On a tiled roof, the tiles are the part you can see from the garden. The battens and the felt are what sits beneath them. The battens are slim timber strips nailed across the rafters, and each course of tiles hangs on one by a nib, the small lug on a tile's back that hooks over it. The felt lies over the rafters and under the battens, and its job is to catch what gets past the tiles.
You cannot judge either from the ground. They show their age in the loft, or when a section of covering is lifted, and the decision to renew them is bound up with the decision to strip and re-tile. Below are the signs, the choice of underlay, the ventilation it needs and the approval rules for England and for Wales. Our wider pitched roofing work covers the rest.
One note on the word. On a flat roof, felt means the bitumen waterproof layer. On a pitched roof it means the underlay, and that is how it is used here.
What battens and felt hold up and keep out
A pitched roof is built in layers. The rafters carry the load. The felt lies over them. The battens are fixed through the felt into the rafters, and the tiles hang on the battens. Take any layer away and the ones above lose their support.
| Layer | What it does | Where you can see it |
|---|---|---|
| Tiles | Shed the rain and form the first line of weather protection | From the garden |
| Battens | Carry the tiles at the right spacing | From the loft, or with tiles lifted |
| Felt | Catches what gets past the tiles and leads it to the gutter | From the loft, between the rafters |
| Rafters | Carry the whole assembly | From the loft |
Two features of the felt matter to a tiled roof. It must run down to the eaves and discharge into the gutter, or what it catches has nowhere to go. And it must be laid with the right slack between rafters, because the 2018 amendment to BS 5534 refers to a maximum drape of 15mm, according to Marley.
The battens have a quieter job. They set the gauge, which is the spacing of the tile courses, and they take the weight of the tiles and the pull of the wind on every one of them through the nails and clips. The felt can be the older bitumen type or a modern membrane, and either way it is hidden once the tiles are on.
Signs the battens or the felt have failed
Most of the evidence is in the loft. We go up torch in hand, keep to the joists and the boarded areas, and look at the underside of the roof from the hatch towards the eaves.
- Daylight showing between the rafters, or around the edge of a tile
- Felt that is torn, brittle or hanging in folds between the rafters
- Battens that are dark, soft or crumbling at the ends, or snapped between rafters
- Stained rings on rafters and battens where the timber has been wetted and dried more than once
- Rust on the nails, or tiles that slip along one run of courses while the rest stays put
- A dip or wave in the line of the tile courses when you look along the roof
Rust deserves a closer look. Our short answer on nail sickness on a tiled roof explains why corroded fixings let tiles slide even when the timber is sound.
From outside, a sagging line or a patch of slipped tiles may point to a loft problem. It is not proof. A tile can slip for several reasons, and only the loft, plus a few lifted tiles, shows whether the battens beneath have gone.
When the cause is not clear, we explain what we want to lift, agree it with you first and photograph what is under it. You see the batten and the felt on your own roof before any price is given.
Choosing an underlay and keeping it ventilated
Underlays come in two families that behave differently. HR means high resistance: the underlay is not vapour-permeable. LR means low resistance, a breather-type underlay that lets moisture vapour through. The two look alike from above, so the data sheet for the product laid is what tells you which you have.
The family you choose sets the ventilation the roof needs. For a cold roof, one with insulation at ceiling level and an uninhabited void, Marley gives the following under BS 5250.
| Underlay | Ventilation |
|---|---|
| HR, pitch 15 degrees or less | 25mm along the length of the eaves |
| HR, pitch over 15 degrees | 10mm along the length of the eaves |
| LR, well-sealed ceiling, air-permeable covering | Normal eaves construction (3mm), provided the UKAS third-party certification is fully met |
Marley adds that with an LR underlay and a normal ceiling, the roof void should be ventilated at the eaves, and where the covering is air impermeable the batten space should be ventilated as well. These are Marley's figures for its products and for BS 5250, so the data sheet for the underlay you are given is the document to check.
Eaves ventilation is a detail that is easy to block, because new insulation pushed hard against the eaves can close it. From outside, check that any soffit vents are clear of paint and debris. Our guide to pitched roof underlay and ventilation covers the whole question.
BS 5534, mortar and what the standard asks of battens
The standard that applies to slating and tiling is BS 5534:2014+A2:2018. Marley says "Installing to BS 5534 isn't required by law" and lists its contents as including batten selection, methods of fixing and wind uplift calculations. It covers normal re-roofing work and repairs as well as new roofs. The 2018 amendment added guidance on underlays, including how their wind uplift resistance is classified, and a revised clause on temporary weather protection before the main covering goes on, to shield underlays from UV light.
The 2015 amendments changed how ridge and hip tiles are secured. Marley says they "made it clear that mortar could no longer be relied upon as the only means of securing the roof covering". Single-lap tiles and ridge and hip tiles had to be mechanically fixed whether or not mortar was used, and tiles at the perimeter of the roof had to be fixed twice. Fixings matter as much as the timber they go into. Mortar stays on the roof, but it cannot be the sole fixing.
BS 8612 is the specification for the dry-fix systems used at ridges, hips and verges. A new batten layout therefore has to suit the covering, the fixing method and the way the ridge and verge are to be finished.
On an older or listed house, the picture changes. Fixing methods for traditional materials can conflict with the standard, so the covering, the method and the permissions are settled together before anything is ordered. Our guide to whether to re-tile or repair a pitched roof sets out how that decision is reached.
Approval for renewing battens and felt in England and Wales
The answer changes at the border and with the extent of the work. Each rule below belongs to one side only.
- In England, the Planning Portal applies two tests to a re-roof. Where "Less than 25 per cent of the total 'building envelope'" is affected and "Less than 50 per cent of the roof is affected", an application is not normally required.
- In England, the Portal also says approval is needed where a heavier covering adds weight "by 15 per cent or more".
- In England, AD L 2021 sets values for existing roof elements in Table 4.3, with a threshold of 0.35 and an improved figure of 0.16. Ask building control whether your job brings them into play. A new Approved Document L takes effect in England on 24 March 2027.
- In Wales, the Welsh Government says of re-roofing: "In most situations, this work will need Building Regulations approval."
- In Wales, the same page adds that "the work to re-cover a roof should also include for improving the thermal insulation properties of the roof".
- In Wales, where the new covering is a different material from the original, the Welsh Government describes approval as "likely to be needed".
On either side the question goes to building control, which means the council's building control service or a registered building control approver. We check before work starts, and what it says is reflected in the price you are given.
A change of covering is also a planning question for a listed house, or a house in a conservation area, and the council is the body to ask there.
Deciding when to renew, and what sets the price
Battens and felt are reached only by removing the tiles. That is why renewal is bundled with a re-tile, and why a repair that opens one section can show whether the rest is worth saving. We recommend replacing a covering only when repairing it would not last, and a repair when that is the better buy.
What sets the price of a renewal:
- the area of roof being stripped, and its pitch and access
- the covering going back, whether the existing tiles are reused or new ones laid
- the underlay chosen, and the ventilation the roof needs
- how much timber proves sound once the tiles are off
- scaffold, which is included in our written quote; see whether each quote you compare includes VAT and scaffold
As third-party guides, Which? (November 2025 survey, ex VAT) gives "£7,000-£21,000" for replacing an entire roof, for the average three-bedroom house. HomeBuilding (30 September 2025) gives £10,000 to £15,000 for a 65 m² semi in plain concrete tiles. They describe typical jobs. What your own roof needs is found at the survey.
If some tiles are sound, they can be taken off, set aside and relaid over the new timber and felt. We photograph them as they come off and count the cracked ones, so the number of replacements is known before the written price is agreed.
The photographs and a single written total price come to you after the survey.