 15 degrees or less and a 10mm gap on steeper ones. Where an air-permeable underlay sits above a well-sealed ceiling, the gap that ordinary eaves construction leaves can be relied on, but only where the product certification conditions are met. Which one is in your loft decides what a new covering needs, and BS 5250 is the code for controlling condensation in buildings.

Weight matters when the covering changes. In England the Planning Portal sets its limit at a new covering that makes the roof covering weigh 15 per cent or more than before, and that is a Building Regulations matter, not a planning one, with the rafters checked first. Swapping like for like is simpler. The Portal's re-roof test for England sets its limits at less than 25 per cent of the building envelope and less than 50 per cent of the roof.

Not every slope needs the full treatment, and a patch on a sound slope is not a reason to strip the whole of it. Where the battens are sound and only a handful of tiles have slipped, we reset those and leave the rest, and the written quote names each slope that is touched. Our pitched roofing page covers re-tiling, underlay and battens for slopes that must be stripped completely.

Looked at under a Westfields slope

  • Underlay for splits, tears and sagging
  • Battens for rot at the nail points
  • Eaves openings for the ventilation gap
  • Tiles for cracks, slips and loose nibs
  • Insulation placed so air can still move
Fig. 3 The slopes, drawn close

Callout 3 of 3

Roof windows, the Huntington conservation area and Moor Farmhouse

The last callout is the roof window. A roof window means a glazed unit fitted within the plane of the slope, while a rooflight is the kind that sits proud of a flat roof or rises as a dome. They carry different Part L figures. Under AD L 2021, Table 4.2 allows a roof window 1.4, or a Band B window energy rating, and a rooflight 2.2. The same values reappear in Table 3.2 when AD L 2026 takes effect on 24 March 2027. We fit to the figure in force on the date of the work, and the product label shows it.

Planning is a separate question. Huntington, a conservation area designated in 1975 according to Herefordshire Council's list, lies close to Westfields. Whether your street falls inside it is for the council's map to show, and whether an Article 4 direction applies is for Herefordshire Council to confirm. Dormers and roof windows each bring planning matters, and our planning guide for roof windows lays out the conditions in full.

Near the middle of Westfields, Historic England's list records Moor Farmhouse, Grade II (list entry 1196852, first listed 10 June 1952). Section 7 of the Planning (Listed Buildings and Conservation Areas) Act 1990 means that any work affecting a listed building's character needs listed building consent, whatever the planning position. For a listed roof we agree the covering, the lead and any new opening with Herefordshire Council before a single item is ordered.

Fitting a roof window means trimming the rafters, framing the opening, flashing it into the covering and lining the reveal inside. The flashing kit is chosen to suit a tile or a slate covering, so that it lies flat to the slope and drains into the gutter below, and the lining is finished and painted to match the ceiling it joins. Westfields addresses can use Herefordshire Council Building Control at Plough Lane, Hereford (01432 261938), or a registered building control approver. Our skylights page covers the glazing, the flashing kits and the finish.

Terms found on a roof window quotation

Roof window
A glazed opening set in the plane of a pitched slope
Rooflight
A glazed unit that sits proud of a flat roof
WER Band B
An energy rating route to meet the window figure
U-value
How much heat passes through a part of the building

Stacks, underlay and roof windows in Westfields

Why does lead split around a Westfields chimney stack?

Lead expands and contracts as it warms and cools, so a flashing fixed too stiffly across the stack can tear along its fold. A lifted edge or a hairline split lets damp in behind the chimney, where it may appear first as a ceiling stain or a damp patch in the loft. We dress new lead so that it can move, choose the code from Royston Lead's table to suit the job, and replace split sheets rather than coating them with sealant.

Can the chimney breast in a Westfields house come out with the stack?

The Planning Portal says that building regulations approval always applies once a chimney breast comes out, because the breast is structural. If it is built into a party wall, the Party Wall etc. Act 1996 applies as well, and the Westfields neighbour's notice period is at least two months, counted from service to the first cut. We do the roof side, and Herefordshire Council Building Control or a registered building control approver approves the structural work.

Does the Huntington conservation area reach as far as Westfields?

Herefordshire Council's list gives 1975 as the designation date for Huntington, and that conservation area is the one nearest Westfields. Your own street may or may not fall inside it, so check the council's map. Ask Herefordshire Council about any Article 4 direction, and have our planning guide to hand before you settle on a roof window or dormer. The county has 64 conservation areas in all.

What does scaffold on a Westfields footway involve?

Section 169 of the Highways Act 1980 makes a licence compulsory for any scaffold obstructing the highway. Herefordshire Council's charge is £167, and the licence it buys lasts a maximum of one month; to extend, it is £123 per month, and the council needs the application lodged no later than 10 days before the poles are put up. We arrange the licence with our scaffolder, the written total price includes the scaffold, and a busier main road by Westfields work is put to the council first.

What U-value must a roof window in a Westfields loft room meet?

In England, AD L 2021 Table 4.2 gives 2.2 for a rooflight and holds a roof window to 1.4 or the window energy rating route. AD L 2026 carries the same values in Table 3.2 from 24 March 2027. The roof insulation of a loft conversion falls under Table 4.3, where the renovation figures run from a 0.35 threshold to an improved 0.16, which is a different number from a window's.

Is consent needed for repairs to a listed house like Moor Farmhouse?

Moor Farmhouse is listed Grade II (list entry 1196852, first listed 10 June 1952). Under section 7 of the Planning (Listed Buildings and Conservation Areas) Act 1990, works that would affect a listed building's character need listed building consent, and a listed house's permitted development rights stay in place alongside it. Ask Herefordshire Council before any change to the covering, the lead or the chimney, and we will attach the survey photographs.

Book a stack-to-window survey in Westfields

Describe the fault on the roof or the ceiling, attach a picture, and we will agree a day for the survey.

10-year workmanship guarantee, in writing