01432 610152 Get a quote Call 01432 610152

Rooflight replacement

Replacing rooflight sheets on industrial roofs

A failed rooflight sheet lets in rain and leaves a hole in the roof surface. This guide covers matching the replacement, doing the work safely and what building control expects in each nation.

Horizon Roofing Hereford 9 min read

Replacing industrial rooflights is a routine repair on a sheet roof, and a place where a quick job goes wrong. The old sheet may have failed for a reason: age, sun, a cracked lap or a blow from something dropped. The new sheet has to fit the same wave as the metal around it, sit on the same purlins, seal at the same laps and carry daylight into the unit without leaking back out.

The work also puts a person beside a weak spot in the roof, where a fall is a real risk. A rooflight bay is a hole in the roof surface with a thin sheet across it, and it may be weaker than the sheets either side. The plan for the job begins with how to reach the bay safely, before any sheet is ordered.

This guide covers why rooflight sheets are replaced, how the new one is matched to the roof, how the work is done safely, how the fixing and sealing go, the position on asbestos and wildlife in older buildings, and the building control position in each nation. It belongs to our commercial roofing service, and you can read about the underlying risk in our guide to fragile roofs and rooflights.

Why a rooflight sheet needs replacing

Rooflight sheets are made of translucent plastic or glass-reinforced fibre, and they age differently from the metal beside them. Sunlight and weather cloud the surface and make it brittle. The sheet cracks at a fixing, splits along a lap or breaks under the weight of a person or a dropped tool. Our guide to why rooflight sheets go brittle covers the causes in detail.

The reasons an owner asks for a replacement:

  • rain coming through a crack or a split lap
  • a sheet that has gone dark, so the unit is dim underneath
  • fixings that have pulled through a brittle sheet
  • damage from a fall of debris, a ladder or a hailstone
  • a rooflight that was patched with tape or sealant and has failed again

Repair has limits. A crack can be sealed for a short time, but the sheet around the crack is the same age as the crack and can be as weak. When a sheet is brittle across its whole width, patching it only moves the failure along, and the replacement is the better buy. When one sheet in a long run has failed and the rest are sound, a single sheet may be all that is needed.

It is worth checking the sheets either side of the failed one. Rooflights of the same age can be close to failing together, and replacing one sheet while its neighbours are on the edge of failure can mean a second visit and a second set of access equipment within the year.

Matching the profile of the roof

A rooflight sheet has to match the profile of the metal sheets in the same roof. If the roof is corrugated, the rooflight is corrugated to the same pitch and depth. If it is trapezoidal, the rooflight has the same rib spacing and rib height. A near match leaves gaps at the laps, and a gap is a leak.

Before an order goes in, the survey records:

  1. the profile, taken as a measured section of the sheet, with the rib spacing and depth
  2. the sheet length from eaves to ridge, or the length of the run between laps
  3. the number of skins in the roof: a single skin, or a built-up roof with an outer sheet over a liner
  4. the thickness and finish of the surrounding sheets
  5. the type of fixings in use, and the purlin positions they go into

A built-up roof needs particular care. The rooflight in the outer skin has to line up with a rooflight in the liner beneath, or the light does not reach the unit. If the old rooflight was a double-skin unit with two translucent sheets, a single replacement changes how much light and heat it passes. The data sheet for the new sheet gives its details, and we check it against what the building needs before ordering.

If the old profile has been discontinued, an equivalent profile has to be found, or a run of the roof sheets adjusted, so that the laps line up. That is a question for the survey, not for the day of the job.

Reaching a rooflight bay safely

No rooflight bay should be relied on to carry weight. The Health and Safety Executive's warning that AC roofs are always fragile applies to cement sheets, and the same habit of mind applies to translucent sheets of unknown age. The plan for the job treats the bay as a hole, even when it looks like roof.

Ways to reach a rooflight bay, and when each suits
MethodSuits
Mobile access platform from belowClear floor space inside, or ground access outside
Boards on the purlinsSound steel either side of the bay
Edge protection and nettingAny bay near an eaves or gable edge
Temporary cover over the bayA cracked sheet awaiting replacement

Where the unit keeps working, the floor below is part of the plan. Stock, machines and people are moved or fenced off, because a sheet or a tool that falls goes into the unit. The exclusion zone is agreed with the site manager before work begins, and it stays in place until the new sheet is fixed.

The Construction (Design and Management) Regulations 2015 apply to this work for a commercial client in England and in Wales, and a construction phase plan covers it. That document names the access method, the fenced zone below and the people on site. We also ask the site manager to tell staff, so nobody goes under the bay or onto the roof while the work is in hand.

Fixing, sealing and finishing the new sheet

With the old sheet out, the purlins under the bay are inspected. A rooflight that has leaked for some time can leave wet timber or rusted steel beneath it, and any such fault is shown to the owner before the new sheet goes on.

The new sheet is laid to match the roof. The side laps sit with the same overlap and direction as the metal sheets; the end laps are made with a continuous bead of sealant, and the sheet is fixed through the crown or the valley, as the profile requires, with screws and sealing washers made for the job. Over-tightening can crack a plastic sheet, because the screw draws the sheet down hard against the purlin, so fixings are set to hold the sheet without crushing it.

The finishing checks:

  • every lap sealed along its full length, with no gaps at the corners
  • fixings in the positions the maker specifies, with no spare holes left open
  • the new sheet sitting flat, with no twist across the bay
  • a gap or flashing at the ridge and at any adjoining trim closed
  • the inside of the unit checked for daylight at the laps

After the work, the new rooflight sheet is photographed from the roof and from inside, and the photographs go to the owner with the written quote's reference. We leave the site clean, and the old sheet goes with us. Plastic and fibre sheets from a roof built or refurbished before 2000 are treated with caution until the material is known, which brings in the asbestos question.

Older buildings: asbestos and wildlife

HSE says that for any building built or refurbished before 2000, asbestos should be assumed present. On an industrial unit with cement sheets, the rooflights are set into those sheets, and replacing one means working at the edge of an AC panel. The fixings for the new rooflight are drilled into the purlin, not the AC, wherever the layout allows. Where the AC has to be cut or drilled, the job is planned as asbestos work, not as a rooflight swap. For the categories of work and where the waste goes, see our guide to asbestos cement sheet roofs on industrial units.

Barns and older sheds bring a second matter. A roof void can hold birds' nests and bat roosts. Section 1 of the Wildlife and Countryside Act 1981 applies where someone intentionally destroys a nest that is occupied or under construction. Bats are protected at their breeding sites and resting places, whether or not anyone intends harm: regulation 43 of the 2017 Habitats Regulations makes damaging or destroying one an offence.

Licences come from Natural England in England and from Natural Resources Wales in Wales. If a rooflight bay opens into a loft or roof void where a nest or roost may be present, the work is paused until the position is clear, and the owner is told what the licence route involves before any date is set for the sheet to go in.

Building control and consent: England and Wales

A like-for-like sheet swap looks routine, yet a new rooflight can count as building work, and the answer depends on the nation.

  • In Wales, the Welsh Government's rooflight page says approval under the Building Regulations is generally needed when a new rooflight is installed. Registered approvers are overseen by the Building Safety Regulator for the Welsh Ministers, and the Welsh Ministers regulate the councils' own building control teams.
  • In England, building control is a council service or a registered building control approver. Approvers have been registered with the Building Safety Regulator since 6 April 2024, though private building control itself is older than that.

The Building Regulations 2010 leave rooflights out of the group of thermal elements, so a rooflight has its own standard. For houses, the approved documents set rooflights at 2.2 W/(m²·K), but a unit is not a house, and building control names the figure that applies to a non-domestic building. Ask before the order goes in, because a rooflight in a repaired roof can fall under the same question as a new one.

A listed building or a converted barn adds consent. For a listed building in England the source is section 7 of the Planning (Listed Buildings and Conservation Areas) Act 1990; in Wales it is sections 88 and 89 of the Historic Environment (Wales) Act 2023.

The written quote is a single total after the survey. Four things set it: the access method, the number of sheets, how long the run is and the state of the purlins below.

Replacing rooflight sheets: questions

Can one cracked rooflight sheet be replaced on its own?

Yes, where the neighbouring sheets are sound. The new sheet is matched to the profile, laid with the same laps and sealed along its length. We check the sheets either side first, because sheets of the same age in a run can be near the end together, and a second visit means second access costs.

Do I need building control approval to replace a rooflight on a unit?

The answer depends on the work and the nation. In Wales, the Welsh Government's page says a new rooflight generally needs approval. In England, ask the council's building control team or a registered building control approver. We put the question to the right body first.

What if the rooflight sits in an asbestos cement roof?

Until a sample result shows otherwise, assume the roof is asbestos cement, and treat it as fragile. The new fixings go into the purlins rather than the cement sheets wherever possible, and any drilling or cutting of the sheets turns the job into asbestos work with its own plan and waste route.

Get your free roof quote

Tell us about the roof and we will arrange a survey.

10-year workmanship guarantee, in writing