Most gutters hang on brackets from the eaves. A parapet gutter and a box gutter do not. They are channels built into the roof itself, lined with sheet metal, and the water they carry has nowhere to go but the outlet at the end. If the lining fails, the water goes into the building.
A parapet gutter runs along the foot of a roof slope where it meets a parapet, the low wall that stands up above the roofline at the edge of a building. A box gutter is a trough between two roofs or behind a wall, sunk into the structure with timber or masonry on each side. A tapered gutter is a box or parapet gutter that narrows along its length. Royston Lead lists all three in one group of its table, and this guide treats them together.
The sections that follow cover what the gutter is, the codes Royston lists for it, how falls work and which standard does not apply to lead, what the outlet and its overflow need, what access involves and what sets the price. Everywhere a rule differs on the two sides of the border, the sentence names England or Wales. For the rest of the trade, see lead roofing.
How a lead parapet or box gutter is built
The gutter bed is a base of boards fixed between the timbers on each side. The boards slope along the length of the gutter, so water runs towards the outlet, and they are stepped into short lengths. The lead lying on that base is made of sheets that overlap one another and are joined at the steps, called drips, in the same way as a lead valley. The sides of the channel are lined too. The lead turns up the parapet wall, or the roof slope, as an upstand, with a separate strip hung over the top of each one.
A box gutter has a bottom and two sides, and the sides can be tall, so the sheet is large. A tapered gutter is narrower at the high end and wider towards the outlet, because the flow grows as more roof drains into it. A parapet gutter has one slope on one side and a wall on the other.
The detail looks simple from the ground, and it fails for specific reasons:
- an outlet too small for the roof behind it backs up
- an upstand set too low lets water slop over the edge
- a lining creased where the sheet moved allows a crack that wets the boards beneath
- boards that stay wet can rot out of sight for a long time
That is why a survey of a parapet or box gutter includes the inside of the building. Marks on the ceiling or wall beneath the gutter are part of the evidence.
Our guide to the lead valley gutter covers the boards, laps and fillets that parts of this detail share.
Royston codes 5 to 8
Royston Lead's cast lead brochure gives parapet, box and tapered valley gutters a group of their own. It begins at Code 5. Code 4, the code that suits soakers and pitched valleys, is not on the list for this group.
| Code | Thickness | Weight per m² | Colour |
|---|---|---|---|
| 5 | 2.24mm | 25.40 kg | Red |
| 6 | 2.65mm | 30.05 kg | Black |
| 7 | 3.15mm | 35.72 kg | White |
| 8 | 3.55mm | 40.26 kg | Orange |
Four codes are listed, and the choice between them is made on the building. A short gutter on a small porch is a different case from a long gutter on a terrace. Longer runs and larger catchments call for more thought about thickness, and heavier lead means a heavier load on the timbers that carry it.
That load deserves a check before any lead is ordered. Royston's Code 8 weighs 40.26 kg per m², which is more than twice the 20.41 kg per m² of Code 4. On a gutter bed of several square metres, the difference adds up, and the roof timbers beneath it were set out for a building of their own period.
A written quote should name the code, say what the boards beneath are made of, and say why that code has been chosen. If it names only a thickness in millimetres, ask which Royston code that corresponds to.
Falls, and the British Standard that lead sits outside
A gutter needs a fall, which is a slope towards the outlet. For flat roofs covered with membranes, that figure has a standard behind it. NFRC reports that BS 6229:2025 sets "a minimum 1:80 finished fall for general roof areas and internal gutters", and IKO advises designing for 1:40 so that 1:80 is reached. The 2018 edition of the standard was withdrawn on 16 December 2025.
That standard is written for membrane roofs that are fully supported underneath. It does not cover lead. England's Approved Document C (2013 edition) cites BS 6915:2001 for lead sheet, and a lead gutter is judged against that standard, not against BS 6229.
Nor should the figure for a rainwater gutter on brackets be borrowed. Brett Martin gives "1mm for every 600mm" for a guttering system, which describes a plastic gutter on the front of a house and has nothing to say about a built-in lead channel.
No fall figure for lead is given in this guide, because none belongs to the codes above. The fall is a design decision, and the quote should record what has been built in. Three questions help:
- What fall is being laid into the boards, and along what length?
- Which standard is the lead being laid to?
- Where will standing water settle if the fall settles or the lead sags?
If a quote names the membrane standard for a lead gutter, ask the roofer to explain the choice.
Outlets, overflows and what a blocked gutter does
The outlet is the point where the gutter hands its water to a downpipe, or to a rainwater head with a pipe below. In a built-in gutter it is the narrowest part of the whole system. Everything that falls on the roof behind passes through it, and a leaf, a pigeon feather or a clump of moss can stop it.
When the outlet blocks, the gutter fills. A parapet gutter then rises against the upstand, and the next stage is water over the top of the lead and into the wall or the ceiling. A box gutter behaves the same way, with sides that may be low enough to flood over. Tall parapets hide the problem from the ground, because the water stands out of sight until a stain appears indoors.
An overflow, a pipe or slot set a little above the normal water line that discharges clear of the wall, is the safeguard. It shows by running that the outlet has blocked, instead of letting the water go into the building. Not every built-in gutter has one, and adding an overflow is a question for the survey.
At a survey, we check and photograph:
- the outlet and the first length of pipe below it
- the gutter floor for silt, slates, moss and standing water
- the overflow, if one exists, and where it discharges
- the upstands for splits, lifts or a crease where the lead has folded on itself
Clearing the gutter comes first, before any decision about the lead. Which? puts clearing a whole house's gutters at "£75-£350" (November 2025 survey, ex VAT), but that is rainwater guttering at the eaves and says nothing about reaching a parapet.
Reaching a parapet gutter: access and scaffold licences
A gutter behind a parapet is out of reach of a ladder from the ground, and a safe working position means scaffold or a tower. On a house that stands at the pavement edge, scaffold put up on the public highway needs a scaffold licence under s169 of the Highways Act 1980, and we arrange the licence with our scaffolder.
Each highway authority prices a licence in its own unit, so the two figures below describe different charges. They are listed side by side and not compared:
- England, Herefordshire Council: £167 for a maximum of one month, £123 for each further month, and notice of at least 10 days.
- Wales, Monmouthshire County Council: an administration fee of £108, £27 per week to extend, and notice of at least 5 working days.
Other councils in the area set their own figures and notice periods. Ask the highways team for your address, or leave the arrangements to us.
The licence is one reason a gutter job can run past the days spent on the lead itself. Notice periods begin before the scaffold goes up, and the licence has an end date. Any scaffold we need is part of the one written total, so the licence and the period it covers do not arrive as a separate bill.
The same access matters for the inside. A ceiling stain below a gutter means the plasterwork and joists need a look from underneath, and we photograph both sides of the repair.
Repair, relining or renewal, and what sets the price
One split in the lining, a lifted upstand, a blocked outlet: each of those is a repair. A lining cracked in several places, boards that have rotted, or a gutter laid with a poor fall points to renewal. Opening the gutter tells the two apart, which is why the survey comes first and the written total follows it.
What sets the price:
- the run of the gutter and the width of its bed
- the lead code, since a heavier code means more metal to buy and carry up
- the extent of board replacement under the lining
- the height of the parapet and the access it demands
- the state of the upstands and flashings above
- whether the outlet and downpipe also need work
Third-party figures give a sense of scale for a flat roof, which is the nearest category. HomeBuilding gives a lead flat roof "60-100 years", and Less gives "50 to 100 years". Both are typical ranges for sheet lead on a roof laid flat, and neither is a promise about the lifespan of a gutter lined with it. MyJobQuote writes that correctly installed lead flashing "can last for over 80 years", which concerns flashings.
Where a repair will do, a repair is what we recommend. Where the lead has failed along its whole run, the photographs make the case for renewal. Our guide on how long a lead flat roof lasts sets out the lifespan ranges in more detail.