In brief
Condensation forms when moist air produced by cooking, bathing, laundry and breathing rises into the loft and meets cold timber, underlay or felt. Three faults make it worse: gaps in the ceiling that let the damp air up, blocked or missing ventilation at the eaves, and insulation or spray foam that changes how the roof dries. Condensation is a different problem from a leak, and the fix is different too.
How a warm house puts water on a cold roof
Every household adds moisture to its air: a shower, a boiling pan, a rack of washing, even sleeping. Warm air carries more moisture than cold air, and it rises. It slips through the gaps in a ceiling, round the loft hatch, around downlighter holes and along pipe and cable runs, and arrives in a roof space that is as cold as the weather outside.
The moment that air touches a surface colder than itself, the moisture drops out as water. The cold surfaces in a loft are the underside of the roof covering, the felt or underlay, the rafters, the nail points that poke through and the metal of any bracket or tank. In a hard cold spell you can see it as a film of droplets, and over weeks it feeds black mould on timber and soaks the insulation.
That sequence explains the usual pattern: damp that shows up in winter, drips from nail tips, a musty smell on opening the hatch, and no stain on the ceiling that lines up with a missing tile. If the mark follows a ridge, a valley or a chimney, look for a leak instead.
Underlay, eaves ventilation and what Marley sets out
How a roof gets rid of that moisture depends partly on its underlay, the membrane beneath the covering. Marley, a tile maker, separates two cases for a cold roof, where the insulation sits on the ceiling joists and the loft above stays cold.
| Underlay | What Marley says |
|---|---|
| High resistance (HR) | Not vapour-permeable; 25mm along the eaves for pitches of 15° or less, 10mm for pitches over 15° |
| Air-permeable (LR) | With a well-sealed ceiling, ordinary eaves construction (3mm) can supply the ventilation, so long as the UKAS certification conditions are satisfied |
So an HR underlay with its eaves vents blocked is a typical setup for trouble, while an LR underlay relies on a tight ceiling instead. BS 5250, the British Standard on moisture in buildings, is the current edition and is marked as under review.
The rule books differ by nation. In England, Approved Document C (2013) meets its condensation requirement by pointing to clause 8.4 of BS 5250:2002 and BS EN ISO 13788:2002. For a Welsh address, ask the council's building control service or a registered building control approver which approved document applies, because Wales has its own documents.
Insulation, spray foam and blocked eaves
Insulation helps in one way and hurts in another. Thicker insulation keeps more heat in the house, which is good, but it also leaves the loft colder and drier at the surface only if the air can move. Stuffed hard into the eaves, it closes the gap that Marley's table depends on. A cheap fix is to hold the insulation back from the eaves with a baffle that keeps an air path open.
Spray foam changes the picture more. Spray foam comes in two kinds, closed-cell and open-cell, and the Energy Saving Trust sorts them by how vapour behaves: closed-cell does not let it through, open-cell lets more through. Whichever is used, foam on the roof's underside partly seals the timber beneath. Rot can follow, and the Trust adds that the danger of it should be much lower where the foam is open-cell. Foam is also a matter for your mortgage provider, since RICS advises checking whether a lender allows it.
Neither material is wrong everywhere. What matters is how it was fitted to your roof. Our page on what a loft inspection shows lists the signs we look for in a loft that has been foamed or insulated.
What we check and what can fix it
On a loft survey we look at the evidence, photograph it and then decide whether the cause is moisture from below, a leak from above, or both. A visit is not a lab test, but the pattern of marks, droplets and mould can point one way. The checklist runs from the hatch outward:
- droplets or staining on nail tips and the underside of the underlay
- black mould on rafters, and its pattern
- whether insulation is pushed into the eaves
- gaps round the hatch, pipes and light fittings
- where extractor fans and the tumble dryer vent to
The fixes follow the cause. Seal the ceiling and hatch, send extractor fans outside rather than into the roof space, keep the eaves open with baffles, and leave the underlay type in mind before adding vents. A leak, by contrast, needs a repair at the roof covering, and a tile, a flashing or a valley is then renewed on that part of the roof.
Read the main page on roof inspections to see how a survey is run, or our answer on how old your roof is. A repair price is given in writing once we have seen the loft and the roof.