In brief
2.24 mm. Royston Lead's cast-lead sheet table gives Code 5 a thickness of 2.24 mm and a weight of 25.40 kg per square metre, and marks it red. It sits between Code 4 at 1.80 mm and Code 6 at 2.65 mm. The same table lists Code 5 for flashings, pitched valley gutters, the larger parapet, box and tapered gutters, and dormers.
Code 5 in millimetres, kilograms and colour
Lead sheet is described by a code number, and each code stands for a thickness. Code 5 is 2.24 mm, a little over two millimetres of metal. The Royston Lead brochure, which lists the cast-lead codes used on roofs, also gives a weight and a colour for each code, and the table below pulls out the Code 5 line. Reading across the row gives everything a quote needs to say about the sheet itself: how thick it is, how heavy it is per square metre, and which uses the maker lists it for.
| Property | Code 5 |
|---|---|
| Thickness | 2.24 mm |
| Weight | 25.40 kg per m² |
| Colour | Red |
| Use letters | B, C, D and E |
The use letters are Royston's own and are explained in the next section. The weight is for one square metre of sheet, so a larger piece weighs proportionately more, and our page on how heavy roofing lead is gives the weights for every code.
The thickness is a figure for new sheet. Lead that has been on a roof for decades is measured at a clean cut edge when its code matters, because the face of old lead is weathered.
Where Code 5 is used
Royston's table lists the uses of each code with a letter against it, and the letters are the quickest way to see where a code belongs. Code 5 carries four of those letters:
- B: flashings, the strips that seal a roof against a wall or chimney
- C: pitched valley gutters, the lead channel where two sloping roofs meet
- D: the larger gutters behind a low wall, between roofs or running to a fall
- E: dormers, the small roofed windows that stand out from a slope
Code 5 does not carry the letter A. That letter is for soakers, the pieces tucked beneath tiles or slates along a wall, and Royston lists Code 3 and Code 4 for them. Code 3 is marked "Recommended for lead soakers only", which means it is not meant for the other details.
So a single code suits a chimney flashing, a dormer cheek and a pitched valley alike, and that is the reason a quote can name Code 5 more than once. Our page on which lead code suits flashings compares it with the codes either side.
Code 4 and Code 6 beside it
The codes next to Code 5 in the table are close in thickness. Code 4 is 1.80 mm and Code 6 is 2.65 mm, so Code 5 is 0.44 mm thicker than the first and 0.41 mm thinner than the second. Those are small differences on a ruler, and they add up to a noticeable difference in weight over a large area.
| Code | Thickness | Weight | Use letters |
|---|---|---|---|
| 4 | 1.80 mm | 20.41 kg per m² | A, B, C, E |
| 5 | 2.24 mm | 25.40 kg per m² | B, C, D, E |
| 6 | 2.65 mm | 30.05 kg per m² | B, C, D, E |
Code 4 is the only one of the three that carries the soaker letter, while Codes 5 and 6 are the pair that reach the larger gutters. The thicker the sheet, the more it loads the deck beneath it. A code is picked for the detail in front of us, never by taking the heaviest on the shelf, and we set the choice out at the survey.
Checking the code on your own roof
A quote for lead work should name the code. If it says only "lead", ask which one, because the thickness changes both the weight on the roof and the quantity of metal in the job.
For lead already on a roof, the code is read from the sheet itself. We photograph the old lead at a cut or lifted edge, measure its thickness there and match the new sheet to the detail, and not only to the old figure. Where an earlier repair used a thinner code than the detail needed, the photographs show it, and the new quote names the code that the detail calls for. That way a thickness is something you can read on paper before the lead goes on the roof, and check again against the finished work.
The codes are identical in England and in Wales, but the route for a standards question differs. In England, a registered building control approver or the council's own team can say what they expect; for a Herefordshire address that is Herefordshire Council Building Control on 01432 261938. In Wales, the council's building control service and the registered approvers answer the same question.
Everything else on lead sheet is gathered under lead roofing.
