01432 610152 Get a quote Call 01432 610152

Roofers in Puddlebrook

Valleys, gutters and rooflines on Puddlebrook homes, with a Grade II listing close by.

Your report carries a photograph of every fault found, and a single price is set out in writing after the visit has been made.

Get a free quoteCall 01432 610152

Where a Puddlebrook roof collects its water

  • Older cottages with weathered clay tile roofs and brick chimneys behind a flint wall
    Valleys between two slopesRain off both slopes meets in the valley, so its lining is checked first.
  • Slate roofs and chimney stacks along a red brick Victorian terrace
    Gutters pulling from the fasciaA dipped length stands full and soaks the fascia beside it.
  • Newer homes with grey concrete tile roofs along a curving estate road
    Older soffits and asbestosSoffits on a pre-2000 building are treated as possible asbestos.

Where Puddlebrook sits

Puddlebrook on a street map, with a dashed circle around the town and the nearest towns we cover. Tiles © Esri; map data © Esri, HERE, Garmin, OpenStreetMap contributors.

Puddlebrook roofs, valley to listed wall

Following the water on a Puddlebrook roof, from valley to gutter to listed wall

Puddlebrook roofs shed their water in a set order, and so does our survey. The valley between two slopes is first, then the eaves, gutter and soffit where the water leaves, and last the Grade II listing and the conservation areas nearby.

A drawn cut-away section through a Herefordshire border house: the front of the main roof is cut open to show the rafters, underlay, battens and slates, beside a black-and-white timber-framed gable. Numbered, from the ridge down: 1 Valley; 2 Gutter and soffit; 3 Listed wall.

Fig. 1 Puddlebrook section: lead valley, eaves gutter and listed wall, numbered 1 to 3.

Callout 1 of 3

Lead and tile valleys on Puddlebrook houses

Look at a Puddlebrook roof from the lane and the valleys are the inside corners where one slope runs into another, forming a trough. Rain from both slopes funnels along it, which is why we trace the water from here first. A valley may be lined with sheet lead or built from tiles cut to meet along the line. From the ladder we look along the trough for gaps, for debris sitting in it, and for lead that has lifted at the edges or cracked across a fold.

Lead in a valley gutter is graded by the Royston Lead table, where Codes 4, 5, 6, 7 and 8 appear against pitched valley gutters, and Code 3 is "Recommended for lead soakers only". A sheet too thin for the job can show the strain early, because thin lead wrinkles where the flow is heaviest. MyJobQuote says correctly fitted lead flashing "can last for over 80 years", and that hedge belongs to flashings, so the valley is judged on current condition rather than age.

Blockage can do as much harm as a split. Moss, seeds and grit from the tiles gather in the trough and build into a dam, and the water backs up beneath the tile edges on both sides. We clear what we find and photograph the lead beneath, so you can see its state before deciding anything, with a close-up of the worst fold because a photograph shows a hairline split better than a description does. Sound lead stays put and the tiles beside it are rebedded. Split lead is replaced by the length rather than patched, because a patch puts a joint in the one place the water runs hardest.

The loft shows what the trough has been doing. Staining on the rafters beside the line, or a damp patch on the boards, tells us water has been getting through even where the lead looks whole from outside. Some valleys sit mid-roof, out of reach from the eaves, so the ladders are moved and a roof ladder spreads our weight over the covering.

Where a valley ends against a chimney, a dormer or a roof window, that junction needs a flashing of its own, and the survey records it as a separate item with its own photograph. Our lead roofing page describes the lead work in more detail. When a valley has been relined, the old lead leaves with us and the tiles sit square along the new line.

A lead valley, as we find it

SoundLead flat in the angle, clear of grit, edges lying tight
Needs workSplit at a fold, lifted edges, moss damming the flow

Callout 2 of 3

Gutters, fascia and soffit at a Puddlebrook eaves

From the valley the water travels down the slope to the eaves, where the gutter takes over. The installation advice from Brett Martin is a fall of "1mm for every 600mm", so that the water keeps moving towards the outlet. A length that has dipped between its brackets stands full, and the standing water works into the fascia, the board holding the gutter's screws, and into the rafter ends behind it. With a spirit level we check the fall, test each bracket by hand, look for drips at the joints and then press the board behind.

Soffits close the underside of the overhang, and in a cold roof they carry the air that keeps the loft dry. Marley's note for roofs laid with HR underlay asks for "10mm along the length of the eaves" on pitches of more than 15 degrees, and HR underlay of that type does not let vapour through. A soffit painted shut or boxed in without a vent can leave the air nowhere to go, so we look for it from inside the loft as well as from the ladder.

Soffit boards on older buildings call for care. HSE advises assuming asbestos is present when a building dates from before 2000, whether it was built or refurbished then. Removing white soffit panels of asbestos insulating board is, in most cases, licensed work, so it goes to a licensed firm and not to us. Asbestos cement is a different case: taken off carefully and left unbroken, it counts as non-licensed work, with the waste carried off in a skip that locks. A test comes before any board is touched.

Downpipes get a look too, because a parted joint or a blocked foot sends water down the wall instead of into the drain. Where the roofline is replaced in plastic, one retailer of uPVC boards says they can keep reliable performance for between 20 and 40 years. As an interested party it gives a range and not a promise, and we treat it that way. Our guttering, soffits and fascias page covers the work. Scaffolding that stands over the road side is licensed, and we arrange the licence with our scaffolder.

What we test along a Puddlebrook gutter

Fall
Run checked against 1mm for every 600mm, per Brett Martin
Brackets
Tried by hand along the whole length
Joints and outlets
Looked at for drips, stains and blockage
Fascia board
Pressed behind the gutter for soft timber
Soffit vent
Checked for air reaching the loft
Fig. 3 Gutters and downpipes, drawn close

Callout 3 of 3

Beechwood and the conservation areas close by

Callout three is the wall, and near Puddlebrook that brings in Beechwood, a building listed Grade II (list entry 1299202, first listed 1 October 1976). If your house is listed, section 7 of the Planning (Listed Buildings and Conservation Areas) Act 1990 treats roof work as controlled where it would affect the building's character, and the consent comes on top of whatever permitted development you hold. A listing covers whatever building its entry names, so a neighbour needs an entry of its own, and we look yours up before anything is priced. If you want to check for yourself, the entry number is the thing to quote when you ask the council a question.

Both Mitcheldean Conservation Area and Ruardean Conservation Area sit close to Puddlebrook, with the boundaries held by Forest of Dean District Council. The council's map shows whether your own address lies in either one, or in another area altogether. It is also the office to ask about any Article 4 direction on your street, and the question is worth putting before you order a new covering or alter the look of a roof, because a direction takes away rights you would otherwise hold without asking.

Roof windows and dormers raise planning conditions that are set out in our planning guide for roof windows. For Building Regulations in Puddlebrook, the Forest of Dean District Council building control team can be reached on 01594 812315, and a registered building control approver is the other route. Heavier coverings, new roof structure and insulation changes can all go to one or the other. Approved Document A calls a change of more than 15% in roof loading significant, and for that reason a heavy covering over a lighter one gets a structural check beforehand.

To reach Puddlebrook from central Hereford is 19.8 miles by road to the south-east, a drive of about 37 minutes. We bring the ladders and photograph what we find before any quote is written. For houses with a listing or a conservation area nearby, our listed and heritage roofing page describes the steps.

Beechwood and its neighbours

Does Beechwood's Grade II listing cover the houses around it?

No. A listing belongs to the building named in its list entry. A neighbour may have an entry of its own, and the national list, searched by address, is the way to find out.

Puddlebrook roofs: valleys, gutters and soffits

What should be checked in a lead valley on a Puddlebrook house?

We look along the trough for splits at the folds, edges that have lifted, and grit or moss damming the flow, then go into the loft for staining beneath it and on the rafters beside it. Royston Lead lists Codes 4 to 8 for pitched valley gutters, so a very thin sheet is suspect. Photographs of the valley as found go in your report before any price is given.

Can a sagging gutter harm the fascia of a Puddlebrook house?

Yes. Brett Martin advises a fall of 1mm for every 600mm, and a run that has dipped holds water against the fascia board and the rafter ends behind it. Over time the board softens and the paint lifts. We test the fall, the brackets and the joints, then press the board behind the run, and photograph the worst length, and tell you whether a re-hang or a replacement is the honest answer.

Could the soffits on my Puddlebrook house contain asbestos?

For a building from before the year 2000, built or refurbished then, HSE's starting position is to assume it holds asbestos, so for an older house the answer is that it may, and a test settles the question before any board is touched. Soffits of white insulating board are mostly licensed work, and we hand those to a licensed firm. Asbestos cement taken off carefully, without breaking, counts as non-licensed work; its waste is loaded into a lockable skip. Testing comes before disturbance.

What does Beechwood's Grade II listing mean for roof work near Puddlebrook?

Beechwood is listed Grade II under list entry 1299202. Section 7 of the 1990 Act applies to the listed building itself. Works that touch its character call for consent from Forest of Dean District Council, with permitted development rights remaining beside it. Your own house needs a list entry of its own to be covered, and we check this at the survey.

Which conservation areas lie close to Puddlebrook?

Mitcheldean Conservation Area and Ruardean Conservation Area are nearby, and Forest of Dean District Council holds their boundaries. The council's list shows whether your address sits in either one or in another area. Put the Article 4 question to the council as well, before ordering a different covering: a direction can withdraw specified permitted development rights across an area the council has defined. A written reply from the council is worth keeping with the survey photographs.

When does Puddlebrook roof work go through Forest of Dean building control?

The council's building control team, on 01594 812315, or a registered building control approver, handles work that needs Building Regulations approval. For re-roofing in England, the Planning Portal sets the line at less than 25 per cent of the building envelope and less than 50 per cent of the roof, and within that line no application is normally expected. A heavier covering needs approval and a structural check, whatever the proportion.

Start a Puddlebrook survey at the valley

Tell us about the valley, gutter or soffit that concerns you, and our survey will finish with a price on paper.

10-year workmanship guarantee, in writing