01432 610152 Get a quote Call 01432 610152

Lead code for flashings

What lead code is used for flashings?

Royston Lead lists three codes for flashings, Codes 4, 5 and 6, and the right one for your roof is chosen joint by joint at the survey.

In brief

Royston Lead's table names Code 4 (blue), Code 5 (red) and Code 6 (black) for flashings, with thicknesses of 1.80 mm, 2.24 mm and 2.65 mm. Code 3 is marked for soakers only, and Codes 7 and 8 are listed for heavier work such as valley, parapet and dormer lead. The code we propose for a given flashing depends on the joint, and it is written on the quote.

The three codes the table lists for flashings

Flashing is lead dressed over the joint between a roof and a chimney or wall, so that the gap is covered. Royston Lead's cast-lead brochure marks the codes for that use with the letter B. Three codes carry it.

Lead codes listed for flashings
CodeColourThicknessWeight
4Blue1.80 mm20.41 kg/m2
5Red2.24 mm25.40 kg/m2
6Black2.65 mm30.05 kg/m2

Code 3, in green, is not on the list: the brochure says it is "Recommended for lead soakers only". Codes 7 and 8, in white and orange, are not on it either, because the brochure puts them against the heavier work of valleys, parapets and dormers. So the choice for a flashing lies among three, and each step up is a little more metal for the same job. The step from blue to red adds 0.44 mm, and from red to black 0.41 mm, which sounds small but shows in how the sheet bends, how it weighs and what it costs to buy. Ask any firm which of the three it means.

What a flashing asks of the lead

A flashing has two awkward edges. The top edge is pushed into a joint cut in the brickwork or stone and held there. The bottom edge lies over the slates or tiles, or over a soaker, and has to stay put while the roof and the wall move a little against each other. Lead is used because it can be pressed to the shape of the joint and stay there.

The thickness matters in a few practical ways:

  • a thinner sheet is easier to fold into a tight stepped line
  • a thicker sheet holds its shape better across a long, plain run
  • a heavier sheet needs more secure fixing and a sound joint to sit in
  • on an old building, thickness is part of how the new lead looks beside the old

None of that points to one code as right everywhere. It is why the choice is made on site. Flashings sit next to soakers at a wall, and the two pieces have their own listing in the table, set out on the page about what lead code is used for soakers. How the pieces fit together is in soakers or step flashing.

Settling on a code at the survey

The brochure says which codes are listed for a flashing. It does not say which one belongs on your chimney, so that is decided by looking. When we survey, we note:

  • the length of each flashing, and how many steps or turns it makes
  • the state of the masonry joint it must be tucked into
  • the covering it laps over, and whether soakers lie beneath it
  • the thickness of the old lead, which we can see at a cut edge or a split
  • whether the house is listed, in which case the council is asked about changes first

A thicker code is not automatically the better buy. It adds weight and cost, and a joint that is badly pointed will fail whatever the sheet is made of. On the MyJobQuote page, lead flashing that is correctly installed "can last for over 80 years". That wording is a hedge and it does not name a code, so no thickness is promised a lifespan by it.

We photograph the old lead and the joint, and the code we propose goes on the quote beside each flashing. The lead roofing page shows the other places lead is used.

Standards, listed buildings and the written price

Two standards come up around lead, and they do different things. In England, Approved Document C cites BS 6915 for lead. BS 6229:2025 deals with flat roofs finished in flexible membranes, and it never covers lead. Neither one picks the code for a flashing. The Royston Lead table is where the codes and their uses are set out.

On a listed building the council has the say over any change to the roof. In England the Planning (Listed Buildings and Conservation Areas) Act 1990 section 7 covers works that would affect character. In Wales the Historic Environment (Wales) Act 2023 sections 88 and 89 do the same job. Changing to a different thickness of lead may or may not count as that kind of change, so we ask the council first.

The price follows the same logic as the code. Our figure is a single written total, and any scaffold has been counted into it. Check that any other quote says whether VAT is included, and that it names the code for each flashing, not only the word lead.

Related questions

Is Code 3 lead ever used for a flashing?

Royston Lead's table does not list it for flashings, and marks Code 3 as recommended for lead soakers only. If a quote proposes the thinnest code for a chimney flashing, ask the firm why, and ask which table it is working from so you can check the same line.

Does a heavier code mean a longer-lasting flashing?

Nothing in the published figures links the two. MyJobQuote's line, that lead flashing put in correctly "can last for over 80 years", is tied to the installation, not to a code. A well-formed joint in sound masonry matters too, along with the thickness of the sheet, and the survey looks at all three together.

Get your free roof quote

Tell us about the roof and we will arrange a survey.

10-year workmanship guarantee, in writing