Callout 1 of 3
Seventeenth-century frames under tile or slate
We begin with the oak and its covering, because the Royal Commission's 1932 volume on Herefordshire starts there for Pencombe. It describes the buildings numbered 4 to 15 (apart from any it singles out) as "of the 17th century and of two storeys" and as "timber-framed and with tile or slate-covered roofs". That is a statement about those monuments in 1932, not a head count of today's roofs, and we never guess a covering from the village. We look.
Tile or slate, the covering hangs from battens fixed across the rafters, and an underlay lies beneath it. If the underlay is high resistance (HR), which does not let vapour through, Marley's ventilation guidance asks for a 25mm gap along the eaves on pitches of 15 degrees or less, and 10mm on steeper ones. Where the underlay is air-permeable (LR) and the ceiling underneath is well sealed, Marley treats the small gap left by normal eaves construction as enough, so long as the conditions of its UKAS certification are met in full. Old timbers dislike trapped damp, so on a frame this small detail gets measured and photographed.
On lifespans, Marley says the BRE's 60 years as a minimum life expectancy is a clay tile figure only. HomeBuilding gives clay tiles "60-80 years". For concrete the sources part company: Marley expects tiles "to last for around 60 years", while HomeBuilding puts plain concrete tiles at "40-50 years". We name both, since they come from two different sources, and neither tells you what your own roof will do.
Weight is the other thing a frame cares about. AD A, paragraph 4.4, says: "A significant change in roof loading is when the loading upon the roof is increased by more than 15%." A swap from clay to a heavier covering can cross that line, which means Building Regulations approval, and before anything is ordered the rafters and wall plate need a structural check.
At the survey we open the covering at one sound place, photograph the battens and underlay beneath it, and walk the verge where the covering meets the gable timbers. You receive the pictures with the findings, and the written total follows. Our pitched roofing page lists the coverings we fix and replace.
Under a Pencombe covering
- Battens
- Spacing and condition along every course
- Underlay
- HR or air-permeable, and the state of its laps
- Eaves gap
- 25mm to 15 degrees, 10mm above, with HR underlay
- Verge
- Bedding and edge units where roof meets gable
- Frame
- Any gap between the timbers and the covering
On a frame that has been shifting since the 1600s, verge and covering are read together.