Callout 1 of 3
Starting in the loft: frames, plates and rafter feet
A survey here begins indoors. The roof of an old timber-framed house is held up by a structure that has been moving since it was raised, so the loft tells us more than the slope outside. The Royal Commission's 1934 inventory covered the buildings numbered 2 to 6 in Birley parish as a group, describing them, unless it said otherwise, as seventeenth-century, timber-framed and of two storeys. Nothing in that line fixes what lies above those frames now, but it shows the kind of structure a repair has to respect.
We look for rafter feet that have gone soft, wall plates stained dark by old leaks and daylight where there should be none. Rafters are the angled timbers the covering rests on, and they can be sound for most of their length and decayed only at the foot, where the wall plate holds moisture. A screwdriver pressed into a suspect timber tests it, and the result is photographed beside a tape so the depth of any rot is clear.
Frames move, so the covering above them cannot be forced flat. A roof that sags between two walls follows the structure beneath it, and a new covering laid over that line will keep it. We therefore do not straighten a ridge that was never straight. Where timber has to be cut out, the sound wood either side is checked for further decay before a new section is spliced in, and the carpentry is left open for inspection wherever building control asks to see it.
Ventilation belongs in the same visit. Marley says a cold roof with high-resistance underlay needs 25mm along the length of the eaves for pitches of 15° or less, and 10mm for pitches of more than 15°, because that underlay is not vapour-permeable. The loft shows whether those gaps have been blocked by insulation pushed too far into the eaves.
Herefordshire Council Building Control, on 01432 261938, covers an address in the village, and a registered building control approver is the private route. If structural timber changes, one of them is told before the work goes ahead. Our roof inspections and surveys page sets out what a loft-and-roof survey records and how the report is laid out.
Recorded in a Birley loft
- Rafter feet
- Tested with a screwdriver and photographed beside a tape
- Wall plate
- Checked along its length for staining
- Battens
- Nails and condition seen from below
- Eaves gap
- Whether insulation has blocked the airflow
A rafter foot in a Birley loft
Rot at the rafter foot is found from the loft, not from the lane.