Roofers in Knighton on Teme

Roof repairs and re-roofs in Knighton on Teme, for houses, farmhouses and farm buildings.

Defects are photographed from the high points down, and each one can be checked by you on screen or on paper.

Get a free quoteCall 01432 610152

A Grade I church and listed farm buildings

  • Older cottages with weathered clay tile roofs and brick chimneys behind a flint wall
    St Michael's churchSt Michael's church holds a Grade I listing, under list entry 1167609.
  • Slate roofs and chimney stacks along a red brick Victorian terrace
    Hilltop FarmhouseHilltop Farmhouse is listed Grade II, under list entry 1081424.
  • Newer homes with grey concrete tile roofs along a curving estate road
    A listed barn and stableA barn and stable 9 metres west of the farmhouse are Grade II too.

Mapping Knighton on Teme

Knighton on Teme on a street map, with a dashed circle around the town and the nearest towns we cover. Tiles © Esri; map data © Esri, HERE, Garmin, OpenStreetMap contributors.

Knighton on Teme roofs, church to barn

Church, barn and gutter: three callouts on a Knighton on Teme roof

We begin at the Grade I church walls and the listed farm group beside them, move to the long barn and stable roofs, and finish at the eaves, where gutters decide whether the walls stay dry.

A drawn cut-away section through a Herefordshire border house: the front of the main roof is cut open to show the rafters, underlay, battens and slates, beside a black-and-white timber-framed gable. Numbered, from the ridge down: 1 Church and farm group; 2 Barn and stable roofs; 3 Eaves and gutters.

Fig. 1 A Knighton on Teme roof cut open to show three callouts.

Callout 1 of 3

St Michael's church, Maes Court and Hilltop Farmhouse

On a listed group the walls come first. St Michael's church in Knighton on Teme holds a Grade I listing (list entry 1167609, dated 18 April 1966). Maes Court is Grade II (list entry 1081425, dated 6 October 1952), and so is Hilltop Farmhouse (list entry 1081424, dated 27 February 1986). A barn and stable about 9 metres west of the farmhouse are Grade II as well (list entry 1167654). Each entry is a separate question about what its roof may be given. The covering on each is established on site, never assumed, and every building gets its own photograph set and numbered notes, kept apart in the report.

Because St Michael and All Angels is a Church of England church, any roof job there goes before the diocese's faculty system, and the council's listed building consent is not the route while worship continues. Closure would change that. The photographs and written scope from a survey are made to travel with the faculty application.

The houses are different. Section 7 of the Planning (Listed Buildings and Conservation Areas) Act 1990 bites on works that would change a listed building's special interest, so a repair matching the existing covering and a switch to another material go to Malvern Hills District Council as separate questions. SPAB's advice on matching old stone or slate is to put any claim of unavailability, or any long delivery time, to the quarries themselves, and that check comes before we suggest a change. The survey pictures can go in with any application, which saves a second visit to the roof.

Malvern Hills District Council holds the list of conservation areas, so check whether your address appears there before you plan any work. On Article 4 directions, the council states: "At present there are no Article 4(2) Directions in force in Malvern Hills District Council." Our listed and heritage roofing page deals with protected buildings in more depth.

Church roof, consent route

Does roof work on a Grade I church need listed building consent?

No, as long as services continue in a Church of England church: its roof work goes through the faculty system instead. Once a church closes, listed building consent from Malvern Hills District Council applies in its place, so the route is worth confirming at the start.

On a listed group, every roof is its own conversation before any tile is lifted.

Fig. 2 Wall abutments, drawn close

Callout 2 of 3

Barn and stable roofs: long ridges and wide slopes

A listed barn and stable stand about 9 metres west of Hilltop Farmhouse (Grade II, list entry 1167654), and they show how a farm roof differs from a house roof: a long, wide run with few breaks. A survey of one is a walk along a straight line. We stand at one gable and sight along the ridge for dips, then repeat the exercise along the eaves, because a sag shows as a change in the line well before it shows as a leak. A plain barn has few valleys or abutments, so the photographs concentrate on the ridge, the eaves and the verges, and the report lists them in that order for each building.

Long runs put steady strain on their fixings. We check the ridge capping and every verge, look up from inside for daylight and for stained rafters and boards, and count slipped, cracked or missing pieces slope by slope. Sheeted roofs get their fixings and laps inspected. Tiled and slated ones get their battens and nails inspected once a few courses have been lifted.

Outbuilding roofs of corrugated sheet can be asbestos cement. HSE draws the line at the year 2000: if the building predates it, or was refurbished before it, assume asbestos is there, and its A14 guidance says AC roofs are "always fragile". A fragile sheet will not carry a person, so the roof is judged from a safe position on the ground or within the building until a sample has been tested. Whole sheets taken off with care are non-licensed work. Sheets in a substantially damaged or broken-up state count as notifiable non-licensed work, and HSE advises a lockable skip for the waste.

A barn or stable may be a working building, so the survey notes where animals, machinery or stored feed need to be moved or covered, and where a lifting platform could replace a scaffold. When a roof is beyond repair, the report lays out three options: patch the worst bays, re-cover one slope, or re-roof the lot. Our commercial roofing page covers barns, units and farm buildings.

Checked along a barn or stable roof

  • Dips in the ridge and eaves lines
  • Fixings and laps on sheet coverings
  • Daylight or stained boards from inside
  • Cracked, slipped or missing tiles
  • Verge edges at each gable
Fig. 3 The slopes, drawn close

Callout 3 of 3

Farmhouse eaves: gutters, falls and downpipes

A gutter is the last part of the roof that the rain touches, and at Maes Court or Hilltop Farmhouse it protects listed walls. An overflowing gutter sends water down the face of the wall, where it stains the surface and soaks the joints. For the gutter itself, Brett Martin sets out the fall: "1mm for every 600mm" toward the outlet. Too little and water stands in the run; too much and it spills past the stop end. Rainwater that escapes at a failed joint can run behind the fascia and into the roof timbers, so a drip at a joint is treated as a roof defect and never as a minor one. Where the fascia board itself has gone soft, that is photographed and priced as part of the same job.

A spirit level goes along every gutter run, and we photograph wherever water lies. A joint that weeps, a bracket that has pulled out of the board and an outlet choked with leaves are each marked on the picture. Falls are put right by moving brackets, not by packing the gutter with sealant, and a length that has cracked or sagged is renewed. If a scaffold is already up for other work, the gutters are examined from the platform, which gives a far closer view than a ladder. Photographs of the wall below show any damp staining that the overflow has left.

Boards at the eaves come next: the fascia in front and the soffit below. HSE's list of asbestos locations includes white asbestos insulating board soffit panels under roof eaves, and most removal of that board counts as licensed work. If a soffit on an older building looks like that, the job goes to a licensed firm once a sample has been tested.

At the foot of each downpipe we check that the gully or drain takes the flow, because a downpipe that discharges onto a footing wets the base of the wall. A gutter replacement on a house with a long run of eaves can be done in sections, working round the building in the order that suits the weather and the access. Our guttering, soffits and fascias page covers the options.

A gutter is checked with a level and a camera, because water standing in it shows up on both.

A farmhouse gutter at the eaves

SoundEven fall to the outlet, joints dry, brackets tight
Needs workWater standing, a weeping joint, a bracket pulled free

Knighton on Teme roofs: listed barns, sheets, rules and scaffold

What must be settled before a listed barn and stable in Knighton on Teme gets roof repairs?

Works that would change a listed building's special interest need consent under section 7 of the 1990 Act, and a like-for-like repair is treated apart from a switch of material. Malvern Hills District Council hears both, and the answer shapes the programme. If new stone or slate has to be matched, SPAB suggests testing any claim that it cannot be had against the quarries. Survey photographs give the council something concrete to read, and they show whether the battens or rafters under the covering have rotted.

Is it safe to walk on an old sheet roof on a Knighton on Teme outbuilding?

Not until the material is known. HSE's A14 guidance uses one word for asbestos cement roofs, "always fragile", and a sheet that looks sound can still give way underfoot. A building built or refurbished before 2000 is assumed to contain asbestos. The first look comes from outside at ground level and from within the building, and a sample is tested before anyone steps on the sheets. The report then names the material that was found.

What do guides give for taking an asbestos roof off a garage near Knighton on Teme?

MyJobQuote's asbestos figures are around £2,750 on average for a roof, and around £1,200 for survey and removal on a 20 m² garage roof; its average garage roof replacement in 2026 runs from £750 to £3,500. Those are UK figures for other garages. The written price would be one total, issued after the survey and the lab result, and it would say what happens to the sheets that come off.

Who checks a re-roof in Knighton on Teme for Building Regulations?

A Knighton on Teme address falls under South Worcestershire Building Control, which Malvern Hills District Council, Worcester City Council and Wychavon District Council run in partnership. You may use a registered building control approver instead; in England these firms are on the Building Safety Regulator's register, which has run since 6 April 2024. Whichever you pick, the question goes in first, before the work starts.

Does a homeowner in Knighton on Teme carry CDM duties on a roof job?

Under regulation 7(1) of the CDM Regulations 2015, a homeowner's client duties move across to someone else: the sole contractor, or, where more than one contractor is on site, the principal contractor, or the principal designer when both parties agree it in writing. On a sole-contractor job, regulation 15(5) has that contractor draw up the construction phase plan. The VAT domestic reverse charge works between CIS businesses and never reaches a homeowner, whose bill carries on as before.

Who deals with the scaffold licence for a Knighton on Teme road?

The Highways Act 1980, section 169, makes a licence necessary for scaffolding that blocks a highway. Worcestershire County Council's own wording is that the company hired for the job is "required to apply", and that same council charges £85 per week, then £65 for subsequent weeks. The county's page asks for applications in good time and reviews them on working days, Monday to Friday, so the licence goes into the programme from the start.

Request a Knighton on Teme roof survey

Name the road or the building and what worries you about its roof, and the survey will be planned around it.

10-year workmanship guarantee, in writing