Callout 1 of 3
Under the covering: underlay, eaves and air
Beneath the battens runs a layer that stays out of sight: the underlay, a membrane that catches whatever gets past the covering. Two kinds turn up on survey. High-resistance (HR) underlay does not let vapour through, while LR underlay is air-permeable. They behave differently in the roof space, and that difference decides how the eaves are treated.
For a cold roof lined with HR underlay, Marley sets a continuous opening of 25mm along the eaves where the pitch is 15° or less, and 10mm where the pitch is more than 15°. Where an LR underlay is paired with a ceiling that is sealed well, Marley accepts normal eaves construction at 3mm as enough ventilation, on condition that the UKAS third-party certification requirements are fully met. The underlay's own certificate is therefore read against the build-up of the roof, and the gap is checked rather than assumed.
BS 5250 is the code of practice that Approved Document C points to for condensation, and it is listed as current but under review. We take the practical lesson from it: a roof space needs somewhere for moist air to go, and a membrane or an insulation roll that blocks the way creates a problem of its own making.
From the loft we look for daylight where there should be none, for dark or damp patches on the underside of the boarding and for rusted nail tips. At the eaves we lift a short run of tiles or slates and photograph the edge of the underlay, the batten ends and the gap behind the fascia, since insulation pushed too far forward can close the very opening the roof relies on. If the underlay has split or slipped, the photographs show you where. Our roof inspections and surveys page sets out what each survey covers.
What follows depends on what the lifted tiles show. A split or slipped underlay can be re-laid in sections where the battens are sound, a blocked gap can be reopened, and a roof whose underlay has failed across a whole slope is the one that points toward a re-cover. The written total price follows the survey, and it says which of those the roof needs.
Underlay and eaves ventilation, as Marley sets it out
- HR underlay
- Not vapour permeable, so the eaves must stay open
- Pitch 15° or less
- 25mm continuous opening along the eaves
- Pitch over 15°
- 10mm continuous opening along the eaves
- LR underlay
- 3mm of normal eaves construction, with certification met
A roof needs somewhere for moist air to go, and the eaves gap is where we check it first.