In brief
Water should run to a defined point: an edge gutter, a gutter set inside the roof edge, or an outlet that feeds a downpipe. The finished fall has to carry it there. Under BS 6229:2025, NFRC reports a 1:80 minimum finished fall for the deck and for internal gutters, and Brett Martin advises 1 mm for every 600 mm along a rainwater gutter. After the downpipe, building control is the place to ask.
Three places the water can go
Every flat roof needs somewhere for rain to end up, and the choice shapes how the deck is built. There are three usual answers.
| Destination | How it works | Fall that applies |
|---|---|---|
| Edge gutter | The deck slopes towards one edge and sheds into a rainwater gutter fixed there | Deck 1:80 at least (NFRC); gutter 1 mm for every 600 mm (Brett Martin) |
| Internal gutter | A channel formed within the roof, for example against a wall or between two slopes | 1:80 at least, according to NFRC |
| Outlet | A fitting set into the deck that leads to a downpipe | Deck falls towards it, 1:80 at least (NFRC) |
The 1:80 figure is NFRC's reading of BS 6229:2025, which it applies to general roof areas and also to internal gutters. Brett Martin's gutter figure is far gentler because a rainwater gutter is a narrow channel and not a deck. A slope as shallow as 1 mm in 600 mm is enough to move water along a clear gutter. It would be far too little for a roof. A roof may combine two of these, such as a central outlet with an edge gutter on one side, and a quote should say which your roof has.
Choosing the side the roof falls to
The direction of the fall is decided by where a gutter or outlet can sit and where the downpipe can run. A few plain points guide us when we survey a roof.
- Water should leave across the lowest edge of the deck, away from any wall that rises above it.
- A gutter needs a clear route for its downpipe to a drain. A fall that points at a side with no route is a problem however well it is built.
- Outlets sit at the low point of a roof and need a surface that falls towards them from every side.
- Where a roof meets a higher wall, a short upstand turns the covering up, and the water is shed away from it, not into it.
On an existing roof we can read the drainage from the staining. Dark tide lines, a stripe of green growth or silt gathered in one corner show where water travels and where it stops. Our page on flat roof falls and drainage goes through the clues, and ponding water explains what a low patch does to the covering over time.
Outlets, gutters and what they cost to put right
A drain that fails can fail at the outlet or the gutter, and a blocked one can send water back onto the roof. We check the outlet grille and the gutter run for leaves, silt and moss, and for joints that have opened or brackets that have dropped, since a sagging run holds water instead of passing it on. Clearing is the lightest fix. A Which? survey in November 2025 gives £75 to £350, excluding VAT, for clearing out every gutter on the house.
Replacing the guttering is a bigger job. MyJobQuote, in a page updated on 20 October 2026, says the average gutter replacement costs around £1,000 to £1,600 in the UK, with standard uPVC at around £40 to £50 per metre. That per metre sum is the rate for a run of gutter. It cannot price a roof, so it is never multiplied up.
Where a roof has no workable outlet, adding one means cutting into the deck and routing a pipe. We discuss that with you after the survey, and you receive a single written figure with scaffold allowed for.
After the downpipe, and the rules in each country
Where the water goes once it leaves the roof is a drainage question, and it is one to put to building control. Rainwater that runs to a drain, a soakaway or a water butt each has its own considerations, and the council's building control service, or a registered building control approver, can say what suits your plot.
Changing a flat roof's fall or its outlets can go together with a new covering, and that is renovation. In England, Approved Document L (2021 edition) treats a fresh flat-roof covering as renovation, and its Table 4.3 sets 0.35 and 0.16. In Wales, Table 11.1 of the Welsh Approved Document L sets 0.16, with 0.35 as the worst acceptable figure.
On approval, the Planning Portal in England uses less than 25 per cent of the building envelope and less than 50 per cent of the roof, while gov.wales says that in Wales re-roofing will need Building Regulations approval in most situations. The flat roofing hub gathers every page on this subject, and what fall a flat roof needs covers the numbers in more detail.