In brief
A window energy rating is a band given to a window as a product, shown by the letters WER. Approved Document L gives a window, a roof window included, two ways to pass: a U-value of 1.4, or a band of B or better on the rating scale. England sets this in Table 4.2 and Wales in Table 4.1. The supplier's data sheet should show whichever figure the unit relies on, and the quote should name it.
The rating as Approved Document L uses it
Approved Document L does not ask you to understand how a rating is worked out. It asks you to hold one of two pieces of paper. England's Table 4.2, covering new fittings in an existing home, reads "1.4 or Window Energy Rating Band B minimum" against windows, and a note says that line includes roof windows and curtain walling. Wales words its Table 4.1 as "1.4 or minimum WER Band B" for a "Window or roof window".
The word minimum is the useful one. Band B is the lowest band that passes by the rating route, so a unit in Band B passes, and so does a unit rated better. A unit in a lower band can still pass if its U-value reaches 1.4, because the two routes stand side by side and either one will do.
That is all the Approved Document needs from you. Any further detail of how a band is scored belongs to the rating scheme that issues it, and the rating you rely on should be the one on the unit you are being sold.
How the rating sits beside a U-value
A U-value is a single measured property: the rate of heat loss through a square metre when the two sides differ by a degree. A lower figure loses less. A rating band is a summary figure given to a window product. The Approved Document treats the two as alternatives, which is why the table reads "or". Two units can therefore both pass, one on its U-value alone and the other on its band, and neither is preferred in the regulations. What matters to you is being told which route the unit on your quote relies on.
| Document | Window line | Rooflight |
|---|---|---|
| England, Table 4.2 | 1.4 or WER Band B | 2.2 |
| England 2026, Table 3.2 | 1.4 or WER Band B | 2.2 |
| Wales, Table 4.1 | 1.4 or WER Band B | 2.2 |
| Wales, Table 10.1 | 1.4 or WER Band B | 2.2 |
England's 2026 edition takes effect on 24 March 2027, and the new Welsh volume takes effect on 4 March 2027. Until then the older tables apply. The values in the window and rooflight columns match across all four rows, so a unit that satisfies one row satisfies the others as the table stands today. Only the roof figures differ between the two countries.
Questions for the supplier and the quote
Ask the person selling you a roof window three things. Which route does this product use, the U-value or the rating band? Where does the figure appear, on the data sheet or the unit's own label? Is that figure for the exact model and size on the quote? A band belongs to a specific product, not to a brand, so a vague promise such as "good energy rating" is not an answer.
If the quote is for a rooflight, the line is 2.2, and the rating question does not arise in the same way. That is why the first step is to say which kind of unit the quote covers. The guide to rooflights and roof windows sets out the difference, and the roof window U-value answer gives the figures for both countries.
Keep the data sheet with the quote and the photographs. Building control may ask to see it, whether that is the council's building control service or a registered building control approver, and a lost sheet is harder to replace than to keep. If the old unit still carries a label, we photograph that too, because it shows what was fitted before.
Windows, roofs and old fittings
In the Building Regulations 2010, "thermal element" means walls, floors and roofs only, with windows, roof windows and roof-lights excluded. So a window passes or fails on its own band or figure, whatever the roof around it achieves. The roof has its own number: 0.15 for a new roof in England and 0.13 in Wales, as the roof window U-value answer shows.
Wales adds a figure for fittings you keep. Table 10.1 gives threshold values for retained fittings of 3.3 for windows and 3.8 for rooflights. A window you are leaving in place is therefore measured against a looser limit than a window you are fitting, and it matters when an old window is staying where it is.
When we survey, we photograph the existing unit, read its label if it has one, and tell you plainly which route a replacement would use. Our price is one written total and names the product. The roof window energy rules guide goes through the tables in order, and Velux and skylights covers the whole range.