Short answer
Brett Martin, a gutter manufacturer, advises "1mm for every 600mm" of run, falling towards the downpipe or outlet. That is a very slight slope, close to level to the eye. With too little fall, water stands in the gutter, and a steep slope is not needed. Flat roofs and internal gutters are a separate case with a standard of their own.
How slight a gutter fall really is
The fall is the difference in height between the two ends of a length of gutter. Brett Martin's guidance for fitting guttering sets 1 mm lower for every 600 mm along the run, towards the outlet. Across a metre of gutter, the drop is under two millimetres, which is thinner than a coin. The same slope over a whole house frontage is still only a few millimetres, so a single bracket out of line shows.
So a fall cannot be judged by eye from the ground. A run that looks level can be draining, and one that looks sloped can be backing up. A spirit level held on the gutter bottom, or a line pulled tight from end to end, tells you more than a glance does.
The fall always runs towards an outlet. An outlet in the middle makes both halves slope toward it, while an outlet at one end makes the whole length slope one way. Where two lengths meet at a union, the fall has to carry across the joint without a step, otherwise water pauses there and the joint carries the weight of it.
When the fall goes wrong
A gutter that was hung correctly can lose its fall. The causes sit in what holds it up, not in the gutter itself.
- a bracket pulled out of soft fascia timber
- a span between brackets too long for the load
- a fascia board that has dropped or twisted
- weight from leaves, moss or a nest sitting in the run
- an earlier repair that set one length a little too high
The signs are standing water in the gutter after rain has stopped, green growth along the bottom, and a stain on the wall under the lowest part. Our gutter falls and alignment page covers realigning a run, and our sagging gutter page covers the brackets.
More fall is not better. A steep run looks wrong under the eaves, and in a downpour the water can shoot past the outlet instead of dropping into it. The aim is a slope just great enough that the run empties, and no more than that.
Take a photograph from the side with a taut string alongside, and a dip shows up against the line.
Flat roofs and internal gutters follow a different standard
The 1 mm in 600 mm figure belongs to a rainwater gutter hung on a fascia. A flat roof is built differently. BS 6229:2025 is the current standard in both countries for flat roofs, and for curved roofs no steeper than 10 degrees, that carry continuously supported flexible waterproof coverings. The National Federation of Roofing Contractors reports that it sets "a minimum 1:80 finished fall for general roof areas and internal gutters".
IKO, a membrane maker, advises designing for 1:40 so that a 1:80 finished fall is reached. That is IKO's advice, not the standard's wording. The older BS 6229:2018 was withdrawn on 16 December 2025.
The standard covers membranes only, not lead, and it does not apply to a half-round plastic gutter on a house. The two figures must not be swapped, because 1:80 is a far steeper slope than 1 mm in 600 mm. Our flat roofing pages deal with falls on membrane roofs, where the slope is built into the deck and measured on the finished surface, not on the gutter.
Checking and correcting a fall on your own house
Pour a bucket of water into the highest end on a dry day and watch it travel. The flow should reach the outlet steadily and leave nothing behind. Standing water is the clue, and it means either the fall is wrong or the run is dirty.
Do not climb to do it. A ladder against a gutter loads the brackets and can bend them. We survey from safe access, photograph the run, and note where the fall is lost, so you see what we saw.
Correcting a fall means re-fixing the brackets in a line, which is quick when the fascia is sound and slow when it is not. A level and a straight batten laid in the gutter bottom do the same job as water if you prefer to test the run dry. If the board is rotten, new brackets have nothing to grip, so the board is dealt with first. Our quote follows the survey as a single written total, and the guttering, soffits and fascias page lists what else sits on the roofline.
Before we leave, the fall is set again and tested with water. A run that passes that test is the only proof that counts.