01432 610152 Get a quote Call 01432 610152

Roofers in Pencombe

Roof repairs and re-roofs for Pencombe, 13 road miles north-east of Hereford.

A written price follows once the roof has been read as a whole, from the verge up to the chimney lead.

Get a free quoteCall 01432 610152

Small parish, old frames, three Grade II listings

  • Older cottages with weathered clay tile roofs and brick chimneys behind a flint wall
    Frames from the 1600sThe Royal Commission found two-storey timber-framed houses here, covered in tile or slate.
  • Slate roofs and chimney stacks along a red brick Victorian terrace
    Three Grade II listingsThe church, The White House and Tally Ho each need consent for roof work.
  • Newer homes with grey concrete tile roofs along a curving estate road
    Stacks and their leadEvery stack on an old house has lead that needs checking at survey.

Where to find Pencombe

Pencombe on a street map, with a dashed circle around the town and the nearest towns we cover. Tiles © Esri; map data © Esri, HERE, Garmin, OpenStreetMap contributors.

Pencombe's roofs, frame to gutter

A Pencombe roof from the timber frame down to the gutter line

The Pencombe survey follows three callouts: the timber frame of the 1600s with its tile or slate cover, the stacks and lead on listed houses, and the eaves where rainwater leaves the roof.

A drawn cut-away section through a Herefordshire border house: the front of the main roof is cut open to show the rafters, underlay, battens and slates, beside a black-and-white timber-framed gable. Numbered, from the ridge down: 1 Frame and covering; 2 Stacks and lead; 3 Eaves and gutters.

Fig. 1 A border house cut open, with its frame, stack and eaves numbered for Pencombe.

Callout 1 of 3

Seventeenth-century frames under tile or slate

We begin with the oak and its covering, because the Royal Commission's 1932 volume on Herefordshire starts there for Pencombe. It describes the buildings numbered 4 to 15 (apart from any it singles out) as "of the 17th century and of two storeys" and as "timber-framed and with tile or slate-covered roofs". That is a statement about those monuments in 1932, not a head count of today's roofs, and we never guess a covering from the village. We look.

Tile or slate, the covering hangs from battens fixed across the rafters, and an underlay lies beneath it. If the underlay is high resistance (HR), which does not let vapour through, Marley's ventilation guidance asks for a 25mm gap along the eaves on pitches of 15 degrees or less, and 10mm on steeper ones. Where the underlay is air-permeable (LR) and the ceiling underneath is well sealed, Marley treats the small gap left by normal eaves construction as enough, so long as the conditions of its UKAS certification are met in full. Old timbers dislike trapped damp, so on a frame this small detail gets measured and photographed.

On lifespans, Marley says the BRE's 60 years as a minimum life expectancy is a clay tile figure only. HomeBuilding gives clay tiles "60-80 years". For concrete the sources part company: Marley expects tiles "to last for around 60 years", while HomeBuilding puts plain concrete tiles at "40-50 years". We name both, since they come from two different sources, and neither tells you what your own roof will do.

Weight is the other thing a frame cares about. AD A, paragraph 4.4, says: "A significant change in roof loading is when the loading upon the roof is increased by more than 15%." A swap from clay to a heavier covering can cross that line, which means Building Regulations approval, and before anything is ordered the rafters and wall plate need a structural check.

At the survey we open the covering at one sound place, photograph the battens and underlay beneath it, and walk the verge where the covering meets the gable timbers. You receive the pictures with the findings, and the written total follows. Our pitched roofing page lists the coverings we fix and replace.

Under a Pencombe covering

Battens
Spacing and condition along every course
Underlay
HR or air-permeable, and the state of its laps
Eaves gap
25mm to 15 degrees, 10mm above, with HR underlay
Verge
Bedding and edge units where roof meets gable
Frame
Any gap between the timbers and the covering

On a frame that has been shifting since the 1600s, verge and covering are read together.

Fig. 2 Timber frames, drawn close

Callout 2 of 3

Listed houses, their stacks and the lead round them

Next comes the chimney, which rises alone above the slopes and takes the weather on every side. Three buildings in the Pencombe record are listed Grade II: the Church of St John (list entry 1276162), The White House (list entry 1276190) and Tally Ho (list entry 1234314). All three were first listed on 12 April 1973. A listing takes in the whole building, chimney included, so a stack is never a free-standing repair.

Where work changes a listed building's character, section 7 of the Planning (Listed Buildings and Conservation Areas) Act 1990 calls for listed building consent. We raise that with Herefordshire Council before a stack is rebuilt or its lead is renewed. For anything involving a new roof window, our planning guide carries the conditions in full.

Lead is what seals the joint between stack and slope. Royston Lead's table gives each code its jobs. Code 3 is "Recommended for lead soakers only", and a soaker is the small folded sheet tucked under each course beside a stack. Code 4 is rated for dormers, pitched valley gutters, flashings and soakers, and Code 5 adds parapet and box gutters. MyJobQuote's page on leadwork says correctly installed lead flashing "can last for over 80 years". That is a hedge about good fitting, not a lifespan we can promise for yours.

Removing a chimney breast raises other rules. The Planning Portal says: "Building regulations approval will always apply when removing chimney breasts as they are part of the building's structure." A shared breast brings the party wall rules in too: the owner serves notice, and the first cut into a Pencombe breast waits for at least two months after it, and the neighbour's dissent, or 14 days of silence, is what brings a surveyor in. Building control has no say in Pencombe party wall matters, which sit with a party wall surveyor.

Most of the survey at a stack is looking, with a camera. We photograph each flashing, the mortar joints and the pots from the roof, and the report shows where the lead has lifted or split. The cement fillet that holds each pot is checked too, since a cracked fillet lets rain run down inside the stack. Our chimney repairs page covers rebuilding, repointing and relining.

Checked at a Pencombe stack

  • Lead tucked into joints, not just stuck on
  • Mortar joints in the stack itself
  • Pots and the cement fillet around them
  • The lead tray behind the stack
  • Soakers beside the stack, course by course

The lead around a stack is renewed only after we have seen where the old lead has failed.

Fig. 3 Chimneys, drawn close

Callout 3 of 3

The Grade II church and its gutter line

The last callout is the gutter, the eaves channel that carries rainwater off the roof. Brett Martin's guide says to lay a gutter with "1mm for every 600mm" of fall, so a 6 metre run drops 10mm from one end to the other. A gutter that has sagged below that holds water against the masonry and the timber behind it. A retailer of uPVC boards, with something to gain from selling them, says they typically keep performing reliably for between 20 and 40 years.

The Church of St John is Grade II, and a church roof has gutters like any other. Not every church goes to the council. Church of England churches that remain in use come under the faculty jurisdiction, and buildings in use that are Catholic, Methodist or URC are exempt too, each answering to its own body, as are Baptist Union ones a Schedule 1 trust corporation holds. A Unitarian chapel or a Quaker hall sits outside it, as do redundant churches and buildings held by the Churches Conservation Trust: listed building consent applies to those. Ask the church's governing body first, and we will survey whatever it asks us to.

A re-cover in England is measured by the Planning Portal against two limits: under 25 per cent of the building envelope and under 50 per cent of the roof. Keep beneath both limits and no application should normally be needed. The brackets, joints and stop ends along the eaves get the same attention as the boards. Herefordshire Council Building Control, or a registered building control approver, handles anything larger, and the council's email for enquiries is bce@herefordshire.gov.uk.

If the job includes new insulation, AD L 2021 applies until 24 March 2027. Table 4.3 gives a roof threshold of 0.35 and an improved figure of 0.16 W/(m²·K) for renovation, and paragraph 4.13 lets the figure relax where a simple payback of 15 years cannot be reached. Roof windows take 1.4 or WER Band B, and rooflights 2.2. After that date AD L 2026 Tables 3.2 and 3.3 take over.

Herefordshire has 64 conservation areas, and Herefordshire Council keeps the list. Look your house up on that list, and ask the council too whether an Article 4 direction reaches it. Our guttering, soffits and fascias page covers the repair side of the eaves.

Eaves words, explained

Fall
The slope that lets a gutter drain towards its downpipe.
Fascia
The board along the rafter ends that carries the gutter brackets.
Soffit
The board closing the gap under the roof overhang.
Downpipe
The vertical pipe that takes gutter water down to the drain.

Pencombe roofs: frames, listings and lead

Do Pencombe's seventeenth-century houses still wear their original roof coverings?

The Royal Commission's 1932 volume describes the monuments numbered 4 to 15 in Pencombe as 17th-century, two-storey houses, timber-framed, with roofs of tile or slate. That records how they were built, not how old any covering is. Coverings are replaced over the centuries, so the survey reads the battens, underlay and rafters beneath yours, then reports what is original, what is not and what can be reused.

Which buildings in Pencombe are listed, and what difference does that make?

The Church of St John, The White House and Tally Ho are each listed Grade II, first listed on 12 April 1973. Work that affects a listed building's character needs listed building consent under section 7 of the 1990 Act, and the whole building counts, chimney included. Those are three entries; check the National Heritage List for England for your own house before planning any roof work.

How do I check whether my Pencombe house is in a conservation area?

Use Herefordshire Council's own conservation area list, which covers 64 areas across the county, and match it against your address. A second question for the council is whether any Article 4 direction covers the house, because that is how particular permitted development rights get withdrawn. Doing both before the survey saves a second visit later, once the council's view on materials is known and the report can reflect it.

What building rules cover a Pencombe re-roof?

Pencombe is in England, so the Planning Portal sets the line: an application is normally unnecessary below 25 per cent of the building envelope and below 50 per cent of the roof. A covering that is 15 per cent or more heavier needs Building Regulations approval plus a structural check, per the Planning Portal. Herefordshire Council Building Control, or a registered building control approver, handles the paperwork for anything bigger.

Does scaffold on a Pencombe lane need a licence?

It does when the scaffold obstructs a highway, under section 169 of the Highways Act 1980. Herefordshire Council's fee is £167 for a maximum of one month, £123 for each month added, and 10 days or more of notice is needed. We arrange the licence with our scaffolder, and the scaffolding is counted inside the single written total you receive once the survey visit is complete.

What do published prices say for fixing a few tiles?

Which? reported in its November 2025 survey, ex VAT, that one to six tiles cost "£75-£400" to replace and a new ridge tile "£80-£300". These are typical UK ranges from a third party, not our prices. After a Pencombe survey we give one written total, based on what we found on your own roof and photographed for you, and we say plainly when a small repair is the better buy than a new covering.

Book a frame-to-gutter survey in Pencombe

Say what you have noticed on the roof, include a picture if you can, and we will propose a date to survey it.

10-year workmanship guarantee, in writing