A conservatory can be described as exempt, as though that settled everything. The word is shorter than the truth. Under Approved Document L in England, a conservatory can be treated differently from an extension if a list of conditions all hold, and the moment one stops holding, the exemption goes with it. The point tends to surface when someone brings in a heater, knocks through to the kitchen or orders a new roof.
That is why the question is worth settling before work starts and not after. Approved Document L, volume 1, in its 2021 edition with the 2023 amendments, takes effect on 15 June 2022 for use in England, and paragraph 0.14 is where the conditions are listed. The text sets them together, and each one has to be true of your building.
The sections below take the conditions one at a time, explain what a surveyor looks for under each, and then turn to the question that brings readers here: what happens when the roof is replaced. To compare the other roof options, see our conservatory roofs page.
What the exemption is, and what it is not
Exemptions sit in Schedule 2 to the Building Regulations 2010, which lists buildings and work that are exempt from the regulations, and Approved Document L describes how the conservatory case applies to energy efficiency. In plain terms, a conservatory that meets every condition is not held to the same insulation and heat-loss figures as a heated extension. It is treated as a space attached to the house but not part of its heated envelope.
It is not a free pass for everything. Three limits are worth holding in mind:
- The conditions are cumulative. Meet four and miss the fifth, and you are outside the exemption.
- The exemption describes the building as it is. Changing the building, whether by adding heating, removing a separating wall or enlarging the room, can change the answer.
- Other parts of the regulations are separate questions. Structural safety, drainage and electrical work are not switched off by an energy exemption, and a new roof still has to be safe and sound.
We cannot tell from a distance whether a particular conservatory is exempt, and a photograph from the garden will not show the floor area or the heating pipes. We can lay out what the conditions say, measure what needs measuring and flag the points to take to building control, which is the body that decides. Where a conservatory is not exempt, the usual Part L figures apply: a new roof reaches 0.15 under AD L 2021 Table 4.2, roof windows 1.4 or WER Band B, and rooflights 2.2. A supplier's quote should say whether it means a roof window or a rooflight, because their targets differ.
The five conditions at a glance
Paragraph 0.14 of Approved Document L gathers the conditions in one place, and every one of them has to hold. The table puts each in plain English and says what we check at survey.
| Condition | In plain terms | What we check |
|---|---|---|
| Ground level | The conservatory is built at ground level | Floor height and any raised deck |
| Floor area | The floor area does not exceed 30m2 | A measured plan of the room |
| Glazing | The glazing is to Part K | Safety marks on low and door-side glass |
| Separation | The dividing wall, door or window remains, or was removed and has been replaced in some form | Whether the opening still has a closing element |
| Heating | The house's heating is not carried into the conservatory or porch | Radiators, pipes and underfloor heating |
Notice what the list does not contain, because owners sometimes assume otherwise. It names no roof material, no age and no frame type. It does not mention the roof material, the age of the conservatory or whether the frame is aluminium, timber or uPVC. A conservatory with a glazed roof and one with a solid roof are judged on the same five points. A change from glass to tile touches none of them directly, which is why a roof change is not automatically fatal to the exemption but does give building control something new to look at.
Ground level and the 30m2 limit
The first two conditions are about size and position. Condition one: the conservatory floor sits at ground level, and the floor area does not go over 30m2. Neither sounds difficult, but both can go wrong without the owner noticing.
Ground level matters where a house stands on a slope or a raised plot. A conservatory built off a raised patio, a terrace or a sloping garden may sit above the ground at one end, and the question becomes what counts as ground level for the building as a whole. If your conservatory has steps up from the garden or a deck around it, say so at survey, and take the point to building control.
The area limit is a plain number, but the way it is measured can change the result. A room that looks like 28m2 on a brochure plan may measure differently once the walls, a bay or a built-in porch are included, and an extension to the conservatory over the years can push it over. Ask how building control measures floor area, then measure to that rule and write the result down.
If the room is close to the limit, treat it with care. Even a small addition, such as a lean-to for storage, can tip the total over 30m2, and an old plan may no longer match the building. We measure the room on site and put the figure in the survey notes, so the number is on record before ordering. Our guide to the 30 m² limit deals with measuring in more detail.
Keeping the house and the conservatory separate
The separation condition asks that the wall, door or window between the dwelling and the conservatory be kept, and that anything taken out be replaced. The idea is that the conservatory stays a distinct space that can be closed off, so the house keeps its own thermal boundary.
The condition is tested by the way people use the room. A conservatory that is used as an eating area, a playroom or an office can lead to an open doorway, and a patio door taken out to widen the opening is the most direct way of removing the separation. If the doors between house and conservatory were removed some time ago, the condition may already have failed. It can be restored by fitting a replacement door or window, but the work needs to be done and recorded.
Points to establish before a roof job:
- whether the original wall, door or window remains between house and conservatory
- if it was removed, whether anything replaced it, and when
- whether the replacement can be closed and is part of the building, not a curtain or a screen
- whether there are plans to open the room up in future
A roof that is renewed with the intention of opening the room into the house should be designed as part of the house, with the roof, walls and floor all meeting the full figures. Our guide on what to do if the doors between house and conservatory were removed sets out the options.
Heating and glazing: the other two conditions
Two conditions remain. The first is the one that owners can break without noticing. Approved Document L expects the dwelling's heating system to stay out of the conservatory and the porch. The wording is about the dwelling's system, so radiators on the house circuit, pipes run into the room or underfloor heating connected to the boiler would all extend it.
We do not turn this into a rule about every kind of heater, because we do not know from this wording how every portable or separate source would be treated. If you want to warm the room, ask building control first. It is far easier to adjust a plan than to unpick an installed system, and a short note from building control before the work is worth having on file when the house is sold.
The second is the glazing condition: the glazing must comply with Part K. Part K of the Building Regulations covers protection from falling, collision and impact, and for glazing it deals with panes that people could walk into or fall against, such as large low panels and glass beside doors. Older roofs and side panels are the ones to look at closely, since their glass may predate the marks.
A surveyor will look for the safety marks etched in the corner of the glass, check the lower panels and the glazed doors, and note any pane that has been replaced with something of unknown origin. Our guide on heating a conservatory and keeping it exempt follows the heating question through in detail.
Changing the roof of an exempt conservatory
This is the question that matters most to a roofer. On conservatory roofs, the Planning Portal says a new roof has to comply with the building regulations so that it is safe, efficient and properly ventilated, and its guidance does not carve out an exempt conservatory. So the sensible route is to put the proposed roof to building control before ordering, whether the conservatory looks exempt or not.
Regulation 2 of the Building Regulations 2010 explains why the roof is treated seriously. A thermal element means a wall, floor or roof, and the regulation excludes glazed parts such as roof-lights. A replacement roof is therefore a thermal element, even when its glazing is not. Where the conservatory is not exempt, the new roof is held to these Part L figures for England: 0.15 for the roof, and 1.4 or WER Band B for any roof window.
The timing matters too. AD L 2026 takes effect on 24 March 2027 for use in England for building work that is not in connection with higher-risk building work, and its tables are renumbered 3.2 and 3.3. A job that starts before that date follows the edition in force, and one that starts after follows the new one.
Building control is carried out by the council or by a registered building control approver. In Herefordshire, Herefordshire Council Building Control is on 01432 261938. We supply the roof make-up, the structural check and photos of the existing conservatory, so the question reaches building control with the facts attached. Our written quote is a single price that follows the survey, with scaffold named in it.