01432 610152 Get a quote Call 01432 610152

Wall junctions

Leaks where a roof meets a wall: abutments, soakers and flashings

Where a roof slope butts against a wall, the seal is a strip of lead. This guide shows how that junction fails, how to read the stain it leaves and what the repair involves.

Horizon Roofing Hereford 9 min read

Extensions, porches, lean-to sheds and garages share a feature: a roof that stops against a wall taller than itself. The meeting line is called an abutment. Rain lands on the slope, but rain also runs down the wall face and arrives at the same line, so the seal has to cope with two sources of water at once.

That seal is nearly always lead, shaped by hand to the covering and fixed into the wall. When one edge lifts or splits, a trickle gets behind it. The mark inside appears later and lower down, in a corner or along the edge of a ceiling, sometimes well away from the real gap, which is why these leaks are so easy to chase in the wrong place.

Below, the junction is named part by part, the stain is read for clues, the failures are listed and the repair is set out from smallest to largest, with the cost figures that others publish. A short section covers a neighbour's wall, and which approval rules govern a repair that widens, whichever side of the Welsh border you live. The wider repairs range is on our roof repairs page.

Side and head: the two kinds of wall junction

A flashing is a strip of metal that bridges the joint between the covering and something rising out of it. Two junctions with a wall are common, and one roof can have both.

The two wall junctions
JunctionWhere it isHow it is sealed
Side abutmentThe slope climbs beside a wall that stands above itSoakers under the covering, step flashings over them
Head abutmentThe top edge of a lean-to finishes against a wallAn apron or cover flashing along the wall

A soaker is an L-shaped piece of lead, one for every course of slates or plain tiles. Its short arm turns up the wall and its long arm slides under the covering. The step flashing over the soakers is cut into a staircase to follow the courses. Its upper edge goes into a raglet, a slot chased along a mortar course of the wall and pointed once the lead is set.

Both junctions depend on one idea: each layer overlaps the one beneath it, so water is handed downhill and outwards. A fault anywhere in that sequence breaks the chain, and the stain follows. At the head of a lean-to there is no slope to follow, so one long strip does the job of the steps. It is tucked into a raglet at the top and dressed down over the first course of the covering.

Reading the stain: roof, wall or something else

A mark beside a wall has several possible sources, and the pattern narrows them down.

What the mark may be telling you
What you noticeWhat it may point to
A ceiling stain along the wall line after rain on that sideA gap in a flashing or a slipped soaker
Damp on the wall face below the junctionWater behind the lead, or a fault in the wall above
Damp below a gutter or downpipe on the same wallA leaking joint or an overflowing outlet
A patch that comes and goes with no link to rainCondensation, not a leak

In the loft, a torch along the rafters beside the wall shows tide marks, damp felt and rust on nails. The leak sits uphill of the stain, so we follow the marks upwards and photograph each one. Outside, the check runs along the whole line from the lowest course to the top. It helps to note which wall and which room the mark is in, and how long after the rain it showed, because those notes shorten the survey and point us to the right junction first.

Timing helps. A stain that shows only after wind-driven rain on one side suggests a gap that opens when water is pushed sideways, and our guide to roof leaks that appear only in wind explains that pattern. A mark with no link to rain may be moisture from the house, which our guide to condensation or roof leak sorts out.

How these joints let rain in

The lead itself need not be the part that fails. Its fixing, the wall behind it or the covering beside it can give way instead. From the garden with binoculars, or from the loft, the signs include:

  • a strip of flashing that has lifted away and stands proud of the wall
  • lead that has split open at a fold, for example at a corner or where one piece laps another
  • pointing missing from the raglet, leaving the top edge unsupported
  • a mortar fillet or a line of sealant that has cracked and left the wall
  • a soaker that has slipped, or a slate or tile beside the wall that has moved
  • moss, leaves and grit packed into the angle where roof and wall meet

A fillet is a bevelled strip of mortar run along the junction. It is a stop-gap rather than a flashing, because roof and wall move at different rates and the mortar cracks when they do. A bead of sealant laid over a failing joint can look like a cure for one winter while water still passes behind it, and it makes the next inspection harder.

Water can also reach the same spot through the wall itself. Cracked render, open joints and a downpipe discharging against the wall face all deliver damp to the room beside the junction. A fault of that kind is cured at the wall, so the lead is not renewed until the survey shows the lead is the cause. Where it is not, the finding is explained and the wall repair that is needed is pointed out, and a mason or a builder may be the right person to carry it out.

The repair, from small to large

The repair follows the fault. In rising order of work:

  1. Re-dress and re-fix lifted lead, so it lies flat against the wall and the covering again.
  2. Rake out the raglet and repoint it, to hold the top edge of the lead.
  3. Cut out a split piece and let in new lead of the right code.
  4. Renew the soakers, which means lifting the slates or tiles beside the wall course by course and laying them back over new lead.
  5. Rebuild the whole abutment where lead, pointing and covering have all failed.

Sealant over a gap is left off that list, because it masks the fault and does not cure it.

On the lead itself, Royston Lead's brochure marks Code 3 (1.32 mm) as "Recommended for lead soakers only", and lists flashings under Codes 4, 5 and 6. The code goes on the written price so that you can check it. Whichever step applies, the waste goes with us when we leave. MyJobQuote says correctly installed lead flashing "can last for over 80 years", a hedged claim about good work.

Published costs give a sense of scale. Checkatrade's June 2026 rates (ex VAT) for lead flashing repairs are £50 to £70 per metre, a rate and not a total. MyJobQuote, writing about chimney leadwork on a page updated 22 September 2026, puts a patch repair around £200 and a full replacement around £570, and gives £350 to £920 for full leadwork, linking the spread to whether scaffolding is needed. You get photographs of the junction before and after, and the price as a single written total.

Different coverings and walls need different details

The lead is shaped to what it meets, so the covering and the wall both change the work.

  • Slates and plain tiles take a soaker under every course, as described above.
  • Large profiled tiles cannot be lifted course by course in the same way, so the lead can be a continuous strip dressed to the shape of the tile.
  • Stone tilestones are heavy, and Stone tilestones are heavy, and in SPAB's words Welsh slate and stone roofs "are predominantly double-lapped", so the courses overlap and the soakers are cut to suit what is on the roof.

On a brick wall the raglet follows a mortar joint, and a clean line is easy to cut. On a stone wall it follows the bed of the stone, which can run uneven. On a rendered wall, the top edge has to be fixed in or behind the render, and cracked render above the lead is itself a way in for water. Where hung tiles or boarding cover the wall above the roof, the lead has to sit behind the cladding and not in front of it.

Older houses can have walls that have been repaired in several different mortars over the years. A hard cement pointing can damage soft stone around a raglet, so the mortar is chosen to match what is already in the wall. The mortar for any repointing is matched to the existing wall in colour and hardness, so the repair does not stand out from the street. Access is part of the plan too: a junction over a conservatory or a bay window can call for a tower or a scaffold, and our guide to ladders, towers or scaffold sets out the choice.

A shared wall, and the rules if the repair widens

On a terrace or semi, the wall a roof runs into may be shared with a neighbour. The Party Wall etc. Act 1996 applies in England and in Wales. Section 2(2)(j) lets a building owner cut into the wall of next door's building to fit a flashing. The notice has to come from the person whose building work it is, and section 3(2)(a) sets two months as the minimum lead time. Written consent under section 3(3)(a) lets the work proceed, and 14 days of silence counts as dissent under section 5. Only then does a surveyor come in under section 10. Questions about the Act go to a party wall surveyor, not to building control.

If the repair grows into re-covering the roof beside the wall:

  • In England, the Planning Portal says no Building Regulations application is normally needed where "Less than 25 per cent of the total 'building envelope'" and "Less than 50 per cent of the roof" is affected. A new covering that adds "15 per cent or more" in weight also calls for approval.
  • In Wales, the Welsh Government says of re-roofing: "In most situations, this work will need Building Regulations approval."

A listed house adds a step of its own. In England the consent rests on section 7 of the 1990 Act. In Wales it rests on sections 88 and 89 of the Historic Environment (Wales) Act 2023, in force from 4 November 2024. For a conservation area or an Article 4 direction, check with your council. Herefordshire Council says the county has 64 conservation areas.

Wall junctions: your questions

Can the joint between roof and wall be sealed with mastic?

A bead of sealant can hide a gap for a season, but it does not rebuild the junction. Roof and wall move at different rates, and sealant tears away from the masonry. The lasting repair is lead, held in a repointed raglet, and you are shown photographs of the fault before work starts.

Why does the damp show up so far from the junction?

Water that gets past a flashing lands on the underlay or a timber and runs downhill before it drips. The stain can then sit some way from the gap. We follow marks in the loft uphill first, then check the matching junction from outside, so the repair goes where the fault is.

Do I need my neighbour's agreement to repair a flashing on a shared wall?

Only if the work cuts into their wall or otherwise falls under the Party Wall etc. Act 1996. Then the person whose building work it is serves the notice, with at least 2 months of lead time, and the neighbour can consent in writing. A party wall surveyor can advise on the details of your case.

Get your free roof quote

Tell us about the roof and we will arrange a survey.

10-year workmanship guarantee, in writing