In brief
For permitted development, a roof window must not protrude more than 0.15 metres beyond the plane of the original roof slope in England, measured from the perpendicular with the external surface. In Wales, Class C says 15 centimetres. In both countries the highest part of the alteration may not be higher than the highest part of the original roof. A taller alteration needs planning permission.
What the two limits say
Both countries use Class C of Part 1 of Schedule 2, which covers "any other alteration to the roof of a dwellinghouse". Each sets a depth in its own units, plus a height rule:
| Country | Limit on projection | Height rule |
|---|---|---|
| England (GPDO 2015, C.1(b), C.1(c)) | Not more than 0.15 metres beyond the plane of the slope | Not higher than the highest part of the original roof |
| Wales (GPDO 1995, C.1(a), C.1(b)) | Not more than 15 centimetres beyond the plane of the slope | Not higher than the highest part of the original roof |
The distance is the same, 150 millimetres, on both sides of the border. Only the way it is written differs. The English order adds how to take the measurement: "when measured from the perpendicular with the external surface of the original roof". The Welsh order gives the figure without that phrase. Either way, it is the finished window that is measured, including its frame and any fixing that sits above the covering, and not the glass alone.
Measuring it at right angles to the slope
The measurement runs straight out from the roof surface, not up from the ground. On a steep slope that line is short, so a window whose frame lies close to the covering passes comfortably, while a frame carried up on a tall upstand may not.
The plane of the slope is the line drawn by the roof covering. A roof window is designed to sit within that line, with its glazing close to the slates or tiles. The flashing kit laps over the covering, and the frame and sash stand proud of it by a modest amount. The maker's data sheet and fitting instructions give that depth, and it is the figure to hold against the limit.
A window that stands further out than the limit can be one set on a raised kerb or a thick build-up of covering. That matters most on a flat roof, where a rooflight is carried on an upstand. If you already have a model in mind, the depth can be read from its drawing. Our page on whether a Velux can go in a flat roof looks at that case.
Where the limit is not the whole story
Passing the projection test does not settle planning by itself. Further conditions apply, and the two countries word them differently:
- In England, a window on a side slope must be obscure-glazed, and a listed building needs listed building consent as well.
- In England, a conservation area, National Park or National Landscape removes Class B dormers but not Class C.
- In Wales, Class C does not stretch to a roof light on article 1(5) land, so the projection limit gives no help there.
- In Wales, Class C.2(a) asks that the work matches the existing house so far as practicable.
Flats have no householder permitted development rights in England, so a flat's owner applies for planning permission instead. Each condition is set out in our planning guide for England and Wales. If you live in a listed house, a conservation area or a National Park, the council or the National Park Authority can tell you which of these bind your address, ahead of any order for the window. Wherever the house stands, the answer for a flat or a listed building is the council's to give, not ours.
What we do on the survey
From the maker's drawings we work out how far the chosen window stands off the covering, and we check its top edge against the line of the ridge. The rafters, and the slates or tiles around the opening, are looked over and the slope is photographed, so that you can see where the window will sit.
Where the figures run close to the limit, which can happen with a deep frame on a thick covering, you hear about it before anything is ordered, and we look at a lower-profile fixing or a different position. If the window cannot comply, planning permission is the route, and your council can confirm whether it applies to your house.
The figure we give you is written as a total, and it covers the window, the flashing and the finish inside. A straight edge is laid across the slates beside the opening and the tape goes up to the top of the frame, so the number comes from your own roof. Other window jobs are listed under Velux and skylights, and the neighbouring rule on glass is explained in our answer on side-slope glazing.