What U-Value does a replacement roof need in Wales?

In Wales the new-roof figure is lower than the one across the border. A roof that is re-covered is renovated and read against a different table.

In brief

The Welsh table that fits is decided by whether the roof is new or renovated. Under the Welsh Approved Document L, Table 4.1 sets 0.13 (W/m²K) as the figure when a roof goes onto a house that is already built, while a renovated roof is read against Table 11.1, which asks for 0.16 and tolerates 0.35 where 0.16 cannot be reached. A rooflight must reach 2.2, and a roof window 1.4 or WER Band B. Building control confirms which table fits your roof.

Two Welsh tables and what each one is for

A U-value measures heat loss: how much energy leaks through each square metre of roof for every degree between the air inside and the air outside; the unit is W/m²K. A smaller figure means a roof that holds its warmth better, and a lower bill for heating the rooms underneath it. The Welsh Government's Approved Document L, volume 1, is the 2022 edition incorporating 2024 amendments, and it has taken effect for use in Wales since 23 November 2022. The roof figures sit in two tables.

Roof figures in the Welsh Approved Document L
WorkTableW/m²K
New roof in an existing dwelling4.10.13
Retained fabric, target11.1 (a)0.16
Retained fabric, limiting value11.1 (b)0.35

Table 4.1 is headed "Worst acceptable fabric performance values", so 0.13 is the worst figure Wales will accept for a roof that is new to the dwelling. Table 11.1 deals with retained fabric. Re-covering an existing roof is renovation, so it is read against Table 11.1, and the 0.13 figure does not apply to it.

When the whole roof has to be improved

The Welsh document ties the upgrade to how much of the roof is being renovated. Paragraph 11.14 says the whole element is to be brought up when the area renovated is greater than 50% of the surface of the element in question, or where the work counts as a major renovation. Below that share, a repair is a repair, and the roof is not drawn into an upgrade. The line between the two is a measured one, so a rough estimate from the ground will not settle it.

The Welsh Government's own re-roofing page is blunter about energy. It says roofs belong to the category the regulations call thermal elements, so re-covering should come with better insulation too. Flat roofs are caught as well, and paragraph 11.16 counts a renewed flat-roof membrane as a replaced layer.

Because the area decides the answer, the survey measures it. We photograph the roof, work out the share affected and write the figure down before the quote is fixed. Our page on re-roofing a house in Wales covers the approval side, and why Building Regulations approval is needed in most situations once a roof is being re-covered as a whole.

When 0.16 cannot be reached in Wales

Paragraphs 11.20 and 11.21 deal with a roof that cannot reach the column (a) figure. If 0.16 cannot be achieved at reasonable cost, or in practice, or on technical grounds, the roof is upgraded to the best standard that is feasible on all three counts. As a general rule, the thermal element should not end up worse than the limiting figure in column (b), which is 0.35.

The cost test asks whether energy savings recover the initial outlay inside 15 years. A roof that fails that test is still improved, but to a lesser figure, and the decision goes to building control. Our page on what to do if insulating the roof will not pay back sets the Welsh test beside the English one.

Where the case rests on a feature of the building, we photograph that feature on your own roof and put it before the council's building control service or a registered building control approver. The relaxation is then argued from what is physically there, which is what makes it hard to dispute. If the council asks for more detail, the same photographs and measurements go back to it unchanged.

Roof glazing, and the 2027 Welsh edition

Windows are kept separate from the roof. In Wales, a roof-light has 2.2 in Table 4.1, and a roof window has 1.4 or minimum WER Band B. Table 10.1 repeats those figures for replacement windows, and adds threshold values for retained fittings of 3.3 for windows and 3.8 for rooflights.

A new Welsh edition is due. The Welsh Government lists Approved Document L volume 1 as taking effect on 4 March 2027 for use in Wales, and until then the 2022 edition stands, so a job priced now is read against the figures above. Ask building control which edition it will apply if the application date is close to the change. Building control itself is also changing: new Welsh building regulations come into force on 1 July 2026, reforming the building control process and replacing the depositing of plans with applications for non-higher-risk work.

The job as a whole is on our page for roof replacement. Once the survey is done we give a single written total, and building control's view of which table applies is part of getting that price right.

Related questions

Is 0.13 the figure for a re-covered roof in Wales?

No. Table 4.1 gives 0.13 where an existing dwelling is given a new roof. A re-covered roof is renovation, read against Table 11.1: 0.16, and no worse than 0.35 where 0.16 cannot be reached. Building control confirms which table your own work falls under, so ask it before the price is agreed, and keep its answer in writing with the quote.

Do roof windows in Wales have a different figure from the roof?

Yes. Table 4.1 sets the roof window and roof-light figures out separately from the roof. The roof itself is a thermal element, and windows and roof-lights fall outside that definition in the Building Regulations 2010, so each window is rated by itself and not by the roof's figure.