01432 610152 Get a quote Call 01432 610152

Roof underlay

What does roof underlay do?

Underlay is the membrane that runs across the rafters under the battens and tiles. It is the roof's second layer, and its type decides how the loft must breathe.

In brief

Roof underlay is a membrane stretched across the rafters, below the battens and the tiles. It acts as a back-up to the covering, catching what a gust drives past the tiles and passing it down to the gutter. Its type also shapes the loft's ventilation. HR stands for high resistance: that kind of sheet does not pass vapour and needs ventilation at the eaves, while an air-permeable kind can get by with a smaller gap if the ceiling below is tightly sealed. Underlay is renewed when a slope is stripped.

The layer you cannot see from the street

A pitched roof has more than the tiles you see. Rafters carry battens, battens carry the covering, and between the rafters and the battens sits the underlay. A tile or slate is a good cover, but it is not a seal, and a hard gust can push rain or powder snow up the laps. The underlay catches that and carries it down to the gutter.

It also deals with the inside. Warm, damp air from kitchens and bathrooms drifts up into the loft, and the underlay together with the ventilation planned around it decides whether that moisture escapes or lingers on cold timber. A roof that stays damp rots slowly and quietly.

You will not notice a good underlay. You notice a failed one: a stain on a ceiling, damp rafters, or daylight through a tear when the loft is dark. In an older roof the first underlay may be a bitumen felt that has dried, split and lost its grip, while newer roofs have a plastic membrane that can also be torn by a falling tile or a careless boot. Either way the condition is checked from the loft side as part of the survey, with photographs.

HR and air-permeable: two kinds with different needs

The two main kinds behave differently, and the difference governs how a cold roof is ventilated. In a cold roof the insulation is laid at ceiling level, and the loft above it is left cold and open to air coming in at the eaves. Marley's figures apply to that arrangement.

Underlay type and eaves ventilation, as Marley sets it out
UnderlayVapourEaves ventilation
HR (high resistance)Not vapour-permeable25 mm along the eaves at 15 degrees or less; 10 mm above 15 degrees
Air-permeable (LR)Lets air through3 mm, which ordinary eaves construction supplies, provided the ceiling is tightly sealed and the product meets its certification terms

That is why "breathable" is a loose word. An HR underlay is not breathable in the vapour sense, whatever the sales literature calls it, so it relies on a gap at the eaves, and pushing insulation into that gap defeats the whole arrangement. Loft insulation laid right out over the wall plate is one way it happens. Our guide to pitched roof underlay and ventilation goes through both types, and HR or breathable underlay helps you pick.

When underlay is renewed

Underlay cannot be reached without lifting the covering above it, so it is renewed when a slope is stripped, not as a stand-alone job. A repair to a few tiles does not renew it. A full re-tile or re-slate does, and it is the moment to put right anything the loft showed.

The things we look for beneath the covering are these:

  • Tears, splits or brittle patches, for example at the eaves or around a chimney
  • Laps that have opened, or sections that have slipped from their battens
  • Staining or mould on the underside, which points to condensation or an old leak
  • Whether the eaves still have their ventilation gap, or insulation has been pushed into it
  • Rafters and batten ends, for rot where water has sat

New underlay goes down with fresh battens, and its type is matched to the ceiling, the insulation and the ventilation the roof has. The survey photographs set out what was found, and you decide with them in hand. Eaves ventilation in a cold roof covers the gap in detail.

Standards, and the two sets of rules

BS 5250 deals with moisture in buildings; BSI lists it as current and under review. Approved Document C refers to the 2002 edition for its condensation requirement, so the two documents do not always sit at the same date. Marley's ventilation figures are the practical ones for tile roofs, and we work from the underlay's own data sheet too.

New underlay normally arrives together with a new covering, so the regulations enter at that point.

  • In England, the Planning Portal asks whether less than 25 per cent of the total building envelope is affected and less than 50 per cent of the roof, and where both hold, the Portal says an application is not normally needed; Approved Document L Table 4.3 sets 0.35 as the threshold and 0.16 as the improved roof figure.
  • In Wales, gov.wales says that when a roof is re-covered its thermal insulation should be improved too, and Table 11.1 of the Welsh Approved Document L gives 0.16, no worse than 0.35 where that is not feasible.

Our written price covers the underlay, the scaffold and the clearance. Start from the pitched roofing page for the rest.

Related questions

Can I see the underlay from my loft?

Yes, where the loft has no boarding or lining under the tiles, the underside shows between the rafters. Torn, sagging or damp-stained underlay is worth a photograph. Show it at the survey, and we check the same spots from above when we lift the tiles on that slope.

Is HR underlay a poor choice?

Not by itself. HR means high resistance, so it is not vapour-permeable, and Marley sets out the eaves gap it needs at 25 mm for pitches of 15 degrees or less and 10 mm above that. Problems come when the gap is blocked, or the underlay is chosen without looking at the ceiling and insulation.

Get your free roof quote

Tell us about the roof and we will arrange a survey.

10-year workmanship guarantee, in writing