A gutter looks level from the garden, and that is part of the trouble. It is not meant to be level. It is meant to tilt very slightly towards the outlet, so that water travels along the run instead of standing in it. The tilt is called the fall, and it is small enough that the eye cannot judge it and an ordinary spirit level can mislead.
When the fall is missing or has reversed, water settles in the low spot, carries silt with it, and spills over the front lip on the first heavy rain. The same thing happens when the gutter sits too high or too low against the roof edge, so that tiles drop water short of it or behind it. Owners can call a gutter like this blocked, and clearing it brings only a short reprieve.
This guide sets out the fall the makers give, the places a gutter tends to spill and what each one points to, how the roof edge and the gutter must line up, and how a flat roof differs. It belongs to our guttering, soffits and fascias service, and nothing in it changes when the address moves from Herefordshire into Monmouthshire or Powys.
The fall a gutter needs and its source
For gutters on a pitched roof, the figure to hold on to comes from a manufacturer. Brett Martin, a maker of gutter systems, gives a fall of "1mm for every 600mm" in its installation advice. It is a maker's guidance for fitting its own product, not a statute, and it is a sound starting point for a gutter in England and for one in Wales, since nothing sourced here changes it at the border.
Over a run of six metres, that fall puts the high end about a centimetre above the low end, roughly the width of a finger. On a shorter run the difference is smaller again. This is why the eye cannot judge it, and why whoever fits a gutter has to work from a string line or a water level rather than from how it looks against the roof.
Two things follow from so small a figure:
- a bracket set a few millimetres out can turn a draining run into a standing one
- a fascia that has moved or rotted unevenly can undo a fall that was right when the gutter went up
The fall also has to run towards an outlet. A run with an outlet at one end falls one way. A run with an outlet in the middle falls from both ends towards it. Work out which kind of run you have before deciding which way a section is wrong.
Reading an overflow: where the water leaves
The position of the spill is the best clue to the fault, because it tells you where the water was standing. Watch the gutter in heavy rain from a safe spot, or pour a bucket in at the high end on a dry day and note where it goes.
| Where it spills | What it points to | What we check |
|---|---|---|
| Along the middle of a long run | A sag between two brackets | Bracket spacing and the line of the fascia |
| At the stopped end | A fall running the wrong way | The height of each end against the outlet |
| Just above the outlet | A blocked or restricted outlet | The outlet, the downpipe and the drain below |
| At a joint between lengths | A perished seal, or two lengths set at different heights | The clip, the seal and the alignment either side |
| At an internal corner | Two flows meeting in one corner piece | Whether the corner can carry the load |
A spill at the outlet can look like a gutter fault when the real trouble sits further down, in the downpipe or the drain at its foot. A pipe that is full of silt or a drain that has backed up leaves the gutter nowhere to empty, whatever its fall. A bucket test, run from the high end while someone watches the foot of the pipe, shows quickly whether the water leaves as fast as it arrives.
If a gutter overflows even though it is clear and falls correctly, the volume reaching it may be more than one outlet can pass. That calls for a survey of the whole roof and the whole run, not another clear-out. Our guide to downpipes, hoppers and drains follows the water on from the gutter to the ground.
Where the gutter sits against the roof edge
A gutter that falls correctly can still miss the water. The roof must discharge into it, and that depends on the position of the bottom tiles, the underlay and the gutter itself. The lowest course of tiles should overhang far enough to drop water into the middle of the gutter, and the underlay at the eaves should run down into it rather than finish short of it.
A well-fitted gutter has its back edge higher than its front lip. If it ever overflows, the water then spills outwards, away from the wall and the eaves timbers, and not backwards into them. A gutter set the other way round sends overflow into the fascia and the soffit, where the damage is hidden until it is serious.
When the gutter sits too far from the wall, or too low, water runs off the tiles and lands behind it. When it sits too high, it can catch the tiles and hold them up. Both leave the gutter empty on a day when the wall below it is soaked.
- A gutter set too low or too far out receives only the fringe of the flow.
- A gutter set too high may catch the tile edge and hold it up.
- If one end of the run has sunk, its position against the tiles shifts along the whole length.
An eaves protection tray is a shaped strip that supports the underlay at the edge and carries water into the gutter. Our answer on why fit an eaves protection tray under the bottom tiles explains how one works.
On a stone-tiled or old slate roof, the eaves can be irregular, and the gutter may need to follow a wavy line. We fit to the roof as it stands, not to a ruler.
Brackets, fascias and why a gutter sags
A gutter holds its fall only while its fixings hold. Plastic and aluminium runs rely on brackets screwed to the fascia board or to the rafter ends, and cast iron relies on heavier brackets, or on hooks set into the wall or the stone. Weight from wet debris, ice and a loaded ladder all test them.
When a run starts to sag, the cause is one of these:
- brackets spaced too far apart for the weight the gutter carries when full
- brackets that have loosened in softened fascia timber
- a fascia board that has curved outwards away from the rafter ends
- a gutter that was fitted without a proper line, so the fault was there from the start
A loose bracket in sound timber is a simple repair. A bracket that will not hold in soft timber means the board is the problem, and hanging a new gutter on it only repeats the fault a season later. Our guide to capping or replacing fascias covers that decision.
Cast iron brings its own version of the problem. A full run is heavy, so a bracket that has worked loose lets a long section drop at once, and the joints between lengths open as it goes.
- Rotted timber around an old fixing needs sound wood cut in.
- A hook set in stone or brick may need re-bedding.
When we survey a run, we sight along it from both ends, check each bracket by hand, and photograph any section that has dropped. You see the pictures, with the section marked, before any route is agreed.
Flat roofs and internal gutters: a different fall
Not every gutter hangs from the front of a pitched roof. A flat roof can end in a box gutter inside the roofline, and a parapet roof can drain through an internal gutter lined with the same membrane as the roof. These need a fall too, and the figure is different from the one for a hung gutter.
NFRC says BS 6229:2025 sets "a minimum 1:80 finished fall for general roof areas and internal gutters". In England and in Wales the standard is the same, and it covers flexible waterproof membranes on flat roofs, not lead. IKO, a manufacturer, advises that a designer aiming at a 1:80 finished fall should draw the roof at 1:40. The first figure is a minimum measured after the roof is built, and the second is IKO's advice for the drawing board.
A box gutter that holds a pool after rain may therefore have a build fault, not a blocked outlet. A scoop clears the silt, but the pond returns until the fall is put right. Our flat roofing page covers flat-roof falls and membranes in full. Standing water in an internal gutter also loads the membrane and its seams. Where we see it, we photograph the pond, measure the depth where we can and show you the pictures before talking about the repair.
A box gutter differs from a hung one in how it is reached, and two checks matter most:
- access from the roof or from a window, since there is no ladder position outside
- the outlet at its low end, where leaves and grit settle and a partly blocked outlet turns a small fall into a standing pool
Putting a gutter right
What happens next is set by the survey. A loose bracket is refixed. A sagging section is lifted back to line on new brackets. A reversed fall means taking the run down and refitting it from the outlet outwards, setting a string line first. If the fascia has failed, the board comes first.
Options, from the lightest touch to the heaviest:
- re-seal or re-clip a joint that has shifted
- refix brackets and lift a sagging section back to its line
- refit a run on a new string line, keeping the gutter, if its condition allows
- replace the gutter and treat the fascia behind it as part of the same job
Replacement is offered only where the gutter itself is the problem. A run that is sound but badly hung is refitted on a new line, and the quote describes it as that.
You get the photographs, the run marked up and one written total price. Check whether any quote you hold states if VAT and scaffold are included. For rough scale, MyJobQuote lists an average of £1,000 to £1,600 for a new gutter set in the UK in 2026, a figure that moves with length, height and material.
Refitting also gives a chance to deal with the small things around the run: a stop end that has pulled off, a union bracket that was never fitted, a downpipe that no longer lines up with its outlet. Each is photographed where it is found, so that what the quote covers matches what you can see on the wall.