A rooflight on a flat roof looks simple from the room below: a pane of glass in the ceiling. On the roof it is a small construction project. The glass sits on a kerb, a raised frame fixed to the deck. The waterproof membrane climbs the outside of that frame, and the climb is called an upstand. Every one of those four sides is a joint that rain meets from above, and every corner is a place where two upstands have to turn together.
Four subjects decide whether the result lasts: the height and build of the kerb, the way the membrane is dressed up it, the insulation value of the glass, and the paperwork. The paperwork differs by nation. England and Wales share a figure for the glazing, but they differ on the roof around it, on renovation, and on planning.
The sections follow the order of a survey visit. The wider picture is on our Velux and skylight installation page, and if you are still choosing a product, the guide on rooflights and roof windows compared sets the two apart.
What a kerb is and what it carries
A kerb is a small box frame, in timber or a similar material, built up from the roof deck and trimmed round the opening cut for the rooflight. It lifts the glass above the surface of the flat roof so that standing water, leaves and the thickness of the membrane cannot reach the joint between glass and frame. The rooflight then sits on top of the kerb, and the kerb takes its weight. The kerb is built square and level, because a unit set on a twisted frame will not close or seal evenly.
Some rooflights arrive with a ready-made upstand base fitted to the glass unit, and some are sold glass only, to be set on a kerb made on site. Either way the same chain of parts runs from deck to sky:
- the deck, the boarding or panel that carries the roof
- the trimmed opening, framed so the cut joists are supported
- the kerb, fixed to the deck round the opening
- the roof insulation, brought up to the kerb with no gap
- the membrane, dressed up the outside face of the kerb
- the glazed unit, fixed to the top of the kerb
A gap in any link shows up later as a stain on the lining of the light well. We look at the underside from inside the room before going on to the roof, because the marks tell us which link to open first.
Upstands: where the membrane climbs
The upstand is the part of the roof covering that turns up the kerb. On felt it is built from layers that are bonded up the face of the kerb. On EPDM rubber a sheet is folded at the corner and bonded. On GRP, the glass-reinforced plastic that is laid wet, the laminate runs up in one piece and is then topcoated. The method differs, but the aim is the same: no seam within reach of standing water.
The weak points are well known:
- the four corners, where one turn of membrane meets another
- the foot of the upstand, where it meets the flat roof surface
- the top edge, where the membrane stops and the glazed unit begins
- any fixings that pass through the membrane
The top edge is closed with a flashing, a strip of metal or the kit supplied with the rooflight, that laps over the upstand so water runs down and out. Lead is one choice here. In Royston Lead's cast-lead table, flashings (use B) are marked on Codes 4, 5 and 6.
Some old rooflights have no proper kerb at all, only a membrane laid flat against the glass frame. That joint has nothing to shed water, so it depends on sealant. Rebuilding it as a true kerb with an upstand is a different job from resealing, and the survey notes record which of the two the roof needs.
U-values: 2.2 for the glass, other figures for the roof
The thermal figure for a rooflight is the same in both nations. England's Approved Document L 2021, in Table 4.2, sets 2.2 W/(m²K) for a rooflight in an existing dwelling. Wales sets 2.2 in its own Table 4.1. A roof window has a different figure of 1.4 or WER Band B on both sides, so a unit sold as a roof window is not the answer on a flat roof when a rooflight figure is asked for.
The roof round the glass is a separate question. Under regulation 2 of the Building Regulations 2010, the thermal elements are the walls, floors and roofs, and windows, roof windows and roof-lights sit outside that group. So the rooflight is checked against 2.2, and the flat roof it sits in is checked against the roof figures. Those depend on the nation and on what the work is.
| Work | England | Wales |
|---|---|---|
| New roof | 0.15 (Table 4.2) | 0.13 (Table 4.1) |
| Renovated roof | 0.35 threshold, 0.16 improved (Table 4.3) | 0.16, not worse than 0.35 where 0.16 is not feasible (Table 11.1) |
| Next edition starts | 24 March 2027 | 4 March 2027 |
Both Approved Documents list renewing the flat-roof waterproof layer as renovation work. If we re-cover the roof as well as fit the rooflight, the insulation question comes with it, and our guide to roof window energy rules covers how the figures are read.
Falls round the kerb and standing water
A flat roof is not flat. It is built with a slope towards an outlet or gutter, and a kerb stands in the way of that run-off. Water that cannot get round it collects on the high side, against the upstand, which is the worst place for it to sit.
BS 6229:2025 is the standard for flat roofs whose waterproof coverings are flexible and fully supported. The NFRC says it sets "a minimum 1:80 finished fall for general roof areas and internal gutters". IKO advises designing for a fall of 1:40, set against the finished figure of 1:80, which is a different number for a different stage of the job. The standard covers membranes, not lead, so a lead-lined kerb falls outside it. BS 6229:2018 was withdrawn on 16 December 2025.
For a rooflight, the fall matters in three ways:
- the kerb should not sit in a dip, where water collects on every side
- on the high side, the water needs a way round the kerb, so the build may need a small sloping section to guide it round
- the outlet must be clear, so the fall has somewhere to go
Where a roof already holds water at the kerb, adding more sealant does nothing for the cause. The cure is to change the fall or to move the water, and that can mean re-laying the deck surface. A survey measures the fall with a level and photographs any pool, so you see it for yourself before a repair is priced, and we explain what the level showed in plain words.
Planning and approval on each side of the border
Fitting a rooflight to a house is planning territory as well as Building Regulations territory. In England, a rooflight is an alteration to the roof of a dwellinghouse under Class C of the 2015 Order, which means it is normally permitted development. The limits include a 0.15 metre projection and no part higher than the highest part of the original roof, so a tall kerb is a point to raise with the council before the order goes in. Conservation areas and National Parks do not bar Class C in England, but a listed house needs listed building consent as well. For a listed house the consent comes first in both nations, because works that touch its special interest need consent, under section 7 of the 1990 Act in England and section 88 of the 2023 Act in Wales.
In Wales, the 1995 Order as amended there removes the right to insert roof lights where the house is on article 1(5) land or inside a World Heritage Site, so a flat-roof rooflight in a Welsh conservation area or in the Bannau Brycheiniog needs planning permission. Elsewhere in Wales, the limit is 15 centimetres. Flats have no householder permitted development rights on either side.
For the Building Regulations, the Welsh Government says approval "will generally be needed for the installation of a new rooflight". Before cutting, we ask the council's building control team or a registered building control approver, in whichever nation the house stands. For a like-for-like unit the route is shorter, and the guide on swapping an old roof window sets it out.
Lifespans, costs and what the survey records
The rooflight and the membrane around it age at different rates, so the survey records both. Published membrane lifespans disagree, and each source keeps its own hedge. HomeBuilding gives EPDM as 25 to 30 years and GRP as 25 to 30, while Less gives EPDM as 30 to 50 years and GRP as 25 to 40. Felt runs from 10 to 15 years with HomeBuilding and 10 to 20 with Less. Treat them as rough ranges, not promises, and none of them measures your roof.
On cost, Checkatrade's repair guide gives rooflight replacement, for example a Velux, as "from £1,000". Which? prices a felt covering for one single garage of 6m x 3m at £1,400 to £3,500 (November 2025 survey, ex VAT). Our quote is a single written figure after the survey, and any quote, ours included, should spell out whether scaffold and VAT are in the price. What moves the price:
- opening size and kerb height
- whether the old kerb can be kept or must be rebuilt
- the covering: felt, rubber or fibreglass
- access to the roof
- how much of the roof must be re-covered at the same time
At the survey we check the kerb condition, the upstand corners, the fall and the outlet, with photographs of each. If the answer is a repair to the kerb joint, that is what we quote. Replacement of the whole roof is offered only when the covering around the kerb is worn out.