A roof window keeps water out through the flashing around it. Flashing is the trim that closes the gap between the frame and the roof covering, and it has to carry rain off the frame, across the courses of tiles or slate, and down towards the gutter. Window makers supply it as a kit, sized to the window and shaped to a type of covering. A kit chosen for the wrong covering leaves a gap that no sealant will hold for long.
Tiles and slate behave differently here. Tiles come in profiles that rise and fall, or lie flat in plain courses. Slate lies in thin overlapping rows with a head lap. On the older stone-tiled roofs of Herefordshire and the Welsh border, the pieces vary in thickness from one to the next, and a factory kit may not fit at all. The covering decides what goes round the window, and a mismatch builds a weak point into the roof from the first day.
The sections below cover how a kit is chosen, what slate needs, when lead is the better route, the fixings, the rules in England and Wales, and what sets the price. For the whole range of window work, start at our Velux and skylight page.
What a kit is, and why the covering decides it
Each kit is a bundle of pre-formed pieces made for one window size and one type of covering. A bottom piece laps over the tiles or slates below the frame, side pieces step through the courses beside it, and a top piece turns water round the head. Between them they pass rain off the frame and onto the covering, so the kit and the roof must be matched.
Coverings fall into two groups for this purpose. Profiled tiles rise and fall across each tile, so the kit has to follow that shape and close the gaps beneath it. Flat coverings, such as slate and plain tiles, lie in overlapping courses, so their kits sit close to the courses with slimmer edge pieces.
| Covering | Kit style | Check before ordering |
|---|---|---|
| Profiled concrete or clay tiles | Follows the profile | Tile range and profile depth |
| Plain tiles and slate | Sits within the courses | Covering thickness and lap |
| Stone tilestones | Lead worked by hand | Thickness and size, piece by piece |
Tile ranges differ widely. Marley's minimum-pitch table runs by product name, with the Mendip 12.5 concrete tile at 12.5° and the Canterbury clay tile at 40°; the table itself tells readers to consult each product's data sheet. The maker's sheet for the window says which kit goes with which covering and how deep that covering can be. That sheet decides the order, not the picture on the box.
Slate: lap, pitch and the cut at each side
Slate is laid in overlapping courses, and the head lap, the distance each slate reaches over the one two courses below, is what keeps water out. Cupa, the slate supplier, says BS 5534:2014+A2:2018 "also indicates that the minimum roof pitch for natural slate is 20 degrees in the case of a project situated in an area with moderate exposure and with a slate 500mm long and a 115mm overlap". It also says "hook fixings should not be used on any pitch below 25º".
Those conditions matter once a window goes in. Cutting an opening means cutting courses at both sides, and every slate trimmed to the opening needs its own fixing. On a shallow roof a hook is not an option, so a nailed or clipped fix is needed. A kit for slate has to sit within the laps, so thick or uneven reclaimed slates are checked against the kit's maximum covering depth before the order goes in.
Before we cut a slate roof, we check:
- the length of the slate and the lap, since both change what the kit can cover
- how brittle the courses beside the opening are, because ageing slates can crack when lifted
- the batten gauge, so the cut courses land on a batten
- the fixings already in the courses, nail or hook, and the pitch
- the underlay below, and whether it is torn or sound
Our guide on whether a Velux can go in a slate roof goes through the window side of the same question.
Stone tilestones and old roofs: when lead takes over
Stone roofs in the old parts of Herefordshire are laid with sandstone tilestones from local quarries, and the Herefordshire building stone atlas credits the St Maughans sandstones around the Golden Valley as the principal source. It adds that Longtown's older cottages still wear flagstones, and in Kington the older cottages carry flagstones from the Raglan Mudstone. SPAB's technical note calls Welsh slate and stone roofs "predominantly double-lapped", which means each piece covers parts of two courses. Stone tiles are judged on the roof itself, piece by piece.
A factory kit assumes regular courses of a known thickness. Tilestones vary in thickness, size and lay, so the flashing for a window set in stone tilestones tends to be worked by hand in lead, cut to the courses on the day. The sheet is chosen by what it must do:
| Code | Thickness | Colour | Used for |
|---|---|---|---|
| 3 | 1.32 mm | Green | Recommended for lead soakers only |
| 4 | 1.80 mm | Blue | Soakers, flashings, valleys, dormers |
| 5 | 2.24 mm | Red | Flashings, valleys, parapets, dormers |
Soakers are folded lead pieces laid one to each course at the side of the opening, turning up against the frame. For correctly installed lead flashing, MyJobQuote's line is that it "can last for over 80 years", a hedge and not a promise. Lead worked to a stone roof also keeps the look of the house, which counts if the house is listed, or stands in a conservation area.
Fixing the covering round the opening
Flashing keeps water out of the gap, and the fixings keep the covering in place round it. Marley notes that "Installing to BS 5534 isn't required by law", but that the 2015 amendments made it clear mortar "could no longer be relied upon as the only means of securing the roof covering". Mortar is not banned. It is simply not the only fix. BS 8612 covers dry-fix, meaning ridge, hip and verge systems held mechanically without mortar.
That has a practical edge at a window. Tiles cut to fit beside the frame have free ends, and each one needs a mechanical fixing of its own, not mortar or sealant alone. Sealant has a place as a finish and a secondary seal. It does not replace a lapped flashing, because it hardens and cracks over time, and once it opens there is nothing behind it.
A flashing job done carefully leaves:
- every cut tile or slate fixed, and the cuts clean rather than chipped
- the bottom piece lapping over the covering below the frame, and the side pieces stepping through the courses beside it
- the top piece turning water round the head and onto the courses on either side
- no sealant standing in for a lap that should be metal
On a re-roof, we fit the window flashings as the new covering goes on, because that is the only moment when the laps can be built in from the start. On an existing roof, a replacement kit goes in alongside the covering that is already there, so the survey examines the courses beside the opening.
What the rules say in England and Wales
A flashing job on its own is a repair, but the window it serves comes with rules, and they differ across the border.
- In England, Table 4.2 of Approved Document L 2021 gives a new window in an existing home 1.4, or WER Band B, with roof windows included. In Wales, Table 4.1 of the Welsh Approved Document L gives "Window or roof window" the same 1.4 or minimum WER Band B. Rooflights have their own 2.2 in both.
- In England, Class C of the 2015 General Permitted Development Order does not cover an alteration that would protrude more than 0.15 metres beyond the plane of the slope of the original roof. A frame and kit sit above the covering, so the height is worth checking on the maker's sheet.
- In Wales, Class C of the 1995 Order sets the same limit as 15 centimetres, and condition C.2(a) says the materials must "so far as practicable match" the existing. Welsh Class C also withholds roof lights on land in a conservation area, a National Park or a National Landscape, so a planning application is needed.
- In Wales, the Welsh Government says approval under the Building Regulations will generally be needed for installing a new rooflight.
Listed houses keep Class C but need listed building consent too: the Historic Environment (Wales) Act 2023 governs in Wales, and the Planning (Listed Buildings and Conservation Areas) Act 1990 in England. Our England and Wales planning guide sets out each condition in full. England's next edition of Approved Document L takes effect on 24 March 2027, and the new Welsh edition on 4 March 2027. For the energy side in detail, see roof window energy rules.
What sets the price of a flashing job
The price follows the roof, not the window. Four things decide it: the size of the window, the covering and whether a manufactured kit will fit, how much lead has to be worked by hand, and the access, including whether a scaffold is needed. We survey first, photograph the existing flashing and the courses beside it, and give one written total price afterwards.
Published ranges show how wide the spread is. MyJobQuote's chimney leadwork page (22 September 2026) gives around £200 for a chimney flashing patch, around £570 for a full replacement, and £350 to £920 for full chimney leadwork, "depending largely on whether scaffolding is required". Checkatrade (June 2026, ex VAT) gives lead flashing repairs at £50 to £70 per metre. Those are per-metre and per-job figures from different pages, and they do not combine into a total for any roof.
On the window itself, MyJobQuote says a Velux costs around £100 less where it is a plain swap into an opening that is already there, and lists a small FK04 centre pivot at around £330 as a product price. Checkatrade gives rooflight replacement as "from £1,000", a starting figure and not a quote. When the flashing is the only thing that has failed, the honest answer can be a flashing repair and not a new window, and we say which one the photographs support.
Any scaffold is part of that written total, and the site is left tidy.