Callout 1 of 3
Chimney stacks, pots and flashings on listed houses
Hopton Wafers has a listed manor: The Manor is Grade II (list entry 1383551, first listed 12 November 1954), and the house entered on the list as The Village is Grade II too (list entry 1383553, first listed 15 March 1974). On an older house the stack is the tallest part of the roof, and each of its four faces takes wind and rain. We study it from the ground with binoculars, then from the ladder, working down from the pots and cowls to the flaunching and the pointing. Flaunching is the mortar fillet around the base of the pots, sloped so that rain runs off it and away from the flues. A crack between the fillet and a pot lets rain into the flue, and pointing worn back from the face of the stack leaves joints that hold water.
Lead seals the line where the stack rises out of the slope. We examine the flashings, which are lead strips tucked into the mortar joints and lapped over the covering, then the back gutter behind the stack and the soakers, the folded pieces of lead that go under each course up the sides. Split or lifted lead is replaced and not sealed over. In MyJobQuote's words, correctly fitted lead flashing "can last for over 80 years", which is a reason to keep lead that is sound.
A stack that has leaned or lost its top courses is a rebuild and not a repair. We take it down to a sound level, keep the good bricks or stones for reuse and lay it back to the profile it had. On a listed house the shape and the material are agreed with the council first, so the stack on the skyline is the stack that goes back up.
After the visual check comes the hands-on one. We press a screwdriver tip into the pointing to find mortar that crumbles, tap the brickwork for hollow sounds, and rock each pot to learn whether its bedding still holds. A stack that looks sound from the lane can carry a loose pot or a hollow collar, and both are simpler to put right while the rest of the stack is still sound. Our chimney repairs hub covers rebuilding, repointing and capping in more depth, and the photographs we send show each face of the stack, including the faces nobody can see from the ground.
A Hopton Wafers stack, part by part
- Pots and cowls
- Cracks, loose bedding and blocked tops
- Flaunching
- The mortar fillet sloping water off the flues
- Pointing
- Joints worn back from the stack face
- Flashings
- Lead tucked into joints and lapped over the covering
- Soakers
- Folded lead under each course at the sides
Nothing on a roof is harder to see from below than the top of a chimney stack.















