Roof window U-value

What U-Value must a roof window meet?

Part L gives a roof window two ways to pass and gives a rooflight its own looser figure. England and Wales print the same two numbers.

In brief

Fit a roof window to an existing home and the target is 1.4 W/m²K, or a Window Energy Rating in Band B. England sets that in Table 4.2 and Wales in Table 4.1. The 2.2 figure is for rooflights, a different category, so a quote that applies 2.2 to a roof window is using the wrong line. The slope around the window is checked against its own roof figure.

The target for an English home

In England, Approved Document L 2021 (with its 2023 amendments) has applied since 15 June 2022. Table 4.2 sets the new parts of an existing home at roof 0.15, window "1.4 or Window Energy Rating Band B minimum", and rooflight 2.2 W/(m²·K). A note beside the window row says it includes roof windows and curtain walling. That note puts a roof window on the window row; the rooflight row is a different thing.

A U-value counts the heat that escapes through a square metre of the building when the two sides differ by one degree, so a lower number loses less. The 0.15 belongs to the roof slope. Regulation 2 of the Building Regulations 2010 limits "thermal element" to walls, floors and roofs and leaves out windows, roof windows and roof-lights, so a window is tested separately from the roof it sits in. That is also why replacing a slate or tile covering does not by itself change what the window must achieve.

Until 24 March 2027 the 2021 tables apply. From that date Approved Document L 2026 renumbers them Tables 3.2 and 3.3, and Table 3.2 repeats the same roof, window and rooflight values.

The target for a Welsh home

Welsh volume 1 of Approved Document L, the 2022 edition with 2024 amendments, took effect on 23 November 2022 for use in Wales. Its Table 4.1, headed "Worst acceptable fabric performance values", sets limits for existing dwellings. Roofs must reach 0.13, "Window or roof window" 1.4 or minimum WER Band B, and roof-light 2.2. Table 10.1, which deals with windows and doors, restates "Windows, roof windows" as 1.4 or WER Band B.

The border only moves the roof. A brand new roof on an existing Welsh house must reach 0.13 where England asks 0.15. A renovated old roof falls under Table 11.1 instead: 0.16, and no worse than 0.35 where 0.16 cannot be reached. The window cut into either roof still answers to 1.4 or Band B, whichever country the house stands in.

Table 10.1 also carries threshold values for fittings you keep: 3.3 for windows and 3.8 for rooflights. A successor volume takes effect on 4 March 2027 for use in Wales, so the dates given here are the ones to check again in 2027.

Both countries in one table

Glazing reads identically in both countries, and only the roof rows move. Each figure is in W/m²K.

Existing dwelling, Part L values by country
ElementEnglandWales
Roof window1.4 or WER Band B1.4 or WER Band B
Rooflight2.22.2
New roof0.150.13
Renovated roof0.35 threshold, 0.16 improved0.16, worst 0.35

England's renovation row is Table 4.3, whose para 4.13 relaxes the target if upgrading cannot repay itself within 15 years. Wales uses Table 11.1, and para 11.14 triggers an upgrade of the whole element once more than 50 per cent of its surface is renovated; the tests are written for the roof, so they say nothing about a window. Neither renovation row is a figure for the window.

Four mix-ups are worth naming:

  • reading the rooflight row, the one marked 2.2, as if it covered a roof window
  • using the roof figure of 0.15 for the window itself
  • giving England's 0.15 to a new roof in Wales, which is held to 0.13
  • treating the 2026 edition as already in force, when it starts in 2027

Wording to look for on the quote

Ask which product goes in, and whether its data sheet gives a U-value, a window energy rating, or both. A unit rated at 1.4 or lower, or at Band B or better, satisfies the roof window requirement under both countries' rules. If a quote cites 2.2 for a roof window, ask why, because that is the rooflight number. Keep a copy of the data sheet with the paperwork, since building control may ask for it.

Ask, too, whether the opening keeps its size. Reusing the old opening is a different piece of work from cutting a new one, and it decides how much of the rafter timber is touched and how much of the surrounding covering is lifted. The roof window energy rules guide goes through the tables in more depth, and what a window energy rating is explains the band.

Our one written total price names the product and the opening, and we photograph the old unit as it comes out. Confirm the route with the council's building control service or a registered building control approver. The wider range is under Velux and skylights.

Related questions

Does the 0.15 roof figure apply to my new roof window?

No. A roof window takes the window line, 1.4 or WER Band B, in England and Wales alike, because the Building Regulations 2010 leave windows and roof windows out of the thermal element definition. The 0.15 in England and 0.13 in Wales are for the slope around it, and they apply to new roofs, not to the glazing.

Will the figures change when Approved Document L is reissued?

England's 2026 edition takes effect on 24 March 2027 and Wales's new volume on 4 March 2027. English Table 3.2 keeps the same values: 1.4 or WER Band B for windows and 2.2 for rooflights, so a unit chosen today should still comply. Ask building control which edition governs a job that straddles the change date.