01432 610152 Get a quote Call 01432 610152

Projection limit

How far can a roof window stick out?

No more than 0.15 metres beyond the plane of the slope in England, and 15 centimetres in Wales, measured at right angles to the roof surface.

In brief

For permitted development, a roof window must not protrude more than 0.15 metres beyond the plane of the original roof slope in England, measured from the perpendicular with the external surface. In Wales, Class C says 15 centimetres. In both countries the highest part of the alteration may not be higher than the highest part of the original roof. A taller alteration needs planning permission.

What the two limits say

Both countries use Class C of Part 1 of Schedule 2, which covers "any other alteration to the roof of a dwellinghouse". Each sets a depth in its own units, plus a height rule:

Projection limits for a roof window under Class C
CountryLimit on projectionHeight rule
England (GPDO 2015, C.1(b), C.1(c))Not more than 0.15 metres beyond the plane of the slopeNot higher than the highest part of the original roof
Wales (GPDO 1995, C.1(a), C.1(b))Not more than 15 centimetres beyond the plane of the slopeNot higher than the highest part of the original roof

The distance is the same, 150 millimetres, on both sides of the border. Only the way it is written differs. The English order adds how to take the measurement: "when measured from the perpendicular with the external surface of the original roof". The Welsh order gives the figure without that phrase. Either way, it is the finished window that is measured, including its frame and any fixing that sits above the covering, and not the glass alone.

Measuring it at right angles to the slope

The measurement runs straight out from the roof surface, not up from the ground. On a steep slope that line is short, so a window whose frame lies close to the covering passes comfortably, while a frame carried up on a tall upstand may not.

The plane of the slope is the line drawn by the roof covering. A roof window is designed to sit within that line, with its glazing close to the slates or tiles. The flashing kit laps over the covering, and the frame and sash stand proud of it by a modest amount. The maker's data sheet and fitting instructions give that depth, and it is the figure to hold against the limit.

A window that stands further out than the limit can be one set on a raised kerb or a thick build-up of covering. That matters most on a flat roof, where a rooflight is carried on an upstand. If you already have a model in mind, the depth can be read from its drawing. Our page on whether a Velux can go in a flat roof looks at that case.

Where the limit is not the whole story

Passing the projection test does not settle planning by itself. Further conditions apply, and the two countries word them differently:

  • In England, a window on a side slope must be obscure-glazed, and a listed building needs listed building consent as well.
  • In England, a conservation area, National Park or National Landscape removes Class B dormers but not Class C.
  • In Wales, Class C does not stretch to a roof light on article 1(5) land, so the projection limit gives no help there.
  • In Wales, Class C.2(a) asks that the work matches the existing house so far as practicable.

Flats have no householder permitted development rights in England, so a flat's owner applies for planning permission instead. Each condition is set out in our planning guide for England and Wales. If you live in a listed house, a conservation area or a National Park, the council or the National Park Authority can tell you which of these bind your address, ahead of any order for the window. Wherever the house stands, the answer for a flat or a listed building is the council's to give, not ours.

What we do on the survey

From the maker's drawings we work out how far the chosen window stands off the covering, and we check its top edge against the line of the ridge. The rafters, and the slates or tiles around the opening, are looked over and the slope is photographed, so that you can see where the window will sit.

Where the figures run close to the limit, which can happen with a deep frame on a thick covering, you hear about it before anything is ordered, and we look at a lower-profile fixing or a different position. If the window cannot comply, planning permission is the route, and your council can confirm whether it applies to your house.

The figure we give you is written as a total, and it covers the window, the flashing and the finish inside. A straight edge is laid across the slates beside the opening and the tape goes up to the top of the frame, so the number comes from your own roof. Other window jobs are listed under Velux and skylights, and the neighbouring rule on glass is explained in our answer on side-slope glazing.

Related questions

Is 0.15 metres the same as 15 centimetres?

Yes, both are 150 millimetres. The English order, GPDO 2015, writes 0.15 metres in Class C.1(b), and the Welsh order, GPDO 1995, writes 15 centimetres in Class C.1(a). In both, the distance is measured out from the roof surface, not up from the ground, and a tall upstand is where the limit can be exceeded.

Can a roof window rise above the ridge line?

Not as permitted development. In England and in Wales, Class C does not cover an alteration whose highest part is higher than the highest part of the original roof. A window in a slope sits below the ridge, so the rule matters mainly for tall upstands, chimneys and dormers.

Get your free roof quote

Tell us about the roof and we will arrange a survey.

10-year workmanship guarantee, in writing