Callout 1 of 3
Timber framing and what it asks of a roof
Churcham's older buildings include timber-framed ones. The Victoria County History, in its 1972 account of the parish, describes Church Lane Farm as two ranges at right angles to each other, "both originally timber-framed". A frame like that carries a roof in a particular way, so callout one goes under the covering. The wall plate is the beam that runs along the top of the wall, the rafters slope from it up to the ridge, and everything the tiles weigh passes down through those joints. We look at all three from the loft, with a torch.
What we are hunting for is daylight, damp and softness, and each one is written down against the part of the roof where it was found. Daylight through the covering marks a gap that rain also finds. Dark staining on a rafter or the underside of the boards shows where water has been running. A blade pressed into the end of a rafter where it sits on the wall plate tells us whether the timber is still firm. If a timber is soft, or a joint has moved, the question stops being a roofing one: structural timber goes to a structural engineer or a timber specialist, and the covering waits for that answer.
Whatever the frame, the covering on it is recorded separately, whether clay, concrete, stone or slate, and how it is fixed. A frame that has moved over generations may not carry a roof that is perfectly straight, so units are matched to the line of the timber, not to a level. Before any strip begins, the old covering is photographed where it lies and the battens are counted against the rafters, so the new layout follows the frame's own spacing. Our pitched roofing page describes how a re-cover is staged around a frame like this.
Weight matters more on an old frame. According to the Planning Portal, a new covering that weighs 15 per cent or more above the old one needs Building Regulations approval. Swapping a light covering for a much heavier one can cross that line, so approval and a structural check come before any order is placed with the merchant. The Planning Portal sets its own test for England, under which a re-cover is not normally submitted anywhere while it affects less than 25 per cent of the building envelope and less than 50 per cent of the roof is touched.
Checked in a Churcham loft
- Daylight showing through the covering
- Staining on rafters and underside boards
- Rafter feet where they meet the wall plate
- Joints that have opened or shifted
- Wet insulation or damp patches
On an old frame, what the covering weighs matters as much as what it looks like.