Callout 1 of 3
Roof windows and the figures behind them
A roof window is a gap cut into the weatherproofing, so a Sheet survey looks at it early. We check the glass for failed seals and misting, the frame for stains and softness, and the flashing around it, which is the set of pieces that carries water past the frame and down the slope. A window that was well fitted still leaks if the covering beside it has slipped, so the courses on both sides and the ones above are read as well. From the loft we examine the lining and the timbers round the opening for damp. The frame is set to the slope at the depth the maker specifies, and the flashing kit is dressed over the covering so water passes down the sides and over the head, not under them. A new opening also means cutting a rafter, so the framing around it is trimmed with timber of a matching size, and a photograph is taken of that stage before the lining hides it.
England sets thermal figures for new openings. AD L 2021 Table 4.2 gives a window, roof windows included, 1.4 or WER Band B, and gives a rooflight 2.2 W/(m²·K). Rooflights take the 2.2 figure; a roof window takes the window one. Regulation 2 of the 2010 Regulations keeps roof windows and roof-lights outside the thermal element, along with windows and doors, which is why the glazing is judged on its own figures and the roof around it on Table 4.3. AD L 2026 renumbers these as Tables 3.2 and 3.3 from 24 March 2027.
A loft room adds fire questions. AD B says escape windows apply to storeys within 4.5 m of the ground, with an openable area of 0.33m2 or more, 450mm high and 450mm wide at the least, and a bottom edge no higher than 1100mm above the floor. Planning permission for a new window or a dormer is a different question, and our planning guide for roof windows sets out where the limits fall. For work on the glazing and its surround, our Velux and skylight installation page explains how a window is fitted into an existing slope without disturbing more covering than it must.
Window or rooflight?
Do roof windows and rooflights meet the same U-value?
No. AD L 2021 Table 4.2 sets a window, roof windows included, at 1.4 or WER Band B, and the figure for a rooflight is 2.2. The two sit on separate rows of the table, so each is checked against its own figure.
A window that was fitted well still leaks when the slates beside it have slipped.