In brief
The England test in Approved Document L, paragraph 0.14, is that the floor area "does not exceed 30m2". Measure the floor, write the figure down, and ask building control how they measure it. A room of 5 m by 6 m just meets the limit, and a larger floor is outside it. Passing on size does not make a conservatory exempt, because four other conditions apply as well. In Wales, ask the council's building control service or a registered building control approver which figure the Welsh document sets.
Floor area, not roof area
The sentence in the England document is about the floor: the floor area "does not exceed 30m2". A big glass roof, a heavy tiled one or a deep overhang changes how the room looks, but none of them changes the floor. So swapping the roof does not move you across the limit. Building a larger base would.
A few plain examples show how quickly the floor figure grows as the room gets longer:
| Floor, length by width | Floor area | Against 30m2 |
|---|---|---|
| 4 m by 3 m | 12 m2 | Well inside |
| 5 m by 5 m | 25 m2 | Inside |
| 5 m by 6 m | 30 m2 | Just meets it |
| 6 m by 6 m | 36 m2 | Over |
Adding a metre to each side of a 5 m square takes it from 25 m2 to 36 m2, which is the sort of change that surprises owners planning an extension. If your room sits close to 30, treat the measuring as the job and not the sum. A glazed bay or porch built on to the room belongs in the total when it shares the same floor.
Working out your own figure
The Approved Document gives the limit, and building control decides how a particular floor is measured, so take the measurements and show them. A fair way to gather them:
- Measure the length and width of the floor inside the room, at floor level.
- For an L-shaped or angled room, split it into rectangles and add the areas.
- Photograph the tape on the floor at each end, so the figure can be shown.
- Measure twice if the answer lands within a hand-span of 30.
- Keep the drawing with the house papers for a future sale.
When we survey for a new roof, we measure the room as part of the visit and photograph the walls and the junction with the house. That survey is no substitute for building control, but it gives them numbers rather than an estimate.
Floor area is the one condition you can check with a tape in ten minutes. The other four need photographs and, in some cases, a conversation with the council, so do the measuring first and find out early whether the rest is worth pursuing.
If the floor comes out over 30
A floor over the limit cannot meet the size condition, so no exemption is available. The roof is then treated as a new roof added to an existing house, and the figures differ either side of the border:
- England, Table 4.2 of Approved Document L 2021: roof 0.15 W/(m2.K); roof windows 1.4 or Window Energy Rating Band B; rooflights 2.2 (both countries use the same window and rooflight figures).
- Wales, Table 4.1 of the Welsh Approved Document L: roof 0.13; roof windows 1.4 or WER Band B; rooflights 2.2.
The Planning Portal adds a general line for England: a replacement conservatory roof has to be safe in structure, efficient with energy and ventilated, and that is the test building control applies. In England AD L 2026 renumbers these as Tables 3.2 and 3.3 from 24 March 2027. In Wales the replacement document starts on 4 March 2027. Check which edition is in force when your work is done, because the tables are read from the edition that applies on the day.
A roof built to those figures is an insulated roof, so our page on whether insulated roof panels work shows how one is judged.
The four conditions that sit beside size
Size alone never makes a conservatory exempt. In England the same paragraph also asks for a floor at ground level, glazing that meets Part K, the divide with the house kept or put back, and the house heating kept out of the room. A conservatory can pass on 24 m2 and still fail on any of the others.
Two of those have their own pages, and each one sets out what to ask. Removed doors between house and conservatory and heating the room are the two limbs a later change to the house side can break, so read both before altering it.
For Wales, the Welsh Approved Document L words the size limb differently: an internal floor area "less than 30 m2" (paragraph 0.16). In Monmouthshire, Powys and the Bannau Brycheiniog National Park, the council's building control service or a registered building control approver can say which figure and which conditions the Welsh document sets. The conservatory roofs hub lists the other questions to put to them. Whatever the answer, keep the measured drawing: a buyer's solicitor may ask for it, and it saves measuring the room twice.