01432 610152 Get a quote Call 01432 610152

Drainage and lead

Gutters and lead flashings on conservatories

Whether a conservatory stays dry depends on the gutter beneath the roof and the lead above it. This guide covers how both work, how they fail and what a replacement involves.

Horizon Roofing Hereford 9 min read

Gutters and lead are the quiet parts of a conservatory roof. Nobody chooses a conservatory for them, and nobody looks at them until a wall is stained or a pane drips. Yet between them they carry the rain off the roof and seal the one joint that has to work against the house. When either fails, the glazing or sheet gets the blame for a fault that began somewhere else.

This guide takes the two in turn. The gutter side covers where the water goes, the fall a run needs, the materials on offer and what the published costs and lifespans look like. The lead side covers where lead sits on a conservatory, which thickness suits which job and when it is renewed. The rules for roof work are labelled England or Wales in each sentence that gives one, since the approval route differs across the border.

The wider service is described on our conservatory roofs page, and the single joint where roof and house wall meet has its own guide on leaks at the house wall.

Where the rain goes when it leaves the roof

A conservatory roof sheds water to one or more edges, and each edge ends in a gutter or in the house's own drainage. On a lean-to the water runs down a single slope into one gutter along the front. On a roof with several facets it runs to the eaves on each side, and the valleys where two facets meet carry it down in a concentrated stream.

That stream is the reason conservatory drainage is more demanding than it looks. The roof is mostly smooth glass or sheet, and it sheds rain quickly, so the gutter has to take a lot of water in a short time. Four things decide whether it copes:

  • the size of the gutter and its outlets, matched to the area of roof that drains into it
  • the fall along each run, so water travels to the outlet rather than standing
  • the downpipe, which has to carry the flow to a drain or soakaway without backing up
  • the condition of the joints, because a joint that weeps sends water round the back of the gutter and down the wall

On some conservatories the roof drains toward the house, not away from it, so the gutter sits against the wall or in a valley with the main roof. Where that happens, the conservatory gutter and the house gutter may share an outlet, and a blockage in one can send water into the other.

A blocked outlet is the quickest way to turn a good gutter into a bad one. Leaves, moss and roof grit settle in the lowest point, and rain that cannot leave the gutter spills over the front or backs up under the roof edge.

Getting the fall right

A gutter that holds water is a gutter set flat. The gutter manufacturer Brett Martin states the fall as "1mm for every 600mm" along the run, falling towards the outlet. That is a gentle slope, close to flat to the eye, and it is easy to lose when brackets are fixed by feel.

What that fall means along a run
Length of runDrop towards the outlet
1.8 m3 mm
3.0 m5 mm
6.0 m10 mm

The figures are Brett Martin's ratio worked through for three lengths. They show how little height is involved, and why a gutter fixed to a fascia that has sagged, or to brackets that have bent, can hold a pool instead of draining.

The same ratio holds for the gutter on the house side, so a gutter bracketed to a sagging fascia needs the board put right first.

Standing water has consequences beyond overflow. It adds weight to the brackets and the fascia, it carries silt that settles in the low spot, and in cold weather it freezes and splits joints. Standing water a week after the last rain means the run has lost its fall.

When we survey a conservatory we lay a spirit level along every run and note any that hold water. The finding is photographed, and the fix is stated in the written quote, whether that is refixing brackets, renewing a run or correcting the fascia the gutter is fixed to.

Gutter materials, lifespans and published costs

Plastic guttering is the kind the published figures cover, and uPVC is the material they name. The costs and lifespans below are typical UK ranges from third parties, never our prices.

  • MyJobQuote's page on gutter replacement gives an average of around £1,000 to £1,600 for a UK job, and around £40 to £50 per metre for standard uPVC.
  • On MyJobQuote's figures, capping fascias and soffits comes to around £800.
  • Which? (November 2025 survey, ex VAT) prices a full gutter clear-out, front and back of a house, at £75 to £350.
  • A retailer of uPVC fascias, an interested party, puts their typical dependable working life at between 20 and 40 years.

The first two figures describe a whole house, not a conservatory alone, so a conservatory run cannot be read off them. The per-metre figure is a unit rate, and it is not turned into a total here, because the length, the fittings and the access change the sum.

Gutter colour and profile matter less than the joints. A square profile and a half-round profile both work when the fall is right, and both fail when it is not.

Lifespan is as much about the fascia and brackets as about the gutter. A good gutter on a rotten fascia board will not hold its fall for long. Where the fascia is timber, the survey looks at it for softness, and where it is already capped, we look for gaps where water can get behind.

Whichever material is chosen, the written quote gives one total price and says whether the downpipes, the fascia work and the VAT are in it.

Where lead sits on a conservatory

Lead is the traditional answer for the places where a roof meets something it cannot overlap. On a conservatory that means three jobs, each with its own name in the lead trade.

  • The abutment flashing, a strip turned up the house wall and over the roof edge, sealing the long joint with the house.
  • Soakers, small folded pieces under tiles or slates, which carry water clear at the roof's edge where it runs against a wall.
  • Valley gutters, where two facets of a multi-faceted roof meet and the lead lines the channel between them.

In Royston Lead's table, each code is assigned to jobs by letter. Soakers are the use letter A, flashings are B, pitched valley gutters are C, parapet and box gutters are D, and dormers are E.

Lead codes against use, from Royston Lead
CodeThicknessUsed for
31.32 mmA: "Recommended for lead soakers only"
41.80 mmA, B, C, E
52.24 mmB, C, D, E
62.65 mmB, C, D, E

The length of a run and its exposure decide the code, and we choose at the survey. A short soaker under a tile can be a lighter code than the flashing that covers it, which is why one house can carry more than one thickness.

Lead is soft, so it is also dressed to the shape of what it covers. Its edges are folded, its joints are lapped and its fixings are set so it can move without tearing. The craft is in those details more than in the sheet itself.

Lead costs, lifespan and when to renew

These figures come from MyJobQuote's page on chimney leadwork, so they give an indication of scale and not a quote for a conservatory. A chimney lead flashing patch repair is around £200, and a full replacement averages around £570. Full leadwork is £350 to £920, and the need for scaffold shapes where a job falls in that spread. A conservatory sits lower than a chimney and is reachable from a low tower, which is one reason to treat the chimney figures as an upper guide only.

On lifespan, the sources give a range:

  • MyJobQuote's line is that a lead flashing fitted correctly "can last for over 80 years".
  • HomeBuilding and Less publish longer ranges, but theirs are for lead flat roofs, a different job from a conservatory flashing.

No single conservatory flashing is guaranteed by these ranges. The lead itself may outlast its fixings, and what gives out can be the pointing, the wedges or the sealant.

A lead flashing that is sound but loose can be re-wedged and re-pointed, which is a smaller job than renewing it. That is what the survey is for: to say whether the lead is the problem or the fixing is.

The best moment to renew lead is when the roof covering is renewed, because the old flashing has to come off to free the bars anyway. A new roof under an old flashing leaves the oldest part of the job in place. When a roof is replaced, we assess the lead at the same visit and say whether it can stay or should be renewed. Either way it is shown in photographs, and the decision is yours.

Our walkthrough of a replacement, conservatory roof replacement, day by day, shows where the lead and gutters come in.

The rules, and what a survey checks

Replacing a run of gutter or re-dressing a flashing is maintenance, and it does not by itself bring in the approval rules for a new roof. The rules matter when the work grows into a new covering.

  • In England, the Planning Portal puts a new conservatory roof under the Building Regulations.
  • In Wales, the Welsh Government says of re-roofing: "In most situations, this work will need Building Regulations approval."

If a gutter run is being renewed with a new roof, building control is asked about the whole job first. In England, Herefordshire Council Building Control is on 01432 261938 for Herefordshire addresses, and on either side of the border a registered building control approver is the private alternative.

Drainage and lead repay a regular look, because they sit where weather concentrates. A look every year, from the ground and from inside, catches a blocked outlet or a lifting flashing before it becomes a stain. Clearing gutters, where it is safe to do so from a stable ladder, and checking the downpipe discharges clear of the wall, are two small jobs that protect the wall and the frame.

On the survey we check:

  1. the fall of each run, by eye and by level
  2. the joints, outlets and downpipes, for leaks and blockages
  3. the fascia the gutter hangs from
  4. the lead at the wall, including the pointing and the lap over the roof edge
  5. the ground below, where a downpipe discharges

You see the photographs, and the agreed work is quoted as one total in writing.

Gutter and lead questions

How steep does a conservatory gutter need to be?

Brett Martin gives the fall as 1mm for every 600mm towards the outlet, which is 5 mm over a 3 m run. That is almost flat to the eye, so it is checked with a level on site. A run that still holds a pool after the rain has stopped has lost its fall and needs refixing.

Is lead needed where the conservatory meets the house?

Lead is the traditional material for that joint, with the flashing at Code 4, 5 or 6, the codes Royston Lead's table lists for flashings. Other flashing materials exist, and the survey looks at what is fitted before suggesting a change. Whatever the material, the joint has to take movement between the two structures.

Do I need approval to replace gutters on a conservatory?

Gutters alone are maintenance. If a new roof goes on, the Planning Portal puts a new conservatory roof under the Building Regulations in England, and in Wales the Welsh Government's re-roofing page expects Building Regulations approval in most situations. Building control is asked about the whole job before the work starts.

Get your free roof quote

Tell us about the roof and we will arrange a survey.

10-year workmanship guarantee, in writing