01432 610152 Get a quote Call 01432 610152

Stack tops

Flaunching on top of the stack: what it does and why it cracks

A lump of mortar round the pot bases is small, high up and easy to ignore. This guide explains what it does, why it cracks and what a proper renewal involves.

Horizon Roofing Hereford 9 min read

Look up at a chimney stack from the garden and the last thing you see is a sloping cap of mortar with the pots rising out of it. That cap is the flaunching. It sits on the top course of the shaft, grips the base of each pot and carries rain away from the flue openings and out over the edge of the stack. When it is sound nobody notices it. When it cracks or crumbles, the stack top takes in water, the pots loosen and the damp starts working down the shaft.

Flaunching is the top layer of a stack that takes the full weather, and it is a smaller job to put right than a shaft that has soaked through several winters. That is why we check it early on every chimney survey.

The sections below explain what the collar is made of and what it does, why it fails, how to read the signs from the ground and the loft, how it is renewed, what to expect on cost, and the points of law on each side of the border. Our chimney repairs page sets the job in the context of the whole stack.

The parts at the top of the stack

Terms get muddled at the top of a chimney, so it helps to set them out in order from the pot downwards. A stack has more layers than it appears to from the street, and each has its own failure.

The top of a chimney stack, from the pot down
PartWhat it isWhat it does
PotA clay or concrete tube set on the stackExtends the flue and shelters its mouth
FlaunchingA sloped mortar collar round the pot baseHolds the pot and sheds rain
Top courseThe last layer of brick or stoneCarries the collar and the weight of the pots
ShaftThe brick or stone body of the stackCarries the flue above the roof
FlashingLead where the shaft meets the slopeSeals the joint with the roof covering

On a stone stack the same layers apply, only the top course is dressed stone. A sandstone top course takes mortar differently from a fired brick, which is one reason the repair has to be matched to the stack rather than copied from another one. Mortar that suits a soft old stone is not the mortar for a hard engineering brick, and the choice is made at the survey, with the top course in view.

Of the five, the mortar cap meets rain and frost most directly, which is why it is the layer that gets redone while the pot and the shaft carry on beneath it.

What the collar does for the pot

Flaunching has three jobs, and a crack that defeats any one of them is enough to cause a problem.

The first is to hold the pot: a clay pot is set on the top course and bedded in mortar, and the collar stops it rocking in a gust. A pot that moves in the wind works the mortar looser, which lets more rain in, which loosens it further. The second job is to shed water. The surface is made to slope away from the pot on every side so that rain runs off over the edge of the stack instead of lying around the base. A flat or dished collar holds a film of water against the pot and the top course, and that is where frost does its work.

The third is to seal the gap between the pot and the stack. Where a flue has no pot, or the pot sits on a bedding of mortar, the collar closes off the joint so that rain does not run down the inside face of the shaft.

A well-made collar therefore has a few features you can look for from a distance:

  • a smooth, sloped surface falling away from each pot
  • an edge that overhangs the top course a little, so that drips fall clear of the brickwork
  • no gap between the collar and the pot, and no open joint along the underside
  • a firm bond to the top course, with no hollow sound when it is tapped on the roof

None of this needs scaffolding to see: binoculars from the garden show most of it.

Why flaunching cracks

Mortar is a hard, brittle material, and a stack top gives it a rough life. Nothing shelters it from above, and it takes sun on one face while another stays wet and cold. The reasons it cracks are well understood.

  • Movement: the pot, the collar and the top course expand and contract at different rates through the seasons, and the collar splits where the pull is greatest.
  • Frost: water gets into a hairline crack, freezes and widens it, then drains out and leaves a bigger gap for the next rain.
  • A mix that is wrong for the job: mortar that is stronger than the brick beneath it can pull away from the top course instead of moving with it, while a very weak mix wears away.
  • Shape: a collar made too thin at the edges breaks off, and one made without a fall holds water.
  • Drying too fast: a new collar put on in hot sun or wind can cure unevenly and crack in its first season.
  • Pot movement: a rocking pot, loosened by wind, breaks the bond all round its base.

A repair that deals only with the cracks, filling them with a thin skim, can fail again because the cause has not been addressed. A hairline crack may be sealed or filled. A collar that has lifted, sounds hollow or has lost its edges is better renewed than patched.

Reading the signs from the ground and the loft

You can learn a good deal about a stack top without leaving the ground, and the loft adds more. Do not climb onto the roof to look: a stack top is a poor place to find out that a pot is loose.

From the garden, with binoculars if you have them, look for:

  • mortar lying in the gutter, on a flat roof or in the flower bed beneath the stack
  • a pot that leans, or sits at a different angle from its neighbour
  • dark or green staining on the top few courses, where water has been lying
  • a gap you can see daylight through between the pot and the collar
  • vegetation rooted in the cap, such as moss or a seedling

In the loft, the flue passes close to the roof timbers and the breast can be visible. Damp on the chimney breast, a stain that spreads upward from the rafter line, or a tide mark on the brickwork beside the stack can all point to water entering at the top. Because water runs down and sideways before it shows, the mark can be some way below the fault. Our guide to chimney flashing leaks explains how to tell a failed collar from failed lead, since the two sit close together and cause the same stains.

If you see a pot that has slipped, or loose masonry hanging over the roof, keep clear of the ground below and call us. Photographs of the stack top, taken on your own roof, are shown to you before anything is agreed.

How flaunching is renewed

Renewing a collar is a short job on the roof when the stack is sound underneath, and the order of work is what makes it last.

  1. Access: a scaffold or tower gives a safe working platform at the stack top, and if it must stand on the public highway, the licence is something we sort out with our scaffolder.
  2. Photographs: the old collar, the pots and the top course are photographed before anything is touched.
  3. Pots: each pot is lifted off and checked for cracks, then set aside to be re-bedded or replaced.
  4. Old mortar: loose and hollow collar is chipped away back to firm material, and the top course is cleaned of dust and debris.
  5. Top course: any loose or frost-damaged brick or stone is repointed or replaced, because a new collar cannot hold on a failing base.
  6. New collar: a mortar matched to the stack is laid with a firm fall from each pot to the edge, an overhanging lip and a smooth finish.
  7. Pots reset: each pot is bedded plumb into fresh mortar and the join sealed.
  8. Curing: the new work is protected from fast drying while it hardens.

The mortar choice matters. A lime mix moves more readily with an older stack, while a cement mix is harder. Which suits your stack depends on what is beneath it, and our answer to lime or cement mortar on a chimney sets out the reasoning. We look at the lead flashing at the base of the shaft on the same trip, since renewing the top of a stack that leaks at the bottom achieves little.

The old mortar and debris go away with us at the end of the visit.

Nests, pots, planning and what it costs

Two points come before the work. Birds nest in pots and on stack tops, and bats use some roofs. Nests that are occupied, or still under construction, are protected, and a nest is protected once birds start building it, and under section 1 of the Wildlife and Countryside Act 1981 anyone who "intentionally" harms it commits an offence while the nest remains in use. Bats and their roosts have protection of their own, with licences from Natural England for a site in England and from Natural Resources Wales for one in Wales. If we find either at the pots, we stop and explain the options.

On the rules about the stack itself:

  • In England, Class C of the 2015 Order covers alterations to a roof, but condition C.1(d)(i) excludes "the installation, alteration or replacement of a chimney, flue or soil and vent pipe".
  • In Wales, the 1995 Order's Class C.1(c)(i) has the same exclusion, worded "the installation, alteration or replacement of a chimney".
  • On a shared stack in England or Wales, the Party Wall etc. Act 1996 may apply; our guide to chimneys on a party wall sets out the notice periods.

Putting a new cap on the stack is a repair. If the job grows into altering or replacing the chimney, ask the council before work starts. Listed houses need their own consent too: listed building consent under section 7 of the 1990 Act in England, or authorisation under section 88 of the Historic Environment (Wales) Act 2023 in Wales.

For cost, the survey comes first and a written total follows it. What sets it is the height and access, the number of pots, the state of the top course and whether lead needs attention. For context, MyJobQuote (page dated 22 September 2026) gives around £200 for patching the lead flashing on a chimney and around £570 for a full replacement.

Stack tops: your questions

Can a cracked collar be filled instead of renewed?

A hairline crack can sometimes be sealed, but a collar that has lifted, sounds hollow or has lost its edges is better renewed. Filling over a failing bond holds water against the top course and the crack can return. We photograph the cap and show you which case you have.

Does a new collar mean taking the pots off?

Yes. The pots are lifted, checked and re-bedded in the new mortar so that each one sits plumb with a sloped collar round its base. A cracked pot is replaced at the same visit. Where a nest or bats are present, we pause and explain the legal position first.

Is reflaunching a job that needs planning permission?

A fresh cap is a repair. Both Orders exclude altering or replacing a chimney from Class C: England at C.1(d)(i), Wales at C.1(c)(i). If the work grows beyond the cap, ask the council. A listed house needs listed building consent in either country.

Get your free roof quote

Tell us about the roof and we will arrange a survey.

10-year workmanship guarantee, in writing