In brief
Moist air from the rooms below gets into the roof structure, reaches a surface that is cold, and turns to liquid. On a flat roof that surface can be the underside of the deck or the covering. The damp shows as stains, drips on cold mornings or mould on the ceiling, with no rain involved. The cure is to stop the air getting up, give it a way out, or change how the roof is built.
How room air ends up wetting the deck
Cooking, bathing, drying clothes and breathing all put water vapour into the air indoors. Warm air holds more of it than cold air, so once that air touches anything cold, part of the vapour turns back into drops. Anywhere that surface is hidden from view, the drops soak in unseen.
In a flat roof the surface in question is the underside of the deck, or the underside of the covering where there is no deck. Air gets to it through gaps in the ceiling: around light fittings, loft hatches, pipes and the edges of plasterboard. A roof built as a cold deck has insulation beneath the deck and an air space above it, so the deck itself stays cold. A roof built as a warm deck has insulation above the deck, which keeps the deck on the warm side. The page on warm deck or cold deck sets out the difference.
The covering and the deck are not at fault in either case. The problem is that moist air has found a cold place to land, and the way the roof is layered decides whether that can happen at all.
Telling condensation from a leak
The two look alike from the room below, because both leave a stain. The pattern over time is what separates them.
| Clue | Condensation | Leak |
|---|---|---|
| Timing | Cold, still mornings | During or after rain |
| Where | Spread across the ceiling | Beneath one entry point |
| Surface | Mould, beads of moisture | Brown tide marks |
| Rain-free spells | Still appears | Dries out |
A table is a guide, not a diagnosis. A roof can have both at once, and a leak can run along a joist and show well away from where it came in. The page on why a flat roof leaks only sometimes deals with the intermittent kind.
On the survey we photograph the underside of the deck where it can be reached, check the insulation for dampness, and look at the ceiling for gaps that let air through. We also ask which rooms get steamy, because a bathroom with no fan sends a great deal of vapour towards the same few metres of ceiling. The flat roofing hub lists what each covering needs.
What the standards say, in England and in Wales
For England, Approved Document C (site preparation and resistance to contaminants and moisture) says the condensation requirement is met by following Clause 8.4 of BS 5250:2002 and BS EN ISO 13788:2002. BS 5250, the code of practice for controlling condensation in buildings, is listed by BSI as current but under review, so the edition AD C names is older than the one on sale.
For Wales, the Building Regulations are devolved and the Welsh Government publishes approved documents of its own, and each one carries the words for use in Wales. For a Welsh address we ask the council's building control service or a registered building control approver which condensation guidance applies, rather than assume it matches the English text.
Both sides meet at insulation. In England, adding insulation to an existing roof falls under Approved Document L, with Table 4.3 setting a threshold of 0.35 and an improved figure of 0.16 W/m²K. In Wales the equivalent is Table 11.1, which asks for 0.16 W/m²K and accepts no worse than 0.35 where 0.16 is not feasible. Thicker insulation changes where the cold surface sits, so the build-up has to be planned as a whole.
How condensation under a flat roof is put right
The cure follows the roof's construction, and the survey finds which of these applies:
- sealing the ceiling around light fittings, hatches and pipe entries, so less air gets up
- fitting or fixing extractor fans in kitchens and bathrooms so vapour leaves the house
- opening ventilation at the edges of a cold deck, where the design allows it
- adding a vapour control layer, a sheet below the insulation that slows air carrying moisture
- converting to a warm deck, with insulation above the deck, when a covering is renewed
None of these helps if the insulation is already soaked. Insulation that has been soaked holds moisture against the deck instead of keeping heat in, so it is replaced and not dried in place. Timber that has stayed damp for a long time is probed for softness before any new layer goes over it, and any boards that have lost their strength are cut out and renewed first.
If the covering is due for replacement anyway, that is the natural moment to alter the build-up. The written price comes after the survey and describes the layers it will leave, so you can see what the roof will be.