Callout 1 of 3
Eaves, underlay and air in the roof
Underneath the slates or tiles lies a membrane, and under that a roof space whose air has to go somewhere. Condensation is the usual reason a roof space goes wrong, and BS 5250 is the code of practice on it. BSI lists the standard as current but under review, and Approved Document C of 2013 points to the older 2002 edition in its own paragraph 6.10. Whatever edition is cited, the lesson on a Pensax roof is the same: insulation or a membrane that blocks the route out of the roof space can cause more damage than the weather.
Two families of underlay behave differently. A high-resistance (HR) sheet stops vapour passing, so for a cold roof Marley asks for a continuous eaves opening of 25mm at pitches of 15° or less and 10mm above 15°. An air-permeable (LR) sheet over a ceiling that is properly sealed can manage with ordinary eaves construction at 3mm, once its UKAS third-party certification is satisfied in full. We read the label on the roll in the loft, not the brochure, because the sheet that is actually up there decides what the eaves need.
Spray foam sprayed to the underside of the roof changes the picture again. As the Energy Saving Trust puts it, closed-cell foam is "not vapour permeable", open-cell is "the more vapour permeable", and the rot "risk should be much lower" with an open-cell foam. Where foam has been fitted, the survey checks the rafter feet and the battens, because that is where damp collects out of sight.
From inside the loft we search for daylight, damp patches on the boarding and nails with orange tips. Outside, a few slates come up near the gutter so that we can photograph the lower edge of the underlay, the gap behind the fascia and the end of the insulation, which has to stop short of that gap. Torn underlay can be relaid in sections whenever the battens beneath it are sound, and the gap that results is closed with the lower courses refixed. Those figures are written for a cold roof, with insulation laid at ceiling level so that the rafters stay cold, and the first thing we note is which kind of roof you have. Our roof inspections page shows what each survey covers.
Under the covering, at a Pensax eaves line
- Underlay label read, HR or air-permeable
- Eaves gap clear of insulation
- Torn or slipped underlay at the lower edge
- Batten ends and fascia back free of rot
- Rafter feet dry beneath any foam
Nobody sees the underlay, but the whole roof space depends on what it lets through.