Callout 1 of 3
Roof windows and a loft conversion's escape route
Start at the loft hatch. Before a roof window is priced we look at what the room under the slope could become: the headroom, the strength of the floor, the stair that will serve it, and the rafters that would be trimmed round the opening. A roof window is glazing set flush into the slope. A dormer is a box built out from it, with walls and a roof of its own, and it is a far bigger job. Alterations to the roof in England include a roof window, and the conditions that go with it are laid out in our planning guide for roof windows. A conservation area, such as the one Shropshire Council records at Culmington, weighs on dormers, and the guide lists the conditions on a roof window.
The glazing carries an energy figure of its own. In AD L 2021 Table 4.2 the figure for a roof window is 1.4, or WER Band B. A rooflight is a different product with a different figure, 2.2. For the existing roof round a loft conversion, Table 4.3 gives 0.35 as the threshold and 0.16 as the improved figure. From 24 March 2027 AD L 2026 renumbers these as Tables 3.2 and 3.3.
A conversion also has to let people out. Where a storey sits more than 4.5 m above the ground, AD B paragraph 2.5 offers two choices: a stairway protected by fire-resisting construction, or an upper storey divided from the rest of the house, with a separate exit of its own. Paragraph 2.23 offers sprinklers in open-plan layouts as another route. An escape window under paragraph 2.10 needs an openable area of at least 0.33m2, no smaller than 450mm by 450mm, with its bottom edge no higher than 1100mm above the floor, and it serves storeys within 4.5 m of the ground.
A conversion goes through building control as a whole, not window by window: structure, stair, fire safety and insulation are all looked at, either by the council's service or by a registered building control approver. The existing roof is examined first. Rafters, underlay and covering are checked before a window is cut into them, because a window set into a worn slope only moves the problem. Our skylights page covers fitting, flashing kits and trim.
Figures behind a Culmington loft window
- Roof window
- AD L 2021 Table 4.2: 1.4 or WER Band B
- Rooflight
- AD L 2021 Table 4.2: 2.2
- Existing roof
- Table 4.3: threshold 0.35, improved 0.16
- From 24 March 2027
- AD L 2026 Tables 3.2 and 3.3
- Escape window
- 0.33m2 and 450mm by 450mm minimum, per AD B 2.10
A roof window cut into a worn slope only moves the leak, so the slope is checked first.