01432 610152 Get a quote Call 01432 610152

BS 6229 edition

Which BS 6229 applies now?

The current edition is BS 6229:2025. The 2018 edition was withdrawn on 16 December 2025, so a specification citing it is out of date.

Short answer

BS 6229:2025 applies now. BSI lists BS 6229:2018 as withdrawn on 16 December 2025 and the 2025 edition as current. Its scope is flat roofs, and curved ones pitched at 10 degrees or less, where the waterproofing is a flexible covering supported along its whole length. Lead is not included. NFRC reports that the 2025 edition asks for a 1:80 finished fall as the minimum, across the roof and in internal gutters.

Two editions and their status

The standard has been revised, and old paperwork still refers to the earlier edition. The status of each, as BSI lists it, is short.

Status of the two editions of BS 6229
EditionStatus
BS 6229:2018Withdrawn on 16 December 2025
BS 6229:2025Current

A withdrawn standard is not wrong throughout, but it is no longer the one that is maintained. A quote, a drawing or a specification that names the 2018 edition was written before the change or without checking it, and the sensible step is to ask for the 2025 text to be named instead. Our own specifications name the edition in plain words, so there is no doubt about which text was meant.

We name the current edition in our own write-ups, and we date each survey so that a later reader knows what the roof looked like on the day. Where an existing roof was built to the 2018 text, that is simply its history, and the survey records what the roof measures today whichever edition it was designed to.

What the standard covers and what it leaves out

BS 6229 is a code of practice for flat roofs, and its scope is specific. BSI describes it as applying to flat roofs, or curved ones with a pitch not greater than 10 degrees, using continuously supported flexible waterproof coverings. For a homeowner, that points to sheets laid across a deck: torch-on felt and single-ply rubber, for example, with the manufacturer's data sheet telling you whether a particular system counts.

Two limits matter to a homeowner:

  • Lead roofs are outside it. Approved Document C cites BS 6915 for lead, so a lead flat roof or a lead-lined gutter follows a different document.
  • Pitched roofs of tile and slate are outside it. They follow other standards, such as BS 5534 for the fixing of tiles and slates, which has its own history and its own page of advice.

Within its scope, the headline number is the fall. NFRC says the 2025 edition sets a minimum finished fall of 1:80, and IKO advises designing for 1:40 to achieve it. Our page on what fall a flat roof needs turns those ratios into millimetres.

What to do if your paperwork cites the 2018 edition

The edition question can turn up as a line in a quote or a specification from an earlier job. A calm sequence works best.

  1. Check the date. A roof built before the withdrawal was specified to the text of its day, and that does not make it defective.
  2. Ask any new contractor to name BS 6229:2025 in the specification for new work.
  3. Ask what finished fall the roof will have, in millimetres per metre, to set against the minimum.
  4. Keep the survey photographs, since they show the deck, the upstands and the outlets as they were on the day, and they are useful if a question arises later.

An edition is a reference point and not a verdict. Our survey of an older roof looks at the fall, the outlets and the covering, and it reports what is there. If the roof ponds, the reason is a measurable one, and ponding water explains how we trace it. To know whether a roof is sound, look at the roof itself, not at the cover page of a standard.

Standards, Building Regulations and the border

A British Standard is issued once for Great Britain, so BS 6229:2025 reads identically on both sides of the border. The Building Regulations beside it do not. In England, Approved Document L (2021 edition) applies until 24 March 2027, when AD L 2026 takes effect. In Wales, the Welsh Approved Document L (2022 edition) applies until its successor takes effect on 4 March 2027.

That gives the answer to the question in the title in two parts. The standard that applies now is BS 6229:2025. The Part L edition that applies now is still the earlier one on each side of the border. A document does not apply simply because it has been published; its start date decides.

For a particular roof, we ask the council's building control service, or a registered building control approver, which documents govern the work, because the edition of Part L that applies depends on the start date of the job as well as the address. Our flat roofing hub links to the guides on membranes, falls and insulation, and the new membrane renovation page covers the energy side.

Related questions

Is a roof built to the 2018 edition now non-compliant?

Nothing in the BSI listing says so. The 2018 edition was withdrawn on 16 December 2025, which means it is no longer the maintained text for new work. A roof built to it is judged on its condition and its fall today. We measure and photograph both, then tell you whether anything needs correcting.

Does the standard apply to my lead-lined box gutter?

No. BS 6229:2025 deals with flexible waterproof membranes, and lead is outside it. Approved Document C cites BS 6915 for lead. Our lead survey looks at the code of the sheet, the laps and the fall of the gutter, and we explain the findings with photographs rather than quoting a standard that does not cover it.

Get your free roof quote

Tell us about the roof and we will arrange a survey.

10-year workmanship guarantee, in writing