In brief
Yes, where it passes the size tests. Both Approved Documents call for an openable area of 0.33 m² or more, 450 mm high and 450 mm wide at the least, with the lowest edge of that opening at or below 1100 mm from the floor. In England that is paragraph 2.10, which covers storeys within 4.5 m of the ground. In Wales it is paragraph 3.8. Building control confirms your window.
The size tests a roof window has to pass
The tests measure the opening, not the frame, and they match on both sides of the border:
- an openable area of at least 0.33 m²
- an openable area at least 450 mm high and 450 mm wide
- the lowest edge of the openable area at most 1100 mm above the floor
In England, Approved Document B (the 2019 edition incorporating 2020, 2022, 2025 and 2026 amendments) puts these in paragraph 2.10. In Wales, Approved Document B volume 1 (the 2006 edition incorporating 2010, 2016 and 2020 amendments) puts them in paragraph 3.8, where the openable area is described as unobstructed.
The openable area is smaller than the glass. The data sheet for the window gives the clear opening once the sash has swung or pivoted, and that is the figure to test. A roof window set high in the slope can sit too far above the floor, so the position of the lower edge counts as much as the size, and a sill that passes on paper may still be awkward to climb through. Our page on how big an escape roof window must be goes through the dimensions.
Which storeys a window can serve
An escape window serves a storey close enough to the ground that someone can leave by it and be reached. In England, paragraph 2.10 is written for storeys not more than 4.5 m above ground, so it does not apply above that height. Paragraph 2.5 deals with those storeys, calling for a protected stairway or an alternative escape route.
In Wales, paragraph 3.6 gives the options for the top floor: protect the stair, or divide the top storey off and give it a way out of its own. Paragraph 3.8 sets the size of the escape window where a window is the answer. The 4.5 m height is English wording and is not applied here to Wales.
Roof windows can go into a loft room, which is the top storey of the house. Whether that room relies on a window, a stair or a separate route is a question of fire design, settled with building control before the roof is opened. Our page on re-roofing with a loft conversion and the escape rules sets out the routes.
Energy figures and planning for the window itself
An escape window still has to meet the other rules for a roof window. In both England and Wales, a rooflight takes 2.2 W/m²K and a roof window takes 1.4 or WER Band B. Our page on roof windows as escape windows covers the product side.
Planning differs by side of the border, and it is a separate test from the fire rules above:
| Place | Position |
|---|---|
| England, house | Normally permitted development under Class C, with conditions |
| England, conservation area | Class C is not removed, but check for an Article 4 direction |
| Wales, article 1(5) land | No permitted development for a roof light, so planning permission is needed |
For a new rooflight in Wales, the Welsh Government adds that Building Regulations approval will generally be needed too. A window can pass the fire tests and still fail on planning, or the other way round, so both are settled before the order goes in. The conditions are in our guide to roof window planning in England and Wales.
What we check on the survey
We measure the opening that exists, or the one proposed, and set the clear opening from the maker's data against the three tests above. Where the window is to be a swap for an old one, the old opening is measured first, since a replacement of the same size inherits the same limits. We also look at the floor space beneath the window, because a sloping ceiling, a piece of furniture or a stair opening can make a compliant window hard to reach. We note how high the lower edge of the openable area will sit above the floor of the room, photograph the slope and the inside of the room, and show you.
If the numbers do not work, you hear before anything is ordered. Sometimes the answer is a different window, or one set lower in the slope, and sometimes the escape has to be something else. A particular window cannot be promised to satisfy an approved document, because building control decides that for your room.
After the survey you receive one written price that names the window, the flashing and any structural opening. For the wider choices, see Velux and skylights.