01432 610152 Get a quote Call 01432 610152

Bays, porches, dormers

Small flat roofs over bays, porches and dormers

A bay, a porch and a dormer each carry a small flat roof that is harder work than its size suggests. This guide covers how they are built, how they fail and what suits each.

Horizon Roofing Hereford 9 min read

Not every flat roof is a garage or an extension. Some houses carry a few square metres of flat roof in odd places: the top of a bay window, the canopy over a front door, the lid of a dormer that sticks out of the slope. Each is small enough to ignore from the pavement and awkward enough to give trouble indoors.

A bay roof is the flat or shallow top above a window that projects from the wall. A porch roof covers the entrance, and may be a lean-to, a flat deck or a small gable. A dormer is a window built out of the roof slope, with its own flat or pitched roof and two side walls called cheeks. All three share the same problem: a tiny area surrounded by wall, window frame, tiles and gutter, all of which have to be made watertight against one another.

The sections below explain why these roofs fail at their edges, how the coverings compare, where the dormer meets the main roof, and which Building Regulations tests apply in England and in Wales. They sit under our flat roofing service, and the guide to upstands, kerbs and edge trims explains the junction details they rely on.

Three small roofs and what each one touches

Size is the first thing to understand. A bay or porch roof might measure a couple of metres each way, so nearly all of it lies close to a wall, a frame or an edge. There is hardly any open field of membrane, and that changes how the roof behaves: the edges are not a detail on the roof, they are most of the roof. A fault of a few millimetres at one corner is therefore a fault in a large share of the waterproofing.

What each small flat roof meets
RoofWalls and frames it meetsWhere the water goes
BayThe house wall above the window head, and the side faces of the bayA small gutter on the bay front, or a drop to the sill
PorchThe house wall, plus a post or a brick column at the frontA short gutter and one downpipe, or straight off the edge
DormerThe cheeks on both sides and the face above the windowOnto the main roof, or into a gutter on the dormer front

Whatever the roof, it carries the same chain of parts: a deck of boards, a waterproof covering, upstands at each wall junction, a flashing above those upstands and an edge that throws water forward. When a small roof leaks, one link in that chain has gone, and the job is to find which. Our torch-on felt roofs guide covers one of the coverings in detail.

Why small roofs leak at the joints

A small flat roof has a higher share of joints per square metre than a large one, so there are more places for a seam to open. Several faults repeat from house to house.

  • A flashing that was fitted tight to a wall and has since lifted as the pointing weathered.
  • A bay that has moved slightly away from the main wall, tearing a rigid seal.
  • A gutter so small that a handful of leaves blocks it, sending water back over the edge.
  • A deck of timber that has taken damp, because the covering split years before anyone saw it.
  • A porch roof laid dead flat, so water stands on it and works into every small gap.

Ponding, the pooling of water on the roof surface after rain, matters more on small roofs than it seems. NFRC says BS 6229:2025 sets "a minimum 1:80 finished fall". A porch that is built level will hold a shallow pool, and the membrane there lives wet. Our guide to GRP fibreglass flat roofs shows how a one-piece laminate copes with those pools.

A bay roof also has the window below it. Rain that finds the wall behind a failed flashing runs down the face of the frame and appears as a stain on the ceiling or as damp round the window head. The visible symptom sits inside the room and the cause stands a metre above it, which is why we check the roof from outside as well as the ceiling from within.

Choosing a covering for a small roof

The options for a small roof are the same as for a large one, but the balance of cost, skill and detail shifts. The sources give lifespans as ranges, and they do not agree, so we show both.

Typical lifespans, as published
CoveringHomeBuildingOther source
Felt (torch-on)10-15 yearsLess: 10 to 20
EPDM rubber25-30 yearsLess: 30 to 50
GRP fibreglass25-30 yearsLess: 25 to 40
Lead60-100 yearsLess: 50 to 100

Zinc is a fifth choice that suits small roofs and dormer tops. VMZinc, the maker, states that zinc roofing, if correctly designed and installed, "can last in excess of 100 years". That is a manufacturer's claim, not an independent one.

For a bay or porch, the usual question is whether to use a sheet system or a metal. A sheet of rubber or a one-piece GRP laminate gives a roof with few seams. Lead takes more skill to lay but suits the shapes of a period house. Royston Lead's table lists "E Dormers" among the uses for Codes 4 to 8, and it lists Codes 5 to 8 for parapets and box gutters. We choose the covering to match the roof you have. Spans, falls, the shape of the edges and the weight the structure can carry all narrow the field, and we set the trade-off out in writing before work starts. A bay roof carried on old timber, for example, may not suit a heavy covering, and a dormer with lead cheeks may suit lead on top.

Dormer cheeks and the join to the main roof

A dormer is the most complex of the three. Its flat roof is small, but the cheeks, the face and the join to the main slope each have a weatherproofing job to do.

The cheeks are the side walls. They may be clad in lead sheet, in slate or tile hung on battens, or in render or boarding. A cheek clad in lead is made from sheets joined by folded seams that allow movement, which is why lead is chosen for them. Where the cheek meets the main roof, a row of soakers, little folded pieces of lead slipped beneath every row of tiles or slates, forms a stepped seal. The principle is the same as on a chimney, and our guide to chimney flashing leaks shows it in use.

At the back of the dormer, the flat roof meets the main roof at the top. A lead apron or a lead-lined tray carries water from the flat roof across the slope. If that tray is short or has lifted, water runs behind the dormer and appears as a stain on the room's back wall. At the front, the roof edge throws water clear of the window face.

Insulation is another point on a dormer. The flat roof forms the ceiling of a room, so any new roof needs the insulation values set out in the rules below, and the build-up has to be ventilated or detailed so damp air cannot collect inside it. Condensation inside the roof can look like a leak, and the survey tells the two apart.

The rules when a small roof is renewed

The rules differ between England and Wales, and a small roof does not escape them.

  • The Planning Portal's test for England: normally no application is required where "Less than 25 per cent of the total 'building envelope'" and "Less than 50 per cent of the roof" is affected.
  • Welsh Government guidance for Wales on re-roofing reads: "In most situations, this work will need Building Regulations approval."

For a newly built roof element on an existing dwelling, Approved Document L for England (Table 4.2) sets 0.15 for the roof. In Wales, Table 4.1 sets 0.13 for the roof. England and Wales agree on the glazed parts: a roof window must reach 1.4 or WER Band B, while a rooflight has to reach 2.2. Where only the waterproof membrane is replaced, the work counts as renovation: in England Table 4.3 gives 0.35 as the threshold and 0.16 as the improved value; in Wales Table 11.1 gives 0.16, and not worse than 0.35 where 0.16 is not feasible.

A new dormer is a planning question first. In England, a dormer is not permitted development on article 2(3) land, which covers conservation areas, National Parks and National Landscapes. In Wales, the bar sits on article 1(5) land. A listed house needs listed building consent as well, and whether an Article 4 direction applies is a question for the council. Approved Document L 2026 starts on 24 March 2027 in England and a new Welsh edition on 4 March 2027, so we check the edition in force when we quote.

What a small roof costs and what we check

Bay, porch and dormer roofs are priced job by job, so the figures below describe flat roofs in general rather than yours. MyJobQuote gives an average for replacing a whole flat roof of between £1,500 and £6,000 in 2026 (20 October 2026), felt at £80 to £120 per m² installed, and rubber at around £1,050. Per-square-metre figures are for a given area and we never multiply them into a total. Checkatrade quotes £120 to £170 per m² for EPDM repairs and £130 to £180 per m² for GRP repairs (June 2026, ex VAT, up to 3 m²).

On a small roof the price is set by access, the number of junctions, the condition of the deck, the covering chosen and any scaffold. One total price goes into writing after the survey.

The survey runs through a fixed list:

  • the deck, from below if the ceiling allows, for dark or soft timber
  • each upstand, flashing and soaker where the roof meets wall or tile
  • the edge, the gutter and the downpipe, for blockages and level
  • the window head or frame below, for staining and rot
  • any pipe, vent or rooflight passing through

We photograph what we find, show you the pictures and explain the repair that fits. If the roof needs re-covering, that is what we say; if a flashing and some pointing will do, we say that instead. Once the work is done, the area is swept and every offcut goes off with us.

Small flat roofs: your questions

Can a bay window roof be re-covered without removing the window?

Yes, the window can stay in place. The covering is stripped from the deck, any damaged boards are replaced, and the new covering is dressed up to the wall and over the window head. We check the head and frame first, because leaks can show there before they show on the ceiling.

Does a porch roof need Building Regulations approval when re-covered?

In England, the test above decides, and a small roof sits well inside it. In Wales, the guidance quoted above points to approval in most situations, so we ask the council or a registered building control approver first. Either way you get the answer in writing.

Which covering suits a small dormer roof?

That depends on the dormer. A flat top with simple edges can take rubber or GRP, while a dormer with lead cheeks and a stepped join to the tiles can suit lead on the top as well, so the metals match. We explain our choice and the trade-off in the survey report.

Get your free roof quote

Tell us about the roof and we will arrange a survey.

10-year workmanship guarantee, in writing