01432 610152 Get a quote Call 01432 610152

Escape window size

How big must an escape roof window be?

The clear opening, not the frame, is measured: at least 0.33 m², with 450 mm as the minimum each way, and a lower edge no higher than 1100 mm.

In brief

The clear opening must have an area of at least 0.33 m², measure at least 450 mm high and 450 mm wide, and have its lower edge no more than 1100 mm up from floor level. The English source is Approved Document B, paragraph 2.10, and it serves storeys within 4.5 m of the ground. The Welsh source is Approved Document B volume 1, paragraph 3.8. Building control decides for your room.

The three measurements

All three tests apply to the gap you can climb through once the sash has moved, not to the glass or the frame:

  • an openable area of at least 0.33 m²
  • a height of at least 450 mm and a width of at least 450 mm
  • a lower edge of the opening that sits 1100 mm or less above the floor

The first two work together. An opening 450 mm by 450 mm measures about 0.2 m², which falls short of 0.33 m². To reach the area, one side has to be longer, for example 450 mm by about 735 mm. A window can pass the minimum on each side and still fail on area.

The wording differs a little between the two documents. England's paragraph 2.10 asks for "a minimum area of 0.33m2". Wales's paragraph 3.8 asks for "an unobstructed openable area" of that size, so a sash that leaves a bar across the gap is judged by what is clear, not by what is glazed. Both measure the opening in the position the sash is held when it is open.

Why the 1100 mm test is awkward in a slope

On a wall, the sill height above the floor is easy to read off. In a roof slope the window lies at an angle, and the floor sits well below its upper edge. The limit of 1100 mm is taken to the lower edge of the clear opening, so that is the line that counts.

This is why an escape window may need to go lower in the slope than it would for a view. A window set high to clear a bed or a desk can fail the height test even though its size is right, and a taller unit may be needed so the area still reaches 0.33 m² from a lower starting point.

We measure from the finished floor of the room, which can be higher than the joists if a new floor is going down. We also note the pitch of the roof, because the way the sash swings changes how much clear gap you get from the same frame.

The data sheet for the window gives the clear opening to set against these tests, and building control can ask to see it.

Which storeys the window rule serves

The size tests matter only where a window is the way out. They do not turn every roof window into an escape window:

Where each approved document puts the window rule
CountryDocumentWhat it covers
EnglandAD B, para 2.10Windows for storeys within 4.5 m of the ground
EnglandAD B, para 2.5Above that height, a protected stairway or an alternative escape route
WalesAD B vol 1, para 3.8The size of an escape window
WalesAD B vol 1, para 3.6A stair that is fire-separated, or a divided top floor with an exit of its own

The 4.5 m test is English wording, and we leave it out for a Welsh address. Our page on whether a roof window can be an escape window covers when a window forms part of the escape route at all. For a loft room that is the top storey, the stair and the doors are looked at as well, since a window is one answer among several, and the choice is made with building control before the roof is opened.

What we check before ordering

When we survey, the first job is the opening itself, whether it already exists or is proposed. The clear opening on the maker's data goes against the three tests, with the height of the lower edge above the floor noted beside it. We photograph the slope and the room so that you can see the same things.

If the figures fall short, you hear it before any order goes in. A different size, a lower position in the slope or a second window may fix it, or the answer may lie in the stair and the doors instead.

The English document is the 2019 edition incorporating 2020, 2022, 2025 and 2026 amendments. The Welsh one is the 2006 edition incorporating 2010, 2016 and 2020 amendments. Your price is written down as a single total that names the window you choose. The size of the opening is worked out first, since the window follows from it. If a larger unit is needed, the extra framing in the rafters is inside the same total. More on the product side is in roof windows as escape windows, and the full range sits under Velux and skylights.

Related questions

Can the same window meet the size test and give a view?

Sometimes, if it is large enough and its lower edge sits low in the slope. A tall window set high may fail the 1100 mm test. We measure the clear opening and the height above the floor before ordering, and building control decides whether it counts for your room.

Does a fixed roof window count as an escape window?

No. Both approved documents test an openable area, so the sash has to open and leave a clear gap of at least 0.33 m². Paragraph 2.10 applies in England and paragraph 3.8 in Wales. A fixed light adds daylight but cannot be the way out of the room.

Get your free roof quote

Tell us about the roof and we will arrange a survey.

10-year workmanship guarantee, in writing